En-3
Aftertheleaktest,applyinsulating
materialtightlysothatthereis
nogap.
Whenthepipingistobeattached
toawallcontainingmetals(tin
plated)ormetalnetting,usea
chemicallytreatedwoodenpiece
20mmorthickerbetweenthewall
andthepipingorwrap7to8turns
ofinsulationvinyltapearound
thepiping.
Touseexistingpiping,perform
COOLoperationfor30minutes
andpumpdownbeforeremoving
theoldairconditioner.Remake
areaccordingtothedimension
fornewrefrigerant.
Morethan
100mm
Openasarule
Morethan500mm
ifthefrontandboth
sidesareopen
Morethan100mm
Morethan200mmifthereare
obstaclestobothsides
Openasarule
Morethan500mmiftheback,
bothsidesandtopareopen
Morethan350mm
1-5. INSTALLATION DIAGRAM
ACCESSORIES
Checkthefollowingpartsbeforeinstallation.
(1) Drainsocket 1
(2) Draincap 2
PARTS TO BE PROVIDED AT YOUR SITE
(A) Powersupplycord* 1
(B)
Indoor/outdoorunitconnectingwire*
1
(C) Extensionpipe 1
(D) Wallholecover 1
(E) Pipingtape 1
(F)
Extensiondrainhose
(orsoftPVChose,15mminner
diameterorhardPVCpipeVP16)
1
(G) Refrigerationoil
Little
amount
(H) Putty 1
(I) Pipexingband 2to7
(J) Fixingscrewfor(I) 2to7
(K) Wallholesleeve 1
(L)
SoftPVChose,15mminner
diameterorhardPVCpipeVP16
fordrainsocket(1)
1
Note:
*Placeindoor/outdoorunitconnectingwire(B)and
powersupplycord(A)atleast1mawayfromthe
TVantennawire.
The“Q’ty”for(B)to(K)intheabovetableisquantity
tobeusedperindoorunit.
Unitsshouldbeinstalledbylicensedcontractor
accordingtolocalcoderequirements.
Outdoor unit installation
Airinlet
169 500
Airinlet
4-10×21Ovalholes
396
Airoutlet
840
(Unit:mm)
361
330
1-6. DRAIN PIPING FOR OUTDOOR UNIT
Pleaseperformthedrainpipingworkonlywhendrainingfromoneplace.
1)Chooseoneholetodischargedrainandinstallthedrainsocket(1)tothehole.
2)Closetherestoftheholeswiththedraincaps(2).
3)ConnectthesoftPVChose(L)of15mmintheinsidediameteronthemarketwiththedrainsocket(1)andleaddrain.
Note:
Installtheunithorizontally.
Donotusethedrainsocket(1)andthedraincaps(2)inthecoldregions.Drainmayfreezeanditmakesthefanstop.
Theoutdoorunitproducescondensateduringtheheatingoperation.Selecttheinstallationplacetoensuretopreventtheoutdoorunitand/orthegroundsfrom
beingwetbydrainwaterordamagedbyfrozendrainwater.
100ormore
500ormore
100ormore
Servicespace
350ormore
350ormore
6. Service space
Providespaceforserviceandmaintenanceasshowninthegure.
• Wheninstallingtheunitinanareathatisenclosedwithwallssuch
asaverandah,besuretohaveenoughspaceasshownbelow.
Inthiscase,theairconditioningcapacityandpowerconsumption
mightdeteriorate.
• Whenthereisalackofairoworthereisapossibilityofbecoming
shortcycle,installanoutletguideandmakesurethereisenough
spacebehindoftheunit.
• Wheninstallingtwoormoreunits,donotinstalltheunitsinfrontor
behindeachother.
5. Obstacles in front, behind and on side(s)
200ormore
100ormore
350ormore
500ormore
500ormore
Heightoftheobstacleis1200orless
(Unit:mm)
BN79A289H01_en.indd 3 2016/04/20 14:52:58