Loading ...
Loading ...
En-2
3. Obstacles in front (blowing) only
Whenthereisanobstacleinfrontof
theunitasshowninthegure,open
spaceabove,behind,andonthesides
oftheunitisrequired.
2. Front (blowing) side open
As long as space indicated
in the figure is provided, it
is allowed to install the unit
where obstacles are behind
andon the sides of theunit.
(Noobstacleabovetheunit)
1-3. SELECTING OPTIONAL DIFFERENT-DIAMETER JOINTS
Ifthediameterofconnectionpipedoesnotmatchtheportsizeofoutdoorunit,useoptionaldifferent-diameterjointsaccordingtothefollowingtable.
Portsizeofoutdoorunit
Optionaldifferent-diameterjoints
(portsizeofoutdoorunit→diameterofconnectionpipe)
MXZ-2E52VAD MXZ-3E54VAD MXZ-4E71VAD Liquid/Gas
6.35(1/4)
9.52(3/8):PAC-493PI
9.52(3/8)
12.7(1/2):MAC-A454JP
9.52(3/8)
15.88(5/8):PAC-SG76RJ
12.7(1/2)
9.52(3/8):MAC-A455JP
12.7(1/2)
15.88(5/8):MAC-A456JP
Refertotheinstallationmanualofindoorunitforthediameterofconnection
pipeofindoorunit.
AUNIT 6.35(1/4)/12.7(1/2)
A-BUNIT A-CUNIT B-DUNIT 6.35(1/4)/9.52(3/8)
*1 Connecttothepowerswitchwhichhasagapof3mmormorewhenopen
tointerruptthesourcepowerphase.(Whenthepowerswitchisshutoff,it
mustinterruptallphases.)
*2 Usewiresinconformitywithdesign60245IEC57.Usetheindoor/outdoor
connectingwireinconformitywiththewirespecicationsspeciedinthe
installationmanualoftheindoorunit.
*3 Neverusepipeswiththicknesslessthanspecied.Thepressureresistance
willbeinsufcient.
*4 Useacopperpipeoracopper-alloyseamlesspipe.
*5 Becarefulnottocrushorbendthepipeduringpipebending.
*6 Refrigerantpipebendingradiusmustbe100mmormore.
*7 Insulationmaterial:Heatresistingfoamplastic0.045specicgravity
*8 Besuretousetheinsulationofspeciedthickness.Excessivethickness
maycauseincorrectinstallationoftheindoorunitandinsufcientthickness
maycausedewdrippage.
*
9
Iftheoutdoorunitisinstalledhigherthantheindoorunit,max.height
differenceisreducedto10m.
*
10
Ifpipelengthexceeds40m,additionalrefrigerant(R410A)chargeisre-
quired.(Noadditionalchargeisrequiredforpipelengthlessthan40m.)
Additionalrefrigerant=A×(pipelength(m)-40)
FREE SPACE REQUIRED AROUND OUTDOOR UNIT
1-4. SELECTING THE INSTALLATION LOCATION
• Whereitisnotexposedtostrongwind.
• Whereairowisgoodanddustless.
• Whererainordirectsunshinecanbeavoidedasmuchaspossible.
• Whereneighboursarenotannoyedbyoperationsoundorhotair.
• Whererigidwallorsupportisavailabletopreventtheincreaseofopera-
tionsoundorvibration.
• Wherethereisnoriskofcombustiblegasleakage.
• Wheninstallingtheunit,besuretosecuretheunitlegs.
• Whereitisatleast3mawayfromtheantennaofTVsetorradio.Opera-
tionoftheairconditionermayinterferewithradioorTVreceptioninareas
wherereceptionisweak.Anampliermayberequiredfortheaffected
device.
• Installtheunithorizontally.
• Pleaseinstallitinanareanotaffectedbysnowfallorblowingsnow.In
areaswithheavysnow,pleaseinstallacanopy,apedestaland/orsome
bafeboards.
Note:
Itis advisable to make a piping loopnear outdoor unit so as to reduce
vibrationtransmittedfromthere.
Note:
Whenoperatingtheairconditionerinlowoutsidetemperature,besure
tofollowtheinstructionsdescribedbelow.
• Neverinstalltheoutdoorunitinaplacewhereitsairinlet/outletside
maybeexposeddirectlytowind.
• Topreventexposuretowind,installtheoutdoorunitwithitsairinlet
sidefacingthewall.
•
Topreventexposuretowind,itisrecommendedtoinstallabafe
boardontheairoutletsideoftheoutdoorunit.
Avoidthefollowingplacesforinstallationwhereairconditionertrouble
isliabletooccur.
• Whereammablegascouldleak.
• Wherethereismuchmachineoil.
• Whereoilissplashedorwheretheareaislledwithoilysmoke
(suchascookingareasandfactories,inwhichthepropertiesof
plasticcouldbechangedanddamaged).
• Saltyplacessuchastheseaside.
• Wheresuldegasisgeneratedsuchashotspring,sewage,waste
water.
• Wherethereishigh-frequencyorwirelessequipment.
•
WherethereisemissionofhighlevelsofVOCs,includingphthalate
compounds,formaldehyde,etc.,whichmaycausechemicalcracking.
500ormore
200ormore
350ormore
100ormore
1. Obstacles above
Whenthereisnoobstacleinfrontand
onthe sidesof theunit, itis allowed
toinstalltheunitwhereanobstacleis
abovetheunitonlyifthespaceshown
inthegureisprovided.
500ormore
100ormore
(Unit:mm(inch))
4. Obstacles in front and behind
Theunitcanbeusedbyat-
tachinganoptionaloutdoor
blowingguide(MAC-
856SG)(butbothsidesand
topareopen).
100ormore
500ormore
Blowingguide(MAC-856SG)
(Unit:mm)
BN79A289H01_en.indd 2 2016/04/20 14:52:57
Loading ...
Loading ...
Loading ...