Operation (Automatic and Manual modes)
36
Adjusting or deactivating the filter
saturation indicator for the charcoal
filters
Charcoal filters are needed for
recirculation mode.
You can set the filter saturation
indicator to suit your cooking habits.
It has to be deactivated for extraction
mode.
It is set at the factory for 180hours of
use before it needs to be replaced.
Switch the ventilation hood off. The
canopy must be retracted.
Remove the grease filters.
The controls are accessible via the slots
for the grease filters.
Press the control and the
operating-hours control at the
same time.
The charcoal filter symbol and one of
the blower power level indicators will
flash.
The indicators 1 to B show the current
time setting:
Indicator 1 ............................. 120hours
Indicator 2 ............................. 180hours
Indicator 3 ............................. 240hours
Indicator B.......................... deactivated
Press the or control to select the
required duration.
Confirm the selection by pressing the
operating-hours control.
All the indicator lights will go out.
If the selection is not confirmed within
4minutes, the system will revert to the
previous setting.