Rinnai CCSE3302B-36 Sunmaster Close Coupled System

Operation Installation Manual - Page 24

For CCSE3302B-36. Also, The document are for others Rinnai models: SP200B, SP200BEX

PDF File Manual, 60 pages, Read Online | Download pdf file

CCSE3302B-36 photo
Loading ...
Loading ...
Loading ...
STANDARD INSTALLATION
Fastening Collectors to a Tiled Roof
WARNING
This type of installation is not suitable for use on roofs over 10 m high�
This type of installation is not suitable for use in cyclonic areas�
Fasten the collector mounting straps to the mounting rail�
Attach the collector mounting straps to the rafter or truss
under the tiles�
Nail strap to rafter
Tiles removed
Place the collector(s) onto the roof above the lower rail� If
more than one collector is being installed then join them
together using the barrel unions supplied�
Using the supplied self drilling screws, fasten the rail to
the collector, through the square holes in the rail Do
not fasten in other locations as damage to the collector
header pipe may occur� Be careful to adequately tighten
the screws to ensure the connection is secure without
stripping the threads in the collector case�
Position the upper collector rail above the collectors�
Fasten the rail to the collector, through the square holes
in the rail using the supplied self drilling screws�
Attach the collector mounting straps to the rafter or truss
under the tiles�
Nail strap
to rafter
Tiles removed
Replace the tiles and ensure the collector is secure, and
the roof is weather tight�
WARNING
Please ensure the collector rails are positioned in the correct orientation against the collector
Rinnai 24 CC B OIM
INSTALLATION - ALL SYSTEMS
Loading ...
Loading ...