Technical Characteristics and Dimensions | 7
6 720 608 992 (2011/12)
2.7 Electrical diagram
Fig. 3 Electrical diagram
1 Ignition electrode
2 Ignition unit
3 Switch/LED - Low water pressure indicator
4 Digital display
5 Ionisation probe
6 Flue gas safety device
7 Overtemperature switch
8 Temperature sensor
9 Pilot solenoid (Normally Closed)
10 Diaphragm valve
11 Main Solenoid (Normally Open)
12 Hydrogenerator
13 LED - Burner status check
2.8 Function
This gas heater is equipped with automatic electronic
ignition to simplify operation.
B To activate, just turn on the switch (Fig. 8).
After this, automatic ignition occurs whenever a hot
water tap is opened. First, the pilot burner is lit and
approximately four seconds later the main burner
ignites. The pilot burner flame is extinguished after the
main burner lights.
This is a way of saving a great amount of energy as the
pilot burner only operates for the minimum necessary
time to ignite the main burner.