Loading ...
Loading ...
Loading ...
12 | Installation
6 720 608 992 (2011/12)
4.6 Pressure Relief
The pressure relief (Fig. 2, pos. 33) will release pressure
from the system whenever the value exceeds 1500 kPa.
4.7 Gas connection
Gas regulator
The appliance is supplied with a gas pressure regulator
that must be installed on the heater before attaching the
gas supply line (see Fig. 6).
B Use sealing tape to assure the complete tightness of
the installation.
Fig. 6 Gas regulator
4.8 Testing
B Turn on the gas and water cocks and check all
connections for leaks. If all connections are sound
then follow procedures set out in Section 6 for
adjustment of Gas Pressures.
DANGER:
If local regulations are not followed, a fire or
explosion could result causing property
damage, personal injury, or loss of life.
Size gas supply as per AS5601.
Incorrect gas pipe sizing will not be covered
by the warranty.
6720608992-02.1JS