INSTALLATION
GAS HOOKUP
GAS REQUIREMENTS:
Verify the type of gas supply to be used, either natural or LP. Make sure the marked gas on the appliance rat-
ing plate(s) and hook-up kit agrees with that of the supply.
IMPORTANT!
Never connect an unregulated gas line to the appliance.
An installer supplied gas shut-off valve must be installed in an easily accessible location.
All pipe sealants must be an approved type and resistant to the actions of LP gases. Never use pipe sealant on
flare fittings.
Gas conversion kits are available from the factory. When ordering, have the model number, and the type of gas
(natural or LP) which you need.
Total gas consumption of the professional side burner with burner(s) on “HIGH”Table 1 below.
TABLE 1
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5kPa.).
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2
PSIG (3.5 kPa.).
The installation of this appliance must conform with local codes or in the absence of local codes, with the Na-
tional Fuel Gas Code, ANSI Z223.1/NFPA 54. Installation in Canada must be in accordance with the Standard
CSA B149 and/or .2 (installation code for gas burning appliances and equipment) and local codes.
All gas connections must be made by a qualified technician.
NATURAL GAS HOOKUP:
CONNECTION: 1/2” NPT male with 3/8” flare adapter.
OPERATING PRESSURE: 4.0” W.C.
SUPPLY PRESSURE: 5” to 14” W.C. If in excess of 14” W.C., a step down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be
sure to check on type and size of run, and how deep to bury the line. If the gas line is too small, the profes-
sional side burner will not function properly.
MODEL Btu/hr
BGC131 17,000
BGC132 34,000
BGC131-BI 17,000
BGC132-BI 34,000