8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
44
CLB MAINTENANCE
DAILY WEEKLY
MONTHLY
BI-YEARLY
Check pits for water level (Overfl ow/dry).
X
Check for voltage to machine
and that control panel switches are on.
X
Check all plumbing for leaks.
X
Check inlet fl ow meter for
proper fl ow. Clean meter if needed.
X
Check that inlet and discharge
manifold hoses and valves are in proper position.
X
Check ozone generator bulb.
Bright light-replace. Dim light good.
X
Clean and test pH probe if applicable*.
X
Suction pits of sludge and debris.*
X
Check and clean sump pump of dirt and debris.*
X
Clean fl oats in sump if accumulating dirt or grease. *
X
Check fl oat wires for cuts or frays.
X
Check and clean chemical injectors.
X
Check tubing on pH controller for splits or cracking.
X
Check standard cubic feet per
hour (SCFM) on ozone generator.
X
Check surge tank pressure.
X
Check transfer pump switch settings.
X
Open drain valve to purge solids.
X
Empty debris dumpster
X
Pressure wash front and back of debris dumpster.
X
Clean trench
X
Check timers for proper settings
X
Replenish BioStax 1800 and BioNutrient if applicable*
X
* Note: this is a guide. Depending on your wash load these items may have to be done more or less often.