8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
32
ATTENTION: Ne jamais regarder la lampe d'ozone
non protégée pendant l'utilisation de la machine.
Cette lampe peut causer de graves dommages
aux yeux et à la peau. Le voyant lumineux sera
vert (faible) ou éteint lorsque l'appareil fonctionne
correctement. Le voyant passe à un vert vibrant
lorsqu'une défaillance est présente. Consulter
la description du produit pour l'emplacement du
témoin lumineux.
Testing the Lamp:
(See Ozone Generator Testing Illus.)
To test the ozone lamp, use a voltmeter set on ohms.
First remove the ozone cover and unplug the lamp
plug from the ozone lamp. NOTE: There are two
laments - an upper and a lower - inside the lamp.
Place one of the voltmeter leads on one of the lamp
prongs and, with the other lead, touch all of the three
remaining prongs. If continuity is not achieved on both
upper and lower fi laments, replace the ozone lamp
(Part #6-0534).
To test the power pack, use a voltmeter set on the
correct voltage (240V). Place one of the voltmeter
leads into the lamp plug where the white wire goes
into it and plug the other voltmeter lead into the lamp
plug where the blue wire goes into it. If no voltage is
present replace the ozone ballast (Part #6-05232 -
240V). When ordering an ozone ballast, you also need
the 4-pin connector (Part #6-05233).
Replacing the lamp: (See Ozone Generator Break-
down)
89144580-39
Ozone
Lamp
Prongs
Ballast
OZONE GENERATOR TESTING
Four Pin
Connector
OZONE GENERATOR
Ozone...Nature’s Purifi cation Agent:
Ozone is produced in nature or artifi cially by man. In
the earth’s atmosphere, ozone is formed when oxygen
is exposed to ultraviolet light or an electrical charge
as during thunderstorms. Ozone’s primary function in
nature is to purify the air we breathe and screen us
from harmful rays of the sun. In a similar fashion, the
CLB system uses ozone to disinfect water because
Ozone has a number of characteristics that make it
ideal for water treatment.
Ozone’s Characteristics:
Ozone is well suited for water treatment, and it’s unique
characteristics are described below:
Ozone works up to 3,000 times faster than
chlorine to kill bacteria and destroy harmful
microorganisms.
Ozone is a more powerful oxidizing agent than
chlorine and bromine, having a better ability to
remove water contamination.
Ozone will not form harmful by-products, like
THM’s (a problem in drinking water), or chlo-
ramines, (by-products of chlorine that are re-
sponsible for odors, skin irritations and burning
eyes.)
Ozone will not alter the water’s pH, reducing pH
uctuations.
Ozone coagulates small particles in water so
clarity is dramatically improved.
Ozone acts as a deodorizer removing unpleas-
ant odors from water.
How the CLB Ozone System Works:
Because ozone is unstable, it cannot be packaged and
used at a later date. For this reason, ozone is always
produced where it is utilized.
Point-of-use ozone generation is simple. This powerful
disinfectant is produced from ambient air surrounding
the generator using special ultraviolet lamps located
inside the system’s cabinet. To generate the ozone,
air movement is created through the use of an air
compressor or water venturi. As air passes over
these unique lamps, the oxygen contained in the air
is converted. The resulting ozone gas is subsequently
introduced to the water in the inlet pipeline, where
oxidation and disinfection immediately take place.
Ozone Generator Maintenance:
CAUTION: Never look at the unshielded ozone
lamp while operating the machine. This lamp can
cause severe eye and skin damage. The indica-
tor light will be a dim green or not lit at all when
operating properly. The light glows a bright green
when there is a failure. See product description
for location of the indicator light.