OPERATOR’S MANUAL
For the dealer nearest you, consult our web page at www.wmaze.com
CLB-603
TREAT AND RECYCLE
WARNING:
This product and accessories may contain a chemical known to the State
of California to cause cancer and birth defects or other reproductive harm.
For more information about this regulation: www.P65Warnings.ca.gov
ADD ONS: CLB-30 CLT-300 CLT-600
89144580-8
8.914-458.0-G05/22/18
background
CONTENTS
2
8.914-458.0-G • Water Maze CLB-603
Introduction and Important Safety Issues ............................................4-5
How the Bio-System Works .................................................................6, 7
Consumables ..........................................................................................7
Operating Environment ...........................................................................7
Operating Tips .........................................................................................7
Bio-System Component Identifi cation ..................................................8-9
Installation Instructions ......................................................................9-11
Start-up .................................................................................................12
CLB-603 Installation View with Optional CLT-300 .................................13
CLB-603 Installation View .....................................................................14
CLB-603 Electrical Installation View......................................................15
CLB-603 Water Panel Installation .........................................................16
CLB Control Panel ................................................................................17
Piping Connection Diagram #1 and Table ........................................18-19
Piping Connection Diagram #2 and Table ........................................20-21
Piping Connection Diagram #3 and Table ........................................22-23
Electrical Field Connection CLB-603A Diagram and Table ..............24-25
Air Connection Diagram ........................................................................26
Recycle Holding Tank Installation ..........................................................27
Metering Pump Operation .....................................................................28
Metering Pump Maintenance ................................................................ 29
Metering Pump Exploded View and Parts List ......................................30
Pressure Switch and Pressure Tank Operation .....................................31
Ozone Generator .............................................................................32-34
Optional pH Digital Controller Model 240 ..............................................36
Troubleshooting - pH Sensor .................................................................37
Troubleshooting - Infeed, Ozone and Transfer Pump ............................38
Troubleshooting - Pump ........................................................................39
Troubleshooting - Pump Motor ..............................................................40
Troubleshooting - Water Solenoid .........................................................41
background
3
CONTENTS
Part Number ______________________________
Serial Number ______________________________
Date of Purchase ___________________________
The part and serial numbers will be found on a decal attached to
the machine. You should record both serial number and date of
purchase and keep in a safe place for future reference.
8.914-458.0-G • Water Maze CLB-603
Troubleshooting - Water Seals ..............................................................42
CLB Maintenance.............................................................................43-44
CLB-603 Component Assembly Exploded View & Parts List ...........45-46
CLB-603 Air Stone Assembly Exploded View and Parts List ...........47-48
CLB-603 Infeed Pump Assembly Exploded View & Parts List .........49-50
CLB-603 Transfer/Ozone Pump Assembly Exploded View
& Parts List .......................................................................................51-52
CLB-603 Drain Surge Tank Exploded View & Parts List ..................53-54
CLB-603 Air Components Exploded View & Parts List ....................55-56
CLB-603 Manifold Assembly Exploded View & Parts List ................57-58
Water Panel Exploded View & Parts List ..........................................59-60
CLB-603 Control Panel Exploded View & Parts List ........................61-62
CLB-603 Dimension Locations of Tank Connections ............................63
Ozone Generator Exploded View & Parts List ......................................64
CLB-30 Auxiliary Digester Assembly Exploded View & Parts List ...65-68
CLT-300 Tank Assembly Installation Exploded View & Parts List .....69-70
CLT-300 Tank Assy Options Exploded View & Parts List..................71-72
CLT-600 Tank Assembly Exploded View & Parts List .......................73-74
Oil Skimmer Assembly Exploded View and Parts List .....................75-76
Ozone Filter Pump Exploded View & Parts List ....................................77
Optional Transfer Pump Exploded View & Parts List .............................78
Transfer Pump Exploded View & Parts List ...........................................79
Infeed Pump Exploded View & Parts List ..............................................80
Warranty
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
4
Your owner’s manual has been prepared to provide
you with a simple and understandable guide, for equip-
ment operation and maintenance, based on the latest
product information available at the time of printing. To
keep your machine in top running condition follow the
specifi c maintenance and troubleshooting procedures
given in this manual. When ordering parts please
specify model and serial number.
NOTE: WATER MAZE reserves the right to make
changes at anytime without incurring any obligations.
Owner/User Responsibility:
The owner and/or user must have an understand-
ing of the manufacturer’s operating instructions and
warnings before using this pressure washer. Warning
information should be emphasized and understood.
If the operator is not fl uent in English, the manufac-
turer’s instructions and warnings shall be read to and
discussed with the operator in the operator’s native
language by the purchaser/owner, making sure that
the operator comprehends its contents.
Owner and/or user must study and maintain for future
reference the manufacturers’ instructions.
SAVE THESE INSTRUCTIONS
This manual should be considered a permanent
part of the machine and should remain with it if
machine is resold.
When ordering parts, please specify model and
serial number. Use only identical replacement
parts. This machine is to be used only by trained
operators.
WARNING: When using this ma-
chine basic precautions should
always be followed, including
the following:
CAUTION: To reduce the risk of
injury, read operating instruc-
tions carefully before using.
1. Read the owner's manual thor-
oughly. Failure to follow instruc-
tions could cause malfunction of the machine and
result in death, serious bodily injury and/or property
damage.
2. Know how to stop this product and bleed pressures
quickly. Be thoroughly familiar with the controls.
3. Stay alert - watch what you are doing.
WARNING: Ground system be-
fore connecting to the power
supply.
AVERTISSEMENT: Mettre le
système à la masse avant
de le raccorder à la source
d'alimentation.
WARNING: Wire the system for correct voltage.
See “Electrical” section of this manual and motor
nameplate.
AVERTISSEMENT: Raccorder le système au ré-
seau électrique en respectant la tension. Consulter
la section « Électricité » du présent manuel et la
plaque signalétique du moteur.
WARNING: Meet the National
Electrical Code and local codes
for all wiring.
AVERTISSEMENT: Respecter le
Code national de l'électricité et
les codes locaux pour tous les
câblages.
WARNING: Follow the wiring
instructions in this manual
when connecting the system
to the power lines.
AVERTISSEMENT: Suivre les instructions de
câblage dans le présent manuel au moment de
raccorder le système aux lignes de transport
d'électricité.
WARNING: All wiring must be performed by a
qualifi ed electrician.
AVERTISSEMENT: Tout le câblage doit être effec-
tué par un électricien qualifi é.
4. Know the system application, limitations, and
potential hazards.
WARNING: Do not use to pump
concentrations of flammable
or explosive fl uids such as gasoline, fuel oil, kero-
sene, etc. Do not use in explosive atmospheres.
Pumps should only be used with liquids compat-
ible with pump component materials. Failure to
follow this warning can result in personal injury
and/or property damage.
AVERTISSEMENT: Les pompes devraient être utili-
sées uniquement avec des liquides compatibles
avec les matériaux des composants des pompes.
Le non-respect des précautions peut mener à
des lésions corporelles et/ou des dommages à la
propriété.
5. WARNING: Risk of electric shock.
AVERTISSEMENT: Risque de choc électrique
All wiring should be performed by a qualifi ed
electrician.
6. Never make adjustments on the machine while it
is in operation, except for those prescribed in this
manual.
WARNING
KEEP WATER SPRAY
AWAY FROM
ELECTRICAL WIRING.
WARNING
READ OPERATOR’S
MANUAL THOROUGHLY
PRIOR TO USE.
INTRODUCTION & IMPORTANT SAFETY INSTRUCTIONS
WARNING
RISK OF EXPLOSION:
DO NOT SPRAY
FLAMMABLE LIQUIDS.
background
8.914-458.0-G • Water Maze CLB-603
5
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
7. The main power must be brought from the circuit
breaker and wired into the electrical box on the
CLB. This line must be run through conduit to pro-
tect it from damage. A power disconnect should
be located next to the machine for maintenance
purposes.
8. Before servicing the machine, refer to all the MS-
DS’s on the material identifi ed in the wastestream.
You must comply with all warnings and wear all
protective clothing as stated on the MSDS’s.
9. Protect all electrical cords from sharp objects,
hot surfaces, oil, sunlight, and chemicals. Avoid
kinking the cords. Replace or repair damaged or
worn cords immediately. All wiring should be run
through conduit.
10. Inlet water temperature must not exceed 85°F.
11. Disconnect the power before servicing this
machine. If the power disconnect is out of sight,
lock it in the open position and tag it to prevent
unexpected application of power.
12. The best insurance against an accident is
precaution and knowledge of the equipment.
13. WATER MAZE is not liable for modifications
or use of components not purchased from
WATER MAZE.
14. Personal Safety:
a. Wear safety glasses and other applicable
protective clothing at all times when working
on this machine.
Refer to item #6 under Important Safety
Information.
b. Keep your work area clean, uncluttered and
properly lighted. Replace all unused tools and
equipment.
c. Keep visitors at a safe distance from work
area.
d. Make the workshop safe with padlocks and
master switches.
15. Running the system without water will damage the
pumps and will void the warranty.
16. Release all pressure within the system before
servicing any component.
17. Drain all liquids from the component before
servicing.
18. Check hoses for weak or worn conditions before
each use, making certain that all connections are
secure.
19. Periodically inspect pump and system compo-
nents. Perform routine maintenance as required.
20. Do not touch an operating motor. Modern motors
are designed to operate at high temperatures.
IMPORTANT SAFETY INSTRUCTIONS
21. Do not handle a pump or pump motor with wet
hands, when standing on a wet or damp surface,
or in water.
22. The pump motors are equipped with an auto-
matic resetting thermal protector and may restart
unexpectedly. Tripping is an indication of motor
overloading as a result of operating the pumps at
low heads (low discharge restriction), excessively
high or low voltage, inadequate wiring, incorrect
motor connections, or a defective motor or pump.
23. IMPORTANT NOTE: The sump pump is not a
trash pump and is subject to premature failure
unless sump pit baffl ing or additional protection
is provided.
24. Keep machine from freezing.
25. Do not spray water directly at machine.
WARNING: The Bio-System contains moving parts
in the control center and in the pumps. Follow
safe practices when performing maintenance and
when troubleshooting the Bio-System. Set circuit
breakers to the off position when working on elec-
trical equipment. Use proper lockout and tag out
procedures when setting the breakers.
AVERTISSEMENT: Le Bio-System contient des
pièces mobiles dans le centre de contrôle et dans
les pompes. Suivre les pratiques de sécurité au
moment d'effectuer des opérations d'entretien et
lors de la correction des erreurs. Régler les dis-
joncteurs en position d'arrêt au moment d'effectuer
des opérations d'entretien sur l'équipement élec-
trique. Utiliser des procédures de verrouillage et
d'étiquetage appropriées au moment d'enclencher
les disjoncteurs.
WARNING: If any cords or electrical wires appear to
be frayed, damaged, or in poor condition, proceed
with caution and immediately take steps to have
the cords repaired or replaced.
AVERTISSEMENT: Si un cordon ou des fi ls élec-
triques semblent effi lochés, endommagés ou en
mauvais état, agir avec prudence et prendre im-
médiatement des mesures afi n que les cordons
soient réparés ou remplacés.
WARNING: Make sure to take precautions when
performing maintenance on the pump in the catch
basin. Turn off the power to the pump and make
sure electrical cords are well maintained.
AVERTISSEMENT: S'assurer de prendre les pré-
cautions nécessaires au moment d'effectuer des
opérations d'entretien sur la pompe. Mettre la
pompe hors tension et s'assurer que les cordons
électriques sont bien entretenus. dans le bassin
collecteur.
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
6
HOW THE BIO-SYSTEM
WORKS
The Bio-System is an industrial grade microbial treat-
ment system, with modular components, that employs
naturally occurring microbes to treat waste water with
characteristics that include organic compounds (i.e.,
emulsifi ed oils and hydrocarbons). A typical application
may include treatment of wash water generated from
equipment washing (i.e., washing golf course main-
tenance equipment, fork lift repair, truck wash etc.).
As compared to other water treatment technologies,
microbial treatment is highly dependent on maintaining
a healthy environment for the microbes that perform
the job of digesting organic substances and converting
them to carbon dioxide and water. Some of these life
sustaining considerations are:
pH of the water (should be between 6.0 and 9.0)
• water temperature (should be above 40°F and
below 120°F)
adequate nutrient & food supply within the water
(consult with Water Maze) and
adequate levels of dissolved oxygen (enough
dissolved oxygen to overcome the consumption
rate /oxygen demand).
In addition to the above considerations, the effl uent
water quality from a Bio-System will be subject to
the concentration levels of the organic matter in the
untreated water and the relative dwell time required
for microbial digestion. Based on these factors, waste
waters with consistent concentration levels of organic
matter will be more predictable in terms of effl uent
water quality. Conversely, waste waters with fl uctuat-
ing concentration levels of organic matter may vary in
terms of effl uent water quality.
IMPORTANT NOTE: Subject to the application and
desired water quality requirements, processed water
from a Bio-System may require additional post-treat-
ment.
IMPORTANT NOTE: Recycled water quality is depen-
dent upon many factors, including, but limited to the
above considerations and should be tested to assure
that the water quality meets the intended reuse.
IMPORTANT NOTE: Local regulations may limit what
you can do with water that is discharged from the
Bio-System or may require specifi c permits. Check with
local authorities if you are unsure about the uses or
disposition of the water discharged by the Bio-System.
Regulations may also limit the use of a wash pad as
a mix and load station.
WARNING: The Bio-System is not designed to
produce potable water. Do not use water from
Bio-System for drinking or washing humans or
animals.
AVERTISSEMENT: Le Bio-System n'est pas conçu
pour produire de l'eau potable.
A typical Bio-System may be confi gured as a Treat &
Discharge System, or as a Treat & Recycle System. In
either case, a properly confi gured system may consist
of one or more components (See Bio-System Compo-
nent Identifi cation pages). As in all properly designed
water treatment systems, Water Maze highly recom-
mends that appropriate pretreatment technologies be
applied to the waste water for the purpose of enhanc-
ing the performance of the Bio-System. Some typical
pretreatment technologies may include: oil -skimming
to remove "free-oils", heavy solids removal; pH control;
water temperature control; grass clipping removal;
inorganic material removal (i.e., heavy metals); etc.
A few pretreatment technologies are contained within
this operator's manual (i.e. CLT-300; Hydro-Screen,
Debris Dumpster, etc.). For additional pretreatment
recommendations for your application, please consult
an authorized Water Maze representative.
The CLB-603 model (for recycle applications) typically
works as follows:
The CLB-603 is the primary digester that houses
the microbial colony and is the primary control
center for the system.
The in-feed transfer pump (mounted on the
CLB-603 platform) draws pretreated water from
the pit system or from a pretreatment feed tank
(i.e., CLT-300 tank), and fi lls the 600-gallon di-
gester tank. A control fl oat is supplied with the
CLB-603 unit. NOTE: See in-feed pump curve for
maximum lift capacity.
The in-feed pump also acts to circulate water
during the off-hours. A pin-type timer allows the
operator to control the frequency and duration for
circulation.
Water being circulated will be sourced from inside
the top portion of the CLB-603, or from the last
above ground tank connected to the CLB-603
digester (e.g., this could be the last of multiple
CLT-600 tanks plumbed in series).
During the timed circulation, an air-actuated direc-
tional control valve blocks new (untreated) waste
water from entering the CLB-603 digester.
If the application requires pH adjustment, an
optional pH control may be employed as the un-
treated water is transferred into the CLB-603.
On a routine basis (once each day) microbes and
nutrients (if required) are automatically injected
into the CLB-603 tank. This is done to assure that
HOW THE BIO-SYSTEM WORKS
background
8.914-458.0-G • Water Maze CLB-603
7
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
the microbe population (colonized within the bio-
lm contained inside the CLB tank) is maintained
at maximum levels.
Dissolved oxygen is maintained using a unique
delivery system.
The CLB-603 incorporates a propriety 600-gallon
cone-bottom tank with a 55 degree slope that al-
lows for easy solids removal using an air-actuated
timer-controlled purge valve.
Subject to the application requirements, additional
above-ground holding tanks (CLT-600), or auxiliary
digesters (CLB-30) may be coupled in series to
the CLB-603 digester.
Processed water gravity fl ows into a holding tank
(not supplied as part of a CLB-603), which should
be sized based on application requirements.
The processed water holding tank will house con-
trol fl oats that control fresh water make-up, excess
water discharge, the recycled water transfer pump,
and the ozone circulation pump.
For polishing the water for recycle purposes, the
CLB-603 includes a 4-tube UV ozone generator
with injector, circulation pump and timer.
Upon demand of the operator or via the excess
water fl oat control, water contained inside the
process water holding tank is delivered through a
pressurized manifold system.
As water returns into the pretreatment system, the
process of treatment begins again.
CONSUMABLES
Microbes and Nutrients
BioStax 1800: Liquid Bacteria Concentrate
Part # 8.718-919.0 BioStax, 1800, 8 oz. vials, 2 part
mix, part A and B. It is an environmentally friendly, non-
toxic and non-pathogenic liquid concentrate. Controls
odor, reduces oils and greases, other hydrocarbons,
animal fats and vegetable oils. Two 8 oz. bottles pack
A & B makes 5 gals.
BioStax 100: Hawaiian Blend Liquid Bacteria
Concentrate
Part # 8.718-917.0 comes in an 8 oz. bottle and works
the same as BioStax 1800 except that it is for use in
Hawaii. One 8 oz. bottle makes 5 gallons.
Bio Nutrient: Powder Bacteria Nutrient Source
Part # 8.718-916.0 comes in an 8 oz bottle and easily
mixes in water to make 5 gallons. It is introduced into
the Bio-System along with the bacteria to enhance the
growth and effectiveness of the biology.
The Bio-System is designed to work in a wide variety
of operating conditions. In normal operating environ-
ments, the Bio-System should perform as specifi ed. In
extremely hot or cold environments certain precautions
need to be taken.
Operating Conditions
Air Temperature Range 40° - 120°F
Treatable Waste Water contaminated
with hydrocarbons and
organic material
Water pH 6.0 - 9.0
Cold Weather
Protect the Bio-System from damage that can occur
when freezing water expands. Freezing water may
cause pipes leading from the catch basin to your
Bio-System tanks to burst. Plus, the microbes in the
BioStax 1800 may not survive if they are frozen.
Drain all external pipes if a prolonged hard freeze is
expected. Make sure all valves (including the valve
controlling the fl ow of water to the hose connected to
the hydro-screen) are open so water can completely
drain from the system. Disconnect the pump in the
catch basin (sump) using the camlock and drain the
pump and pipes. The pump may be left in or near the
sump and doesn’t need to be disconnected from the
electrical system. In extreme weather conditions also
drain the Bio-System, using the drain valves at the
bottom of each tank.
In order to restart your Bio-System, you will need to
reinoculate your system with BioStax 1800 at start-up.
The recommended amount of BioStax 1800 for start-
up is fi ve 8 oz. bottle sets, part A & B, for a Bio-System
system. Contact WATER MAZE for specifi c instructions
to restart your Bio-System.
Hot Weather
Your Bio-System may encounter minor problems,
such as a slight increase in odor, when operating in
extremely hot temperatures in excess of 100° F. If
odor is a problem, add water to the system on a daily
basis by running tap water into the catch basin (sump).
The sump pump will automatically add the water to
the system.
OPERATING TIPS
Your Bio-System is extremely simple to operate. Sim-
ply wash your equipment or vehicles as you would
normally.
In extremely dirty environments, you may want to
“pre-clean” your equipment with air or with a brush,
removing grass directly to debris dumpster.
Use hose end sprayers with automatic shutoffs
when washing equipment so as to not exceed the
peak capacity of your Bio-System.
Perform the daily, weekly and monthly service as
described on the maintenance pages.
OPERATING ENVIRONMENT
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
8
BIO-SYSTEM COMPONENT IDENTIFICATION
CLB-603
Recycle: Main Bio-Digester
Fully automated bio-remediation system includes:
Microbe and nutrient injection system
Infeed pump with circulation system
Ozone generator with circulation pump
Aerator provides dissolved oxygen to water for
microbe health
Auto purge drain system
Optional pH control system
600 gallon unit volume
CLB-30D
Auxiliary Bio-Digester
Auxiliary modular unit con-
nects to main bio-digester (either
CLB-603 or 600) or it can be added to
another tank or system. The CLB-30D,
when added to a main bio-digester, al-
lows you to increase the total fl ow rate
as needed. Unit volume is 600 gallons
with process capacity site specifi c.
CLT-600
Auxiliary Tank: 600 Gallons
600 gallon cone-bottom tank is used
as a pre-treatment or post-treatment
tank, as needed. Biology is not inject-
ed into this tank, but it provides added
dwell time for biological processing.
CLT-300
Auxiliary Tank: 300 Gallons
300 gallon cone-bottom tank is used
as a pre-treatment or post-treatment
tank, as needed. Has sockets for a
mounting bracket to hold the optional
hydro-screen, when needed.
NOTE: The Water Maze Bio-System is modular
so components can be combined in a variety of
combinations. Your system may not include all of
the components shown below or on next page.
89144580-21
89144580-6
89144580-6
89144580-41
background
8.914-458.0-G • Water Maze CLB-603
9
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
BIO-SYSTEM COMPONENT IDENTIFICATION
Debris Dumpster
Utilized to de-water solids (especially in golf course
installations as containment for grass clippings cas-
cading from Hydro-Screen).
Ozone Generator
The ozone generator produces ozone generated by
special UV lamps, to disinfect water.
89144580-24
OZONE GENERATOR
DISCONNECT FROM ELECTRICAL
SUPPLY BEFORE SER
VICING.
DESCONECTE LA CORRIENTE ELECTRICA
ANTES DE
D
AR SE
R
VICI
O
.
COUPER
L
’ALIMENTA
TION ÉLECTRI
Q
UE
AV
ANT DE F
AIRE UNE RÉ
PAR
ATION .
DISCONNECT FROM ELECTRICAL
SUPPLY BEFORE SER
VICING.
DESCONECTE LA CORRIENTE ELECTRICA
ANTES DE DAR SERVICI
O
.
COUPER L’ALIMENTATION ÉLECTRI
Q
UE
AV
ANT DE FAIRE UNE RÉPARATION.
INDICATOR
L
IGHT OPERATION
A b
r
ight conti
nuous light indica
tes UV
light or ballast de
f
ecti
v
e
.
Una luz luminosa indica que la luz ult
r
a-
vi
oleta o t
ransf
o
r
mador está d
efectuoso
.
Une lumière claire indique que la lumière
ultraviolette ou le transf
o
rmateur est
f
ectueux.
OPERACION DE LA LUZ
INDICADORA
OPÉRATION DE LE LAMPE
INDIC
ATEU R
HOT!
C
ALIENTE!
C
HAUD!
CAUTION
PRECAUCION
ATTENTION
8.900-455.0
!
WARNING!
ATENCION!/
A
TT
ENTION
!
!
Hydro-Screen
For Screening Leaves, Grass
24" Hydro-Screen effectively screens leaves, grass
clippings and other bio-mass prior to reaching
bio-digester. Includes removable screen for easy
cleaning.
Hydro-Screen Stand
Free standing support for Hydro-Screen. Must be
bolted to washpad using concrete anchors.
89144580-27
89144580-28
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
10
INSTALLATION
INSTRUCTIONS
The following instructions will provide adequate infor-
mation to fully install your Water Maze Bio-System.
Please follow these instructions step by step to ensure
proper installation.
Equipment Need for Installation
Aside from having a general assembly of tools on
hand, you will need to supply a few additional items
to complete the installation of your system:
Gray PVC medium set glue
Purple primer
Tefl on tape
Lubricant (liquid soap)
Pipe fi ttings
Pipe
Installation Instructions
1. Placing the Bio-System
Place the Bio-System on a level concrete pad
similar to what is shown on the Installation Views
and the Installation and Piping Diagrams.
NOTE: Your system may not require all of the
components shown.
2. Placing and Connecting Hydro-screen
(if applicable)
a. Mount hydro-screen on tank or stand as shown
in Installation Drawing.
b. Line up the chute from the hydro-screen so it is
above the sloped end of the debris dumpster.
c. Connect the 1-1/2" hose between hydro-screen
and sump pump connection.
NOTE: The hose may have to be cut to size be-
fore it is connected. The hose should reach both
connections and make a smooth arch without an
excess of slack in the line.
3. Place the Debris Dumpster
a. Review Installation Drawing.
b. Place the debris dumpster under the hydro-
screen so that debris falls onto slope section
of dumpster (see 2b).
4. Placing the Sump Pump (if applicable)
Review Installation Drawing.
a. Connect PVC tee with gate valve to the 1-1/2"
pipe stubbed out of the sump pump. The elbow
of the gate valve should be facing down toward
the bottom of the catch basin.
b. Place pump securely into corner of catch
basin.
c. Connect plumbing of the sump pump to un-
derground piping supplied by customer. See
Piping Connection Diagrams.
5. Plumbing the System
Connect equipment with plumbing as shown on
the Installation and Piping diagrams. NOTE: your
system may not require all of the components
shown. Plumbing may vary depending on place-
ment of equipment.
6. Wiring the System
Electrical power is OFF. Before beginning work
refer to Safety Instructions in front portion of man-
ual. Confi rm that there is not an electrical power
source connected to the control panel. Electrical
power will be connected to control panel later in
these instructions.
a. Connect wiring as shown on Electrical Con-
nection Diagram. NOTE: your system may not
have all the components shown.
7. Connecting Air Supply to the System
a. Connect equipment with air lines as shown on
the Air Connection Diagram.
b. Connect air source to pressure regulators. Air
source must supply 4 CFM at 60-100 psi.
8. Filling the Tanks Dosing the Bio-System
NOTE: Your system may not have all of the com-
ponents listed below.
a. CLB-603 (or CLB-600): Fill tank until water
begins to fl ow from 3" overfl ow pipe. Add one
8 oz. bottle set part A & B of BioStax 1800 and
one 8 oz. bottle of BioNutrient.
b. CLT-300: Add enough water to fi ll lower cone
section. No BioStax 1800 or BioNutrient re-
quired.
c. CLB-30: Fill tank until water begins to fl ow from
3" overfl ow pipe. Add one 8 oz. bottle set part
A & B of BioStax 1800 and one 8 oz. bottle of
BioNutrient.
d. CLT-600: Fill tank until water begins to fl ow from
3" overfl ow pipe. Add one 8 oz. bottle set part
A & B of BioStax 1800 and one 8 oz. bottle of
BioNutrient.
e. Recycle Holding Tank: Fill tank approxi-
mately half full. No BioStax 1800 or BioNutrient
required.
f. Sump Pit: Pour one 8 oz. bottle set part A
& B of BioStax 1800 and one 8 oz. bottle of
BioNutrient into sump pit.
9. Microbe and Nutrient Injection
INSTALLATION INSTRUCTIONS
background
8.914-458.0-G • Water Maze CLB-603
11
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
set to inject during system non-use hours.
Pulling a pin on this timer will cause the Microbe
and Nutrient pump to operate automatically
when their hand switches are on.
11. Water Panel Connections:
a. Connect a garden hose from the city water sup-
ply to the "Fresh Water Inlet" connection on the
water panel. Refer to Water Panel Installation
Drawing. Make sure hand valve V5 is open.
b. Connect a garden hose from "Outlet to Pres-
sure Washer" on water panel to your pressure
washer. Make sure hand valve V7 is open.
Installation Checklist
Is all piping connected as shown on the Instal-
lation and Piping Diagrams?
Is electrical wiring connected as shown on the
Electrical Connection Diagram?
Are air lines connected as shown on the Air
Connection Diagram?
Is the voltage correct?
Is the fresh water make-up hose connected?
Is the outlet to pressure washer hose con-
nected?
Is the rainwater overfl ow connected?
a. Mix microbes and nutrient in separate fi ve gal-
lon containers supplied.
b. Install tubing to pumps and connect to injection
probes located on side of CLB-603 tank. Refer
to attached information for installation and con-
nections.
10. Set Timers
There are four timers in your control panel enclo-
sure that need to be set. Open control panel door
to set timers. Timers are 24 hour and each pin
represents half an hour. NOTE: Always remove
electrical power from control panel prior to open-
ing the door. Rotate each timer until the hour at
the center of the dial meets the actual time of day
(a.m. or p.m.). After each timer is set for the time
of day, proceed to instructions below to set timers
to actuate equipment.
a. Infeed Pump Timer: Pull 1 Pin Separated
by 2 Pins (repeat 4 times)
The infeed pump timer provides for water cir-
culation during system non-use hours to aid in
circulation of dissolved air and biodigestion by
microbes. Circulation of water must be paused
for tank dwell time. Pulling one pin separated
by two pins (and repeated 4 times) will allow
for 30 minutes of water circulation separated
by one hour of dwell time. Pulling a pin on this
timer will cause the infeed pump to operate
automatically when the hand switch is on. The
circulation pump should be set to operate
during system non-use hours.
b. Ozone Timer: Pull 4 Pins.
The ozone timer controls the amount of time
that the ozone pump and ozone generator op-
erate. Pulling a pin on this timer will cause the
ozone pump and ozone generator to operate
automatically when their hand switches are
on. Ozone water is circulated to the recycle
holding tank to provide disinfected water. The
ozone timer should be set to operate during
system non-use hours.
c. Purge Timer: Pull 1 Pin
The purge timer controls the amount of time
that the tank purge valve operates. The purge
valve provides for sludge removal from the
bottom of the cone tank. Pulling a pin will al-
low for automatic energizing of the ten second
timer which causes the purge drain valve to
open. Set timer to coordinate with daily
maintenance schedule.
d. Microbe / Nutrient Timer: Pull 3 Pins
This timer determines the amount of microbes
and nutrients that are added to the CLB-603
tank. The microbe / nutrient timer should be
INSTALLATION INSTRUCTIONS
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
12
START-UP
1. Make sure that all equipment is level.
2. Turn on the fresh water inlet hose.
3. Fill the sump pit with water and check that the
water level does not drop. This would indicate that
the sump pump is not sealed.
4. Connect Electrical Power to Control Panel: When
connecting to the power supply, follow all electri-
cal and safety codes as well as the most recent
National Electric Code (NEC) and Occupational
Safety and Health Act (OSHA). Ground system
before connecting to the power supply. WARNING:
All wiring must be performed by a qualifi ed
electrician.
5. Control Panel Switches:
There are five hand switches located on the
front of the control panel. Turn on all fi ve switches.
Turning on these switches will allow the entire
system to operate in an automatic mode. Normally
switches are left on. The following is the functional
description of these switches.
a. Sump Pump — Hand Switch 1 (HS-1)
The sump pump supplied with this equipment
comes equipped with a level switch for high
and low sump water level control. Turning on
this hand switch will allow the sump pump to
operate in an automatic mode. Turning off the
HS-1 switch will not allow this pump to operate.
b. Infeed Pump — Hand Switch 2 (HS-2)
The infeed pump provides two functions:
1. It removes water from a pretreatment tank,
a sump or a CLT-300 and is controlled au-
tomatically by Float Switch 1 (FS-1). In the
"ON" position the infeed pump will turn on
at a high level and off at a low level. Turn-
ing off this switch will not allow this pump
to operate.
2. It provides circulation in the CLB-603 tank
to aid in bio-digestion by microbes. Circula-
tion fl ow is done on timer control. Turning
off HS-2 will not allow this pump to provide
circulation fl ow to the digester tank.
c. Transfer Pump — Hand Switch 3 (HS-3)
The transfer pump removes water from recycle
holding tank and provides for water fl ow to the
water panel. In the "on" position this pump
will operate automatically on pressure control.
Opening the Rinse Water Outlet and Outlet to
Pressure Washer valves that are located on the
water panel will cause this pump to start. Clos-
ing these valves will stop this pump. This pump
will not operate if the HS-3 switch is turned off.
d. Ozone Pump Hand Switch 4 (HS-4)
The ozone pump removes water from the
recycle holding tank, disinfects it and then cir-
culates water back into the holding tank. This
pump along with the ozone generator operates
automatically on timer control. The ozone
generator has a separate on/off switch and
this switch must be in the "on" position for the
ozone generator to operate. Neither the ozone
pump nor the ozone generator will operate if
the HS-4 is turned off.
e. Nutrient Pump
Turn "ON" the nutrient pump switch that is lo-
cated on the pump housing. The nutrient pump
is on timer control and will not operate if switch
is in the "off" position. Feed adjustment must
be at lowest setting. Refer to Metering Pump
Operation.
g. Microbe Pump
Turn "On" the microbe pump switch that is lo-
cated on the pump housing. The microbe pump
is on timer control and will not operate if switch
is in the "off" position. Feed adjustment must
be at lowest setting. Refer to Metering Pump
Operation.
6. Ozone Generator
Turn on the power switch located on the ozone
generator. The indicator lights on the Ozone Gen-
erator will have dim green lights or no lights if the
machine is working and bright green lights if the
ozone generator has malfunctioned.
Setting the Ozone Generator:
An SCFH (Standard Cubic Feet per Hour) gauge
is used to accurately measure the amount of air
owing through the ozone delivery line. In other
words, the amount of ozone being injected into the
water.
1. With the pump running, disconnect the tubing
from the ozone check valve and connect the
tubing to the bottom fi tting on the gauge. This
tube is from the ozone generator.
2. While holding the gauge vertically, connect the
tubing from the ozone injector to the top of the
gauge and read the amount indicated on the
gauge. NOTE: You are measuring suction so
make sure the tubing is attached properly.
3. Begin adjusting the metering valve until 40
SCFH is achieved.
4. Reconnect the tubing to the ozone check valve.
7. Look over the entire machine for leaks. The
machine was hydrostatically tested at the factory
but may have been damaged in shipment.
START-UP
background
8.914-458.0-G • Water Maze CLB-603
13
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-31
CLB-603 INSTALLATION VIEW WITH OPTIONAL CLT-300
Hydro-Screen
Debris
Dumpster
CLT-300
CLB-603
Sump Pump
Recycle
Holding
Tank
Return Line
Back to
Catch Basin
Trench
Inlet Line
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
14
CLB-603 INSTALLATION VIEW
89144580-32
Recycle
Holding
Tank
CLB-603
Foot Valve
Trench
Install Pipe
"T" for
Priming
Infeed Pump
background
8.914-458.0-G • Water Maze CLB-603
15
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
CLB ELECTRICAL INSTALLATION VIEW
89144580-36
Junction Box 1
Junction Box 2
Junction Box 3
Junction Box 4
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
16
89144580-19
CLB-603 WATER PANEL INSTALLATION VIEW
From Fresh
Water Supply
To Pressure
Washer
To Sewer or
Storage
V5
V8
V6
V7
To Hose Bib
background
8.914-458.0-G • Water Maze CLB-603
17
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
CLB-603 CONTROL PANEL
SUMP PUMP
BOMBA DE CAPTACION
POMPE DE PUISARD
INFEED PUMP
BOMBA DE ALIMENTACION
POMPE A L’AVANCE
BioSystem
OZONE PUMP
BOMBA DE OZONO
POMPE D’OZONE
1
ON
PRENDER
1
ON
PRENDER
1
ON
PRENDER
1
ON
PRENDER
0
OFF
APAGAR
0
OFF
APAGAR
0
OFF
APAGAR
0
OFF
APAGAR
CLB - 603
TRANSFER PUMP
BOMBA DE TRANSFERENCIA
POMPE DE TRANSFERT
RUNNING HOURS
HORAS DE OPERACION
HEURES D’OPÉRATION
PURGE
PURGAR
PURGER
VOLTAGE
VOLTAJE
OPERATING IN STRUC TIONS
INSTRUCCIONES DE OPERACION
INSTRUCTIONS D’OPÉRATION
BEFORE STARTING: Inspect all water and electrical
lines for proper connections. Read operator’s manual for
proper maintenance procedures and safety in struc tions.
START UP: Turn all pump switches on. Pumps will
automatically start when water reaches proper level.
ANTES DE PARTIR: Revise todas las lineas de agua
y electricas para asegurar su correcta conexión. Lea el
manual de operación para observar las instrucciones de
mantenimiento y seguridad.
PARA PARTIR: Ponga todos los interruptores de las
bombas a la posición ON. Las bombas partirán automáti-
camente cuando el agua alcance el nivel adecuado.
AVANT LA MISE EN MARCHE: Véri er toutes les
conduites d’eau et d’électricité pour vous assurer
que tous les raccords sont étanches. Lire le manuel
de l’opérateur pour les in struc tions d’opération et
d’entretien.
MISE EN MARCHE: Mettre tous les interrupteurs
de pompe en position ON. Les pompes se mettront
automatiquement en marche lorsque le niveau d’eau
atteindrait la hauteur appropriée.
ARRÊT: Tourner tous les interrupteurs en posi-
tion OFF.
ENTRETIEN: Vous révérer au manuel de
l’opérateur pour les procédures d’entretien.
PARA DETENER LA MAQUINA: Ponga todos
los interruptores a la posición OFF.
MANTENIMIENTO: Lea el manual de oper-
ación para conocer el completo procedimiento
de mantención.
SHUT DOWN: Turn switches off.
MAINTENANCE: Refer to operator’s manu-
al for complete maintenance procedures.
11-4009
0 0 0 0 0 0
89144580-45
HS1
HS2
HS3
HS4
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
18
89144580-14
PIPING CONNECTION DIAGRAM #1
Notes:
1. Connect G2 to G3 When Hydro-screen Option is Not Supplied
Rear View of Equipment
Hydro-Screen
G1
1-1/2"
Flex Hose
Sump
Pump
To Drain
2" Line
(3" if Underground)
Note 2
D2
A2
CLT-300
G3
(Alternate
Connection
Note 1)
E1
CLB-603A
A1
B1
D1
C1
3" Line
Slope 1"/Ft
Minimum
E2
Recycle
Holding Tank
B2
C2
1-1/2" Line
(2" if Underground)
1" Line
(2" if Underground)
1-1/2"
Line
G2
background
8.914-458.0-G • Water Maze CLB-603
19
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
CONNECTION SIZE TYPE MATERIAL DESCRIPTION ACTION
A1 1.5" SLIP PVC Infeed Pump Inlet
Connect A1 to A2
A2 1.5" NPT Polypropylene Feed Tank Outlet
B1 1" SLIP PVC Ozone Pump Outlet
Connect B1 to B2
B2 1" NPT Polypropylene Recycle Holding Tank Outlet
C1 1.5" SLIP PVC Transfer/Ozone Pump inlet
Connect C1 to C2
C2 1.5" NPT Polypropylene Recycle Holding Tank Outlet
D1 2" SLIP PVC Tank Bottom Drain
Connect D1, D2 to
Drain Manifold
D2 2" SLIP PVC Tank Bottom Drain
E1 3" NPT Polypropylene Gravity Flow Outlet
Connect E1 to E2
E2 3" NPT Polypropylene Gravity Flow Inlet
G1 1.5" NPT Flex Hose Hydro-Screen Inlet
Connect G1 to G2
G2 1.5" NPT Iron Sump Pump Outlet
PIPING CONNECTION TABLE DIAGRAM #1
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
20
89144580-15
PIPING CONNECTION DIAGRAM #2
Notes:
1. Connect G2 to G3 When Hydro-Screen Option is Not Supplied
Rear View of Equipment
Hydro-Screen
G1
G3 (Alternate
Connection
Note 1)
CLT-300
CLB-603A
CLB-30 CLT-600
24" Maximum Spacing
24" Maximum Spacing
E1
3" Line
E2
E3
3" Line
E4
E5
3"
line
E6
Recycle
Holding
Tank
B2
C2
Note 2
C1
1-1/2" Line
(2" if
Underground)
1" Line
(2" if Underground)
2" Line
(3" if Underground)
D1B1
A1
1-1/2"
Line
D2
Note 2
A2
G2
1-1/2" Flex
Hose
Sump
Pump
To Drain
H1
H2
background
8.914-458.0-G • Water Maze CLB-603
21
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
PIPING CONNECTION TABLE DIAGRAM #2
CONNECTION SIZE TYPE MATERIAL DESCRIPTION ACTION
A1 1.5" SLIP PVC Infeed Pump Inlet Connect A1 to A2
A2 1.5" NPT Polypropylene Feed Tank Supply Connect A1 to A2
B1 1" SLIP PVC Ozone Pump Outlet Connect B1 to B2
B2 1" NPT Polypropylene Ozone Pump Inlet Connect B1 to B2
C1 1.5" SLIP PVC Transfer/Ozone Pump Inlet Connect C1 to C2
C2 1.5" NPT Polypropylene Holding Tank Outlet Connect C1 to C2
D1 2" SLIP PVC Tank Bottom Drain
Connect D1, D2, D3 to
Drain Manifold
D2 2" SLIP PVC Tank Bottom Drain
D3 2" SLIP PVC Tank Bottom Drain (optional)
D4 2" SLIP PVC Tank Bottom Drain (optional)
E1 3" NPT Polypropylene Gravity Flow Outlet Connect E1 to E2
E2 3" NPT Polypropylene Gravity Flow Inlet Connect E1 to E2
E3 3" NPT Polypropylene Gravity Flow Outlet Connect E3 to E4
E4 3" NPT Polypropylene Gravity Flow Inlet Connect E3 to E4
E5 3" NPT Polypropylene Gravity Flow Inlet Connect E3 to E4
E6 3" NPT Polypropylene Gravity Flow Inlet Connect E3 to E4
G1 1.5" NPT Flex Hose Hydro-screen Inlet Connect G1 to G2
G2 1.5" NPT Iron Sump Pump Outlet Connect G1 to G2
H1 1.5" NPT PVC Circulation Inlet
(close gate valve)
Connect H1 to H2
H2 1.5" NPT Polypropylene Outlet from Tank Connect H1 to H2
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
22
PIPING CONNECTION DIAGRAM #3
NOTES:
1. Connect G2 to G3 When Hydro-Screen Option is Not Supplied
Rear View of Equipment
Hydro-Screen
G1
G3
(Alternate
Connection
Note 1)
CLT-300
CLB-603A
CLT-600
A2
1-1/2"
Flex Hose
Sump
Pump
To
Drain
Note 2
D2
1-1/2"
Line
A1
1-1/2" Line
(2" if Underground)
1" Line
(1-1/2" if
Underground)
2" Line
(3" if Underground)
E1
H1
B1
D1
C1
Note 2
D3
3" Line
E2
E3
3"
Line
Slope 1"/ft.
Minimum
1-1/2" Line
(2" if Underground)
B2
C2
E4
Recycle
Holding
Tank
24" Maximum Spacing
G2
H2
background
8.914-458.0-G • Water Maze CLB-603
23
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
PIPING CONNECTION TABLE DIAGRAM #3
CONNECTION SIZE TYPE MATERIAL DESCRIPTION ACTION
A1 1.5" SLIP PVC Infeed Pump Inlet Connect A1 to A2
A2 1.5" NPT Polypropylene Feed Tank Outlet Connect A1 to A2
B1 1" SLIP PVC Ozone Pump Outlet Connect B1 to B2
B2 1" NPT Polypropylene Ozone Pump Inlet Connect B1 to B2
C1 1.5" SLIP PVC Transfer/Ozone Pump Inlet Connect C1 to C2
C2 1.5" NPT Polypropylene Holding Tank Outlet Connect C1 to C2
D1 2" SLIP PVC Tank Bottom Drain
Connect D1, D2, D3
to Drain Manifold
D2 2" SLIP PVC Tank Bottom Drain
D3 2" SLIP PVC Tank Bottom Drain (optional)
E1 3" NPT Polypropylene Gravity Flow Outlet Connect E1 to E2
E2 3" NPT Polypropylene Gravity Flow Inlet Connect E1 to E2
E3 3" NPT Polypropylene Gravity Flow Outlet Connect E3 to E4
E4 3" NPT Polypropylene Gravity Flow Inlet Connect E3 to E4
G1 1.5" NPT Flex Hose Hydro-Screen Inlet Connect G1 to G2
G2 1.5" NPT Iron Sump Pump Outlet Connect G1 to G2
H1 1.5" NPT CPVC Circulation Inlet
(close gate valve) Connect H1 to H2
H2 1.5" NPT Polypropylene Circulation Outlet Connect H1 to H2
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
24
ELECTRICAL FIELD CONNECTION CLB-603A
Rear View of Equipment
89144580-9
CLT-600
CLB-30
CLB-603A
CLT-300
FS1
JB1
JB2
JB5
JB4
JB3
Ozone
Generator
FS3
Recycle
Holding
Tank
FS4
FS5
Sump Pump
background
8.914-458.0-G • Water Maze CLB-603
25
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
JUNCTION BOX WIRE NUMBER CONNECT TO FUNCTION
JB1 1040 Sump Pump Sump Pump 1/60/230 Volt
1060
JB1 1200 Ozone Generator Ozone Generator 1/60/230 Volt
1220
JB2 1731 FS1 Infeed Pump Control, NO (Black Float Switch)
1732
JB2 1320 FS5 Transfer Pump Permissive, NO
1794 (Black Float Switch)
JB3 1320 FS3 Rain Water Overfl ow Solenoid, NO
1581 (Black Float Switch)
JB3 1320 FS4 Fresh Water Makeup Solenoid NC
1610 (Gray Float Switch)
JB4 102L1 Power Source Electrical Power to CLB603
102L2 1/60/230 Volt, 15A
NOTE: Installations may not include all of the above components
ELECTRICAL FIELD CONNECTION TABLE CLB-603A
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
26
89144580-7
AIR CONNECTION DIAGRAM
CLT-300
CLB-603A
CLB-30 CLT-600
V2
R1 &
R2
V1
V3
V4
Recycle
Holding
Tank
NOTE:
The Model CLB-603A is equipped with an air pilot actuator mounted on the purge valve designated as V1 (shown above)
Valves V2, V3 and V4 must be connected to V1 as shown.
Note: Automatic purge valves V2, V3 and V4 are optional and may not have been supplied.
Rear View of Equipment
Air
Pressure
Regulator
R1
R2
R1: Pressure Regulator for Purge Drain Valves. Customer to Supply: 3 SCFM @ 60-100 PSI Air Pressure
R2: Pressure Regulator for Air Stone Diffuser. Customer to Supply: 1 CFM @ 60-100 PSI Air Pressure.
Plan View of
CLB-603A
Baseplate
background
8.914-458.0-G • Water Maze CLB-603
27
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-34
RECYCLE HOLDING TANK INSTALLATION
Alternate 3"
Connection
See
Note
#1
12"
12"
12"
12"
6"
FS3:
Rain Water Overfl ow
Black Float
(NO Contacts)
FS4
Fresh Water
Makeup Grey
Float
(NC Contacts)
FS5:
Permissive to
Start Transfer
Pump Black Float
(NO Contacts)
NOTE #1:
Locate 3" bulkhead at highest point on recycle holding tank while maintaining
a 1"/ft. slope on inlet pipe from Bio-System
3" Connection
1"
Connection
1-1/2"
Connection
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
28
Variable Speed Peristaltic Pump
TECHNICAL INFORMATION
Materials:
Squeeze Tubing Special synthetic rub ber
Strainer and
Injection Point Fitting PVC
Feed Rate: 1-7 or 8-45 GPD
Tubing Size: 1-7 or 8-45 GPD
Dimensions: Height = 5"
Width = 4"
Depth = 4 1/4"
Standard Accessories Provided with Pump:
Squeeze Tubing
Check Valve Assembly
Strainer with Weight
Bulkhead Fitting with Elbow
Electrical Rating:
20-265 VAC
7 W
50/60 Hz
Maximum System Pressure: 45 PSI
Installation
1. Suction Tubing: Take the 5 ft. length of 1/4" O.D.
tubing in clud ed, measure and cut the lengths
needed to run from pump head to the chemical
tank. Cut the tubing ends square.
Indicator Light
Cover
Screws
Pump Rollers
2. Connect Suction Tubing To Pump: Remove
compression fi tting. Feed tube through fi tting. Push
end of the tube on fi tting. Tighten fi tting rmly.
NOTE: To soften the end of the tubing, im merse
it in hot water.
3. Connect Suction Tubing To Strainer: In stall
strainer so it’s off the bottom of the chemical con-
tain er. Cut the suction tub ing to the length need ed.
Put weight on tubing. Push strainer end into tubing.
METERING PUMP
OPERATION
If not already done, put the end of the suction tub ing
into the chemical container, near the bottom.
Move the “ON-OFF” switch to ON.
Prime: To prime the pump and lines push the 3-way
switch to full speed.
Feed Adjustment: (ONLY A QUALIFIED WATER
MAZE SERVICE TECH NI CIAN SHOULD MAKE THIS
AD JUST MENT.) The feed adjustment is under the
cover plate. Remove the plate and turn the adjusting
screws clockwise to in crease feed or counterclockwise
to decrease feed.
METERING PUMPS
Chemical
Container
Suction
Tube
Discharge
Tube
Check Valve
Speed
Adjustment
Power
Cord
Strainer
Inlet
Squeeze
Tube
Speed
Adjusting
Screw with
Indexing
Mark
On-Off-Full
Speed Switch
(right or left
side)
Discharge
1 2
Strainer
End
Weight
Suction
Tube
background
8.914-458.0-G • Water Maze CLB-603
29
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
DANGER: DO NOT ATTEMPT TO FEED CHEMI-
CALS WITHOUT CONSULTING YOUR CHEMICAL
FEEDER DEALER OR CHEMICAL SUPPLIER.
DANGER: NE PAS TENTER D'ALIMENTER DES
PRODUITS CHIMIQUES SANS D'ABORD CON-
SULTER LE CONCESSIONNAIRE D'ALIMENTATION
EN PRODUITS CHIMIQUES OU LE FOURNISSEUR
DE PRODUITS CHIMIQUES.
CAUTION: Wear protective
gloves, goggles, and other
adequate protection for the
chemical hazard.
ATTENTION: Porter des gants
de protection, des lunettes
étanches et d'autres protec-
tions adéquates pour les ris-
ques chimiques.
Before replacing the pump head,
remove chemical from tubing as
follows:
1. Remove strainer from chemical tank.
2. Run pump until all chemical is removed from the
tubing.
FILLING THE CHEMICAL TANK: To avoid running out,
of chemical, follow a regular schedule of monitoring
chemical supply. Also inspect and clean the strainer
by fl ushing with a compatible liquid, as needed.
TUBING INSPECTION: Inspect all tubing regularly
and replace it if it is deteriorating.
REPLACING PUMP HEAD TUBING:
1. Remove compression fi ttings from the tubing at
the pump head.
2. Pull the suction and discharge tubing from the
pump head.
3. Remove the front cover of the pump.
4. Rotate the pump rollers to a vertical position.
5. Lift the inlet fi tting out of the housing.
6. Pull tube out while rotating the rollers clockwise.
7. Remove the outlet fi tting.
8. Install the inlet fi tting for the new tube assembly.
CAUTION: DO NOT LOSE THE BEARING FROM
THE CENTER HOLE IN THE BACK COVER.
ATTENTION: NE PAS DESSERRER LE PALIER
DE TROU CENTRAL DANS LA PLAQUE DU
COUVERCLE.
9. Press the tube into place in front of a roller while
rotating the roller assembly clockwise.
10. Install the outlet fi tting.
11. Reconnect the suction and discharge lines.
12. Install front cover.
CAUTION: Clear or transparent plastic tubing
should be replaced at least every three months
if exposed to the sun. Replace tubing yearly if
feeder is installed indoors.
ATTENTION: Un tube en plastique clair ou
transparent devrait être remplacé au moins
tous les trois mois s'il est exposé au soleil.
Remplacer le tube une fois par année si le dis-
positif d'alimentation est installé à l'intérieur.
INSPECT FOR LEAKAGE: Inspect the chemical sys-
tem daily for any signs of leakage. If leaking occurs
at tubing connections, tighten fi tting compression nut
nger tight. If leakage continues, remove pressure from
the system. Disconnect the tubing, trim ends square
and reconnect.
INSPECT FOR BLOCKED FLOW: Precipitates or
other chemical reactions cause injection points to clog.
If the type of chemical being fed eliminates the use of
ushing solution, the injection point must be inspected
at regular intervals. Strainers must be kept clean with
periodic back-fl ushing.
WARNING
PROTECTIVE
EYEWEAR AND
CLOTHING MUST
BE WORN.
METERING PUMP MAINTENANCE
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
30
METERING PUMP AND PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.749-855.0 Pump, Peristaltic, PR-7,
8-45 gpd 1
8.749-856.0 Pump, Peristaltic, PRS-1,
1-7 gpd
2 8.749-862.0 Tube, Squeeze, Santoprene,
PR-7,
* 8-45 gpd 1
8.749-864.0 Tube, Squeeze, Santoprene,
PRS-1,
* 1-7 gpd
3 8.749-860.0 Check Valve, PVC 1
4 8.749-857.0 Tubing, 1/4", PE, Black AR
5 8.749-863.0 Strainer, w/Welght 1
6 8.711-737.0 Tubing, 1/8", ID, Norprene AR
7 8.751-801.0 Faceplate, PRS-1/ PR-7 1
8 8.751-375.0 Roller Assembly, P 1
8-751-376.0 Roller Assembly, PRS-1 1
* Alternative tubing materials are available
1
2
3
6
8
7
4
5
background
8.914-458.0-G • Water Maze CLB-603
31
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
WARNING: Live electrical
contacts are exposed, so dis-
connect power fi rst and have
work performed by a qualifi ed
electrician.
AVERTISSEMENT: Les contacts
électriques sous tension sont
exposés, il faut donc d'abord
débrancher l'alimentation élec-
trique et confi er le travail à un électricien qualifi é.
Remove cover of the pump pressure control switch to
allow access to the two nuts used to adjust the pump
operating pressure. The pressure switch on Water
Maze equipment is set at the factory and should not
have to be adjusted at start-up, but will need to be
verifi ed at start up and maintained regularly at least
monthly.
1. The nut on the larger spring in the pump pressure
switch, adjusts the pump cut in (cut on) and pump
cut out (cut off) pressures simultaneously.
2. The nut atop the smaller spring in the pump pres-
sure switch only controls the cut out range and
is used to narrow or widen the gap between the
pump cut in and cut out pressures.
3. To cycle the pump less frequently, the gap should
be as wide as possible while still allowing the
pump to shut off quickly when all outlets are
closed. Adjust the smaller spring to widen the
gap between pump in and out (on and off). 40-
45 PSI (CLP, Rec2-20) or 30 PSI (EC1-300A) is
desirable. Adjusting the larger spring should not
be necessary.
4. When making pressure switch adjustments, make
sure all pump outlets are off or closed, except for
the one outlet valve used to relieve and build pres-
sure while making pressure switch adjustments.
PRESSURE TANK
OPERATION
WARNING! When the tank
has been in service and a
change to a higher pre-
charge pressure is neces-
sary because of a required
change in the pressure
switch setting, failure to
fol- low instructions below can
cause a rupture or explosion
and could cause serious or
fatal personal injury and/or property damage.
AVERTISSEMENT: Après avoir effectué l'entretien
du réservoir, il est nécessaire de passer à une
pression de précharge supérieure en raison d'un
changement requis du paramètre du pressostat;
le non-respect des directives ci-dessous peut
causer une rupture ou une explosion, et pourrait
causer des lésions corporelles graves ou fatales
et/ou des dommages à la propriété.
Do not adjust or add pressure if there has been a
loss of air.
Do not adjust the pre-charge pressure if there is
visible exterior corrosion.
Do not adjust the pre-charge pressure if there has
been a reduction of the pump cycle time or the
pre-charge pressure compared to its initial setting.
A reduction in pump cycle time can result from
loss of tank corrosion and any re-pressurization
or additional pressure could result in rupture or
explosion.
Pressure tank pressure is factory set but will have
to be checked regularly (at least monthly). Use
an air pressure (tire) gauge. Before checking air
pressure on the pressure tank, purge all water out
of the tank by turning the pump on and pumping
all water out of the pressure tank.
1. Our transfer pump water systems use a water
pressure tank and water pump with these two
pressure operation ranges:
Cut in (start pumping): 20 PSI
Cut out (stop pumping): 30 PSI (EC1-300A)
Cut out (stop pumping): 40-45 PSI (CLP, REC2-20)
2. Typical factory set air pressure on bladder-type
residential water pressure tanks are shipped from
the factory with a standard pre-charge of:
18 psig for models WX-101 and WX-102
18 psig for models WX-103 and WX-203
18 psig for models WX-205 and WX-350
3. Set the well tank air pressure to 2 PSI below the
pump pressure switch cut-in pressure. This is usu-
ally 18 PSI.
WARNING
RISK OF
EXPLOSION:
FOLLOW
INSTRUCTIONS
WHEN CHANGING
PRESSURE
WARNING
RISK OF
ELECTRIC SHOCK:
USE CAUTION
WHEN HANDLING.
PRESSURE SWITCH AND PRESSURE TANK OPERATION
89174360-14
Controls
Cut In/Cut Out
Controls
Cut Out Range
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
32
ATTENTION: Ne jamais regarder la lampe d'ozone
non protégée pendant l'utilisation de la machine.
Cette lampe peut causer de graves dommages
aux yeux et à la peau. Le voyant lumineux sera
vert (faible) ou éteint lorsque l'appareil fonctionne
correctement. Le voyant passe à un vert vibrant
lorsqu'une défaillance est présente. Consulter
la description du produit pour l'emplacement du
témoin lumineux.
Testing the Lamp:
(See Ozone Generator Testing Illus.)
To test the ozone lamp, use a voltmeter set on ohms.
First remove the ozone cover and unplug the lamp
plug from the ozone lamp. NOTE: There are two
laments - an upper and a lower - inside the lamp.
Place one of the voltmeter leads on one of the lamp
prongs and, with the other lead, touch all of the three
remaining prongs. If continuity is not achieved on both
upper and lower fi laments, replace the ozone lamp
(Part #6-0534).
To test the power pack, use a voltmeter set on the
correct voltage (240V). Place one of the voltmeter
leads into the lamp plug where the white wire goes
into it and plug the other voltmeter lead into the lamp
plug where the blue wire goes into it. If no voltage is
present replace the ozone ballast (Part #6-05232 -
240V). When ordering an ozone ballast, you also need
the 4-pin connector (Part #6-05233).
Replacing the lamp: (See Ozone Generator Break-
down)
89144580-39
Ozone
Lamp
Prongs
Ballast
OZONE GENERATOR TESTING
Four Pin
Connector
OZONE GENERATOR
Ozone...Nature’s Purifi cation Agent:
Ozone is produced in nature or artifi cially by man. In
the earth’s atmosphere, ozone is formed when oxygen
is exposed to ultraviolet light or an electrical charge
as during thunderstorms. Ozone’s primary function in
nature is to purify the air we breathe and screen us
from harmful rays of the sun. In a similar fashion, the
CLB system uses ozone to disinfect water because
Ozone has a number of characteristics that make it
ideal for water treatment.
Ozone’s Characteristics:
Ozone is well suited for water treatment, and it’s unique
characteristics are described below:
Ozone works up to 3,000 times faster than
chlorine to kill bacteria and destroy harmful
microorganisms.
Ozone is a more powerful oxidizing agent than
chlorine and bromine, having a better ability to
remove water contamination.
Ozone will not form harmful by-products, like
THM’s (a problem in drinking water), or chlo-
ramines, (by-products of chlorine that are re-
sponsible for odors, skin irritations and burning
eyes.)
Ozone will not alter the water’s pH, reducing pH
uctuations.
Ozone coagulates small particles in water so
clarity is dramatically improved.
Ozone acts as a deodorizer removing unpleas-
ant odors from water.
How the CLB Ozone System Works:
Because ozone is unstable, it cannot be packaged and
used at a later date. For this reason, ozone is always
produced where it is utilized.
Point-of-use ozone generation is simple. This powerful
disinfectant is produced from ambient air surrounding
the generator using special ultraviolet lamps located
inside the system’s cabinet. To generate the ozone,
air movement is created through the use of an air
compressor or water venturi. As air passes over
these unique lamps, the oxygen contained in the air
is converted. The resulting ozone gas is subsequently
introduced to the water in the inlet pipeline, where
oxidation and disinfection immediately take place.
Ozone Generator Maintenance:
CAUTION: Never look at the unshielded ozone
lamp while operating the machine. This lamp can
cause severe eye and skin damage. The indica-
tor light will be a dim green or not lit at all when
operating properly. The light glows a bright green
when there is a failure. See product description
for location of the indicator light.
background
8.914-458.0-G • Water Maze CLB-603
33
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
OZONE GENERATOR FOUR TUBE
Power In
LEGEND:
B = Black
W = White
R = Red
G = Green
Y = Yellow
BL = Blue
89144580-37
Transformer
RYW
Transformer
RYW
Transformer
RYW
Transformer
RYW
B
B
Control
Switch
BLBLBL BL
B
W
G
Ground
W
B
W
B
W
B
W
B
Indicating Lights
NOTE:
Green Indicating Light Operation
Bright Continuous Light Indicates
UV Light of Ballast Defective
Dim Continuous Light Indicates
Proper Operation
Ozone LightOzone Light Ozone LightOzone Light
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
34
Lamp replacements are available from your Water
Maze Dealer should they need to be replaced. Simply
turn off the power to the CLB at the breaker, remove
the screws on the power pack cover and remove the
cover. Disconnect the plug on the end of the ozone
lamp. Now, loosen the lamp holder locking ring from
around the end of the lamp by turning it counterclock-
wise and remove it. Remove the lamp by grabbing
the rubber bushing around the end of the lamp and
pulling it straight out. Remove the rubber bushing from
the lamp and install it on your new lamp, making sure
the outer edge of the bushing is fl ush with the outer
edge of the silver end cap on the lamp. Now, slide the
lamp back into the reaction chamber. The lamp holder
may now be reinstalled and tightened. Reinstall the
plug onto the lamp and replace the power pack cover.
CAUTION: Keep the lamp free of fi ngerprints and
dust particles by only handling the metal end caps
on the lamp. You can clean the lamp with rubbing
alcohol and a soft cloth. A dirty lamp will not allow
maximum ozone output.
ULTRAVIOLET LIGHT
COMPLIANCE
Ultraviolet Light Safety Requirements
The device used in this product is a Class 1 certifi ed
ozone generator product. Operating this product outside
specifi cations or altering its original design may result
in hazardous radiation exposure, and may be consid-
ered an act of modifying or new manufacturing of a laser
product under U.S. regulations contained in 21CFR
Chapter 1, subchapter J.
CAUTION: Avoid exposure to direct or
strongly refl ected germicidal ultraviolet
rays.
DO NOT STARE INTO BEAM.
ATTENTION: Éviter l'exposition aux rayons
ultraviolets germicides fortement réfl échis.
NE PAS REGARDER DIRECTEMENT LE FAIS-
CEAU.
DANGER: Ultraviolet radiation. Disconnect
Power Before Replacing Lamp.
ATTENTION: Radiation ultraviolette. Débrancher
l'alimentation avant de remplacer la lampe.
DANGER: Connect only to a circuit that is pro-
tected by Ground Fault Circuit Interrupt (GFCI).
DANGER: Raccorder uniquement à un circuit qui
est protégé par un disjoncteur différentiel de
fuite à la terre (DDFT).
Instructions for Disposing of Your UV
Light Tube
1. Do not break a UV light tube. Keep all tubes whole
if possible. If a UV light tube is accidentally broken,
wear gloves while picking up the pieces, and care-
fully dispose of them in a trash bag. Wipe the area
with a wet wipe, and put the wet wipe in the same
trash bag. Place the trash bag with broken pieces
inside another trash bag. Mark the bag with a sign
labeled, "Broken Mercury Light Bulb".
2. Remove the UV light tube from the Ozone Genera-
tor. Place the used tube in the trash bag, and place
that bag inside another trash bag. Seal the openings
and then tape a slip of paper on the outer bag labeled,
"Mercury LIght Bulb."
3. Take the used and /or broken mercury tube to your
nearest recycling bin for mercury light bulbs or take
this tube to a state-approved recycling center.
SPECIFICATIONS:
Energy Required 220V: 210VAC MIN., 230V MAX.,
.450AMP/Ballast
Power Consumption: 20 Watts
Average Lamp Life: 9,000 Hours
CENTRIFUGAL PUMP
Your centrifugal pump has been quality-built and engi-
neered to give you effi cient, dependable service. It is
equipped with union connectors to make installation
and future service easier.
The advanced design uses a single speed motor
which reduces operation and maintenance to simple,
common-sense procedures.
PUMP OPERATION
(Ozone, Infeed, or Transfer)
WARNING: Do not touch
pumps, pump motors, water
or discharge piping when the
pumps are connected to elec-
trical power. Do not handle a
pump or pump motor with wet
hands or when standing on a
wet or damp surface or in water.
WARNING
RISK OF ELECTRIC
SHOCK: USE CAUTION
WHEN HANDLING.
OZONE GENERATOR
background
8.914-458.0-G • Water Maze CLB-603
35
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
WARNING
RISK OF ELECTRIC
SHOCK: USE
CAUTION WHEN
HANDLING.
Never touch a pump or discharge piping when a
unit is operating or fails to operate. Always dis-
connect the pump cord (power) before handling.
1. The shaft seal depends on water for lubrication.
Do not operate the pump unless there is water.
Dry running (pump not pumping water) will cause
seal damage and eventual pump failure.
2. The motor is equipped with an automatic reset
thermal protector. This means if the temperature in
the motor should rise unduly, the switch will cut off
all power before damage can be done to the motor.
When the motor has cooled suffi ciently, the switch
will reset automatically and restart the motor. If the
protector trips repeatedly (cycling on protector) the
pump should be removed and checked as to the
cause of the diffi culty. Low voltage, long extension
cords, clogged impeller, very low head or lift, etc.,
could cause cycling. Cycling of the protector will
cause eventual motor burnout.
PUMP
MAINTENANCE
(Sump Pump)
WARNING: Before attempting
to service, disconnect power
from unit. Do not handle the
pump with wet hands or when
standing on a wet or damp
surface or in water. Failure to follow precautions
can result in personal injury and /or property
damage.
AVERTISSEMENT: Ce produit et les accessoires
peuvent contenir un produit chimique reconnu
dans l'État de la Californie comme pouvant
causer le cancer, des anomalies congénitales et
d'autres problèmes liés à la reproduction. Pour
en savoir plus sur ce règlement. Le non-respect
des précautions peut mener à des lésions
corporelles et/ou des dommages à la propriété.
NOTE: Only qualified electricians or servicemen
should attempt to repair this unit. Improper repair and/
or assembly can cause an electrical shock hazard.
1. Bearings in this unit are pre-lubricated. No ad-
ditional lubrication is necessary.
2. Cleaning - Occasionally clean the sump pit and pump
if dirt or foreign matter accumulate. Small stones,
gravel, sand, dirt, silt, etc. can clog and damage
the pump and pump seal, eventually causing pump
failure.
3. Disassembly of the motor prior to expiration of the
warranty will void the warranty. It may also cause
internal leakage and damage to the unit. If repairs
are required, return the pump to a local service
station.
4. If the motor has been disassembled or the switch
chamber opened after the warranty expiration
date, the O-rings and gaskets must be replaced.
Care must be taken to assure that the seals, the
switch cover and air tube gaskets do not leak.
5. The pump should be checked for proper opera-
tion weekly or monthly by watching the operation
of the pump. If anything has changed since the
pump was new, the pump should be examined,
and repaired if necessary.
Operation
The pH of the water stream is controlled automatically
by the digital controller. The controller receives input
from the pH sensor on the pH level of the digester tank.
The level of pH being sensed, and the requested level
programmed in the controller will determine if output
from the controller is sent to the feed pumps. If pH
adjust is needed, the output will turn the corresponding
feed pump on. This will inject the required pH until the
programmed level is reached and feed pump will stop.
Start-Up
Turn switch on right side of controller to the "ON"
position.
Feed Mode
The feed mode for the sanitizer of pH can be set to
"OFF", manual or Automatic. Set to Automatic. To
select the desired feed mode, press [pH] until the
corresponding LED indicator light is illuminated. There
is a short delay before activation. Note: Holding the
switch for more than 5 seconds resets the setpoint and
calibration for [pH] to original factory values.
pH Calibration
To calibrate the pH, use a reliable, fresh test kit (Phenol
Red). Note the value of the pH and compare it to the
display value.
To change the pH calibration:
• press [CALIBRATION],
• Press [pH]: the display fl ashes,
• Use the [UP] and [DOWN] arrows to adjust the
pH value,
• Press the [CALIBRATION] again to save the
new value.
pH Control Setpoint
The pH setpoint is preset at 7.0. To change the pH
control setpoint:
• Press [SETPOINT],
• Press [pH]: the display fl ashes,
OPTIONAL pH DIGITAL CONTROLLER - MODEL 240
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
36
• Use the [UP] and [DOWN] arrows to adjust the
pH value,
• Press [SETPOINT] again to save the new value.
Out-of-Range Alarms
The out-of-range alarms is factory set at 6.0 to 9.0 for
pH. If the pH limits are exceeded, the red LED alarm
ashes and the pH feeder continues.
To change an alarm limit:
• Press [LOW LIMIT] or [HIGH LIMIT],
• Use the [UP] and [down] arrows to adjust the value,
• press [LOW LIMIT] or [HIGH LIMIT] again.
CAUTION: Increasing the out-of-range limits may
cause overfeeding of chemicals.
ATTENTION: L'augmentation des limites hors de
portée pourrait entraîner la suralimentation en
produits chimiques.
pH SENSOR MAINTENANCE
The controller is virtually maintenance free. The en-
closure and front panel can be cleaned with a soft
cloth moistened with a mild soap and water solution
or a glass cleaner. Do not use abrasives or harsh
chemicals.
Sensor Testing
To test the sensors on line, carefully add a small
amount of white vinegar or dilute acid solution in a
clean jar and insert sensor. After a few minutes the
pH reading should go DOWN.
If you get no response or a sluggish response, clean
or replace the sensors as soon as possible.
Sensor Cleaning
The sensor tips must be kept
clean and free from chemical
deposits and contamination to
function properly. After saturation
in the waste stream, the sensors
may need to be cleaned on a
weekly or monthly basis depend-
ing on the water quality and other
facility-specifi c characteristics.
Slow response and inconsistent
readings are indications that the
sensors are in need of cleaning.
To clean a sensor, carefully re-
move it from the compression
tting or holding bracket. Clean
the tip of the sensor with a mild
liquid detergent (Joy
®
, etc) solu-
tion. Rinse with fresh water and
OPTIONAL pH DIGITAL CONTROLLER - MODEL 240
66-122
Plastic
Cap with
Water
soak the sensor in a mild acid solution for fi ve minutes.
Rinse with fresh water and reinstall the sensor.
Sensor Replacement
For preventative maintenance it is also recommended
to replace the sensors on an annual basis or as per-
formance diminishes.
Sensor Storage
Extended exposure to atmospheric conditions will
cause the sensor tips to dry out. Always remove and
properly store the sensors if they are to be winterized
or inactive.
Store the sensors with the original cap provided, mak-
ing sure that each cap is fi lled with clean water. If the
storage containers have been misplaced, store the
sensors individually in small glass or plastic containers
with clean water covering the sensor tips.
background
8.914-458.0-G • Water Maze CLB-603
37
WATER TREATMENT SYSTEM
Troubleshooting Guide
TROUBLESHOOTING - PH SENSOR
All controllers are manufactured to the highest quality standards and thoroughly tested before leaving the fac-
tory. State-of-the-art designs and fabrication technology should ensure years for trouble-free operation.
PROBLEM
SOLUTION
NO LIGHTS
ARE ON WITH
POWER ON
Check for power going to controller.
Check for a damaged power connector.
Check internal fuse (1A slow blow) marked F3 on control board.
ILLOGICAL pH
VALUE DISPLAY
The sensor cable connections may be reversed. Verify that the sensor cables are
properly connected to their respective BNC connectors on the controller unit.
pH FEEDER
DOES NOT
ACTIVATE
Verify that the acid/base feed jumper JP14 on the control board is properly set.
Make sure the AUTO feed light for pH is on.
Check the pH relay fuse (5A slow blow) marked F2 on control board
pH REQUIRES
FREQUENT
CALIBRATION
Clean or replace the sensor as outlined in the maintenance section.
INCONSISTANT
OR SLOW pH
READINGS
Verify that the sensor cables are properly connected to their respective BNC con-
nectors and the controller unit.
Clean or replace the sensor as outlined in the maintenance section.
Replace the sensors if needed.
CHEMICAL
FEEDER RUNS
CONTINUOUSLY
Make sure the AUTO feed mode is selected.
Verify that the chemical feeders are properly connected to their respective con-
nectors or controller unit.
background
8.914-458.0-G • Water Maze CLB-603
WATER TREATMENT SYSTEM
Troubleshooting Guide
38
PROBLEM POSSIBLE CAUSE SOLUTION
INFEED PUMP
DOES NOT
OPERATE
Low level in CLT-300 tank Check level in CLT-300 tank. Pump will not
operate at low water level.
LS1 has improper electrical
connection to JB#2
Connect LS1 to connections located in
junction box #2.
Control panel pump switch is in the
OFF position
Confi rm that control panel pump switch is
in the ON position.
OZONE PUMP
DOES NOT
OPERATE
Ozone timer is not set properly Refer to instructions on setting ozone
pump timer.
Recycle holding tank has low water
level
Low water level will not allow the ozone
pump to operate. Raise level in recycle
holding tank.
Control panel pump switch is in the
OFF position
Confi rm that control panel pump switch is
in the ON position.
TRANSFER PUMP
DOES NOT
OPERATE
Recycle holding tank has low water
level
Low water level will not allow the transfer
pump to operate. Raise level in recycle
holding tank.
Water panel hand valve (V4 or V5)
open but pump does not start, or hand
valve is closed but pump does not stop
Pressure switch (PSI) is out of
adjustment. Readjust.
Control panel pump switch is in the
OFF position
Confi rm that control panel
pump switch is in the ON position.
TROUBLESHOOTING - INFEED, OZONE AND TRANSFER PUMP
background
8.914-458.0-G • Water Maze CLB-603
39
WATER TREATMENT SYSTEM
Troubleshooting Guide
TROUBLESHOOTING - PUMP
PROBLEM POSSIBLE CAUSE SOLUTION
PUMP DOES
NOT TURN ON
Circuit breaker shut "OFF" Turn "ON" circuit breaker.
Accumulation of trash on fl oat Clean fl oat.
Float obstruction Check fl oat path and provide clearance.
Defective switch Have pump serviced by authorized service center.
Defective motor Have pump serviced by authorized service center.
Low line voltage If voltage under recommended minimum, check
size of wiring from main switch on property. If OK,
contact power company.
PUMP WILL
NOT SHUT OFF
Float obstruction Check fl oat and fl oat rod path. Provide clearance.
Pump is air locked
(Transfer and Infeed Pump)
Shut power off for approximately 1 minute, then
restart. Repeat several times to clear air from pump.
Defective fl oat switch Disconnect switch, check with ohmmeter.
PUMP RUNS BUT
DOES NOT
DISCHARGE
LIQUID
Lift too high for pump Check rating table.
Inlet to impeller plugged Pull pump and clean.
Low line voltage If voltage under recommended minimum, check
size of wiring from main switch on property. If OK,
contact power company.
Clogged impeller Remove housing, unclog.
Faulty motor protector Replace pump.
PUMP DOES NOT
DELIVER RATED
CAPACITY
Low voltage, speed too slow Check for proper supply voltage to make
certain it corresponds to nameplate voltage.
Impeller or discharge pipe
is clogged
Pull pump and clean. Check pipe for scale or
corrosion.
Impeller wear due to abrasives Replace worn impeller.
PUMP CYCLES
CONTINUALLY
Low line voltage If voltage under recommended minimum, check
size of wiring from main switch on property. If OK,
contact power company.
Worn or defective pump parts
or plugged impeller
Replace worn parts or entire pump. Clean parts if
required.
Pump air locked Turn pump "ON" and "OFF" several times. Fill hose
manually with water.
background
8.914-458.0-G • Water Maze CLB-603
WATER TREATMENT SYSTEM
Troubleshooting Guide
40
TROUBLESHOOTING - PUMP MOTOR
PROBLEM POSSIBLE CAUSE SOLUTION
MOTOR WILL
NOT RUN
Disconnect switch is "OFF" Be sure switch is on.
Breaker is tripped Reset breaker.
Starting switch is defective Replace starting switch.
Wires at motor are loose, discon-
nected or wired incorrectly
Refer to instructions on wiring. Check and tighten
all wiring.
Pressure switch contacts are dirty
(Transfer Pump)
Clean by sliding piece of plain paper (or crocus
cloth) between contacts.
MOTOR RUNS
HOT AND
OVERLOAD
KICKS OFF
Motor is wired incorrectly Refer to instructions on wiring.
Voltage is too low Check with power company. Install heavier wiring if
wire size is too small. See wiring instructions.
Defective fl oat switch Disconnect switch, check with ohmmeter.
MOTOR RUNS
BUT NO WATER
IS DELIVERED
Pump in a new installation did not
pick up prime through:
a. Improper priming a. Re-prime (3 or 4 times may be needed) by
stopping and starting motor several times.
b. Air leaks b. Check all connections on suction line.
Pump has lost its prime through:
a. Air leaks a. Check all connections on suction line, air
volume control, jet and shaft seal.
b. Water level below suction of
pump
b. Lower suction line into water and re-prime.
Check valve is stuck
in closed position
Replace check valve.
Pipes are frozen Thaw pipes. Bury pipes below frost line. Heat
pipes below frost line. Heat pit or pump house.
background
8.914-458.0-G • Water Maze CLB-603
41
WATER TREATMENT SYSTEM
Troubleshooting Guide
PROBLEM POSSIBLE CAUSE SOLUTION
VALVE LEAKS
WHEN "OFF"
Dirt or debris on diaphragm
seat
Clean diaphragm seat.
Solenoid not fully closed after
manual operation
Turn solenoid clockwise to fully seated position.
Solenoid O-ring damaged or
twisted
Turn off water, inspect O-ring. Reseat if twisted,
replace if damaged.
Diaphragm damaged Turn off water, remove bonnet screws and
inspect diaphragm for nicks or damage NOTE:
Diaphragm has one bleed hole molded into it.
Replace, if necessary, with diaphragm kit.
Dirt interfering with solenoid
operation
Turn off water, remove solenoid and fl ush seat-
ing surface in bonnet and at bottom of solenoid
with water.
Solenoid damaged Turn off water supply and replace solenoid.
WATER WON'T
SHUT OFF
Valve in manual "ON" position Turn solenoid clockwise to "OFF" position.
Diaphragm bleed hole blocked Use Manual Flush Mode. Turn water supply
"OFF" and immediately back "ON" to clear
blockage. If still blocked, turn off water and
inspect diaphragm looking for blockage.
Damaged solenoid Turn off water supply and replace solenoid.
LOW OR
INADEQUATE
FLOW CONDITION
Gate valve not fully open Open gate valve fully.
Pipeline blockage Clear pipeline.
VALVE WON'T
TURN ON
ELECTRICALLY
No power to solenoid Make sure solenoid has power.
Low voltage Make sure there is 120 volts.
No water pressure Make sure water pressure is available to valve.
Turn off water, without cutting wires, unscrew
and swap solenoids between valves. Turn on
water and test again. If problem stems from the
solenoid, replace solenoid.
TROUBLESHOOTING - WATER SOLENOID
background
8.914-458.0-G • Water Maze CLB-603
WATER TREATMENT SYSTEM
Troubleshooting Guide
42
PROBLEM POSSIBLE CAUSE SOLUTION
CRACKED
OR BROKEN
STATIONARY
SEAT (CERAMIC)
Seal ran dry and heated up.
When liquid reached seal faces
it was cooler, causing thermal
cracks
Check to insure seal chamber is full of liquid be-
fore starting pump. On high temperature applica-
tion insure proper fl ushing at seal faces.
CARBON WASHER
SCORED AND
GROOVED
Dirty system Have system cleaned and fl ushed. Consider use
of Tungsten Carbide or Silicon Carbide Rings.
CARBON
WASHER WORN
UNEVENLY
Seal improperly installed Check installation instructions for proper
assembly.
BUNA DIAPHRAGM
HARD BRITTLE.
RAPID CARBON
WEAR.
Air leak on suction side of pump Check cover gasket, hand knobs, hose, clamps,
etc. Replace or tighten as necessary.
DIAPHRAGM
SOFT AND STICKY;
APPEARS TO
BE DISSOLVING.
Bellows not compatible with
material being pumped
Consult dealer for recommendation advising of
pumpage and temperature.
TROUBLESHOOTING - WATER SEALS
background
8.914-458.0-G • Water Maze CLB-603
43
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
DAILY MAINTENANCE
To keep your Bio-System in peak performance you
need to perform minimal daily maintenance. This
service is best performed each morning before using
the wash area..
Check and clean catch basin and trench.
Empty the debris dumpster.
Wash down front and back of hydro-screen, prefer-
ably with a pressure washer.
WEEKLY MAINTENANCE
Check that purge drain valves work properly.
Check that timers are set properly.
MONTHLY MAINTENANCE
Monthly maintenance for the Bio-System and re-
plenishment of BioStax 1800 is required. Schedule a
regular day and time each month to perform the main-
tenance. Record your maintenance in the monthly log
to provide a record in the event of an inspection.
Replenish BioStax 1800.
Replenish BioNutrient.
Check the automatic microbe dispenser pump and
make sure the tubing is not cracked or worn. Re-
place tubing if required (every 6-12 months). Clean
screen in tubing going in microbe bucket.
Visually inspect external hoses and fi ttings.
Confirm pressure switch setting on transfer
pump.
CLB MAINTENANCE
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
44
CLB MAINTENANCE
DAILY WEEKLY
MONTHLY
BI-YEARLY
Check pits for water level (Overfl ow/dry).
X
Check for voltage to machine
and that control panel switches are on.
X
Check all plumbing for leaks.
X
Check inlet fl ow meter for
proper fl ow. Clean meter if needed.
X
Check that inlet and discharge
manifold hoses and valves are in proper position.
X
Check ozone generator bulb.
Bright light-replace. Dim light good.
X
Clean and test pH probe if applicable*.
X
Suction pits of sludge and debris.*
X
Check and clean sump pump of dirt and debris.*
X
Clean fl oats in sump if accumulating dirt or grease. *
X
Check fl oat wires for cuts or frays.
X
Check and clean chemical injectors.
X
Check tubing on pH controller for splits or cracking.
X
Check standard cubic feet per
hour (SCFM) on ozone generator.
X
Check surge tank pressure.
X
Check transfer pump switch settings.
X
Open drain valve to purge solids.
X
Empty debris dumpster
X
Pressure wash front and back of debris dumpster.
X
Clean trench
X
Check timers for proper settings
X
Replenish BioStax 1800 and BioNutrient if applicable*
X
* Note: this is a guide. Depending on your wash load these items may have to be done more or less often.
background
8.914-458.0-G • Water Maze CLB-603
45
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-22
CLB-603 COMPONENT ASSEMBLY EXPLODED VIEW
Optional pH
Sensor & Bracket
Assy.
For Detail
See Opt. Oil
Skimmer
Sludge Tub
Assy. Illus
For Detail
See Opt.
Oil Skimmer
Sludge Tub
Assy. Illus
Recycle
Tank
Accessories
Included
with
CLB-603
Field
Installed
1
2
12,13,14
1
24
3
25
26
2
34
34
5
20
35
38
41
39
39
40
38
41
38
41
36
37
8
6
22
29
21
30
31,32,
33
23
4
16
18
15
17
19
11
10
9
7
27
28
25
26
2
20
For
Details See
Air Stone
Assembly
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
46
ITEM PART NO. DESCRIPTION QTY
1 8.913-151.0 Panel, Front Top, w/Cutout for pH
Controller (Option) 1
8.913-163.0 Panel, Front Top w/o Cutout for
pH Controller 1
2 9.802-071.0 Trim, Black 10.33 ft
(option) 14.33 ft
3 9.802-765.0 Screw, 1/4" x 1/2" BH SOC CS 12
4 9.802-793.0 Nut, Cage, 1/4" x 16 Ga 11
5 8.913-148.0 Front Panel, Bottom, Mild Steel 1
6 8.913-147.0 Control Panel, Mild Steel 1
7 8.913-155.0 Tank Stand 600, Mild Steel 1
8 8.913-146.0 Base Plate 1
9 8.902-236.0 Cone, 3/16 w/Holes 1
10 8.719-177.0 Tank, 600 Gal w/Lid 1
11 8.706-676.0 Plastic, Eofi ll 36 lb.
8.707-435.0 Bag, Pre-sewn 6
12 9.802-696.0 Nut, 10/32 Keps, SS 8
13 9.802-699.0 Screw, 10/32" x 3/4", Slot Pan 8
14 8.706-648.0 Handle, Sandpot Lid 3
15 8.718-854.0 Nut, 6/32, Keps 12
16 9.802-747.0 Screw, 6/32, Keps 12
17 8.716-905.0 Sensor, PH (Option) 1
18 8.706-568.0 Handle, Rubber w/Keeper 3
19 8.913-085.0 Bracket, PH (option) 12
20 8.900-841.0 Label, Water Maze 2
21 8.711-943.0 Bucket, 6-1/2 Gal 2
22 8.711-944.0 Lid, 6-1/2 Gal 2
23 8.900-522.0 Label, Warning, No Stand 1
24 9.800-016.0 Label, Warning, Electrical 1
25 8.901-222.0 Label, Microbe Pump 1
26 8.901-223.0 Label, Nutrient Pump 2
27 8.901-224.0 Label, pH Controller 1
28 8.901-225.0 Label, pH Pump 1
29 9.841-665.0 Label, Biostax 1800 1
30 8.900-615.0 Label, Bio-Nutrient 1
31 9.800-013.0 Label, Assembled, USA,
Intended for Indoor use 1
32 9.800-034.0 Label, Clear Lexan 1
33 Label, ETL 1
34 9.802-064.0 Grommet, Rubber Nozzle 2
(option) 1
Not Shown
CLB-603 COMPONENT ASSEMBLY PARTS LIST
ITEM PART NO. DESCRIPTION QTY
35 8.706-483.0 Bulkhead, 3" Ft x Ft, Polypro 1
36 8.706-484.0 Bulkhead, 1" Ft x Ft, Polypro 1
37 8.706-490.0 Bulkhead, 1-1/2" Ft x Ft,
Polypro 1
38 8.750-743.0 Bulkhead, 1/2" NPT Polypro 3
39 8.716-142.0 Float Switch, Black, NO 2
40 8.716-143.0 Float Switch, Gray, NC 1
41 9.802-514.0 Strain Relief, LG Tite 3
RECYCLE TANK
ACCESSORIES
background
8.914-458.0-G • Water Maze CLB-603
47
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-20
24
33
Field
Installed
See CLB-603
Dimension
Page for
Layout
Dimensions.
6
10
22
CLB-603 AIR STONE ASSEMBLY EXPLODED VIEW
23
25
30
8
7
5
11
4
19
12
18
16
2
1
27
21
20
6
9
9
34
32
3
3
13
13
14
15
19
28
29
31
17
26
16
4
11
11
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
48
CLB-603 AIR STONE ASSEMBLY EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.711-733.0 Tubing, 3/8" x 1/2, Vinyl 10 ft
2 8.709-069.0 Clamp, Screw #4 3
3 8.706-780.0 Nipple, 1/4" Hex 2
4 9.802-254.0 Hose, 1/4" Push-on 16 in
5 8.706-878.0 Nipple, 1/4" Pipe x 1/8" Pipe 3
6 8.706-407.0 Bushing, 1/2 x 1/4 MT x FT 3
7 8.706-393.0 Coupling, 1/2" SCH 80 1
8 8.712-417.0 Diffuser Stone, Fine Pore,
1/2" NPT 3
9 8.750-743.0 Bulkhead, 1/2" Polypro 3
10 8.707-016.0 Elbow, 1/4 NPT x 3/8,
Push-On, 90° 1
11 6.390-126.0 Clamp, Hose 6
12 8.913-157.0 Bracket, Aerator 1
13 8.706-841.0 Tee, 1/4" Female, Pipe 2
14 9.802-064.0 Grommet, Rubber 3
15 8.919-140.0 Bracket, Air Stone 3
16 8.706-941.0 Hose Barb, 1/4" x 1/4" MPT 3
17 9.802-788.0 Nut, 3/8, Whiz Loc 8
18 8.706-409.0 Adapter, 1" MT x SLIP, PVC 2
19 8.706-366.0 Pipe, PVC 80, 1" x 48" 2
20 9.802-721.0 Bolt, 3/8 x 1", HH, NC, SS 8
21 9.802-808.0 Washer, 3/8", Flat, SS 8
22 8.706-483.0 Bulkhead, 3", FT x FT,
Polypro 1
23 8.706-454.0 Adapter, 3", Slip x MT,
PVC 40 1
24 8.706-437.0 Tee, 3" x Slip x Slip x Slip,
PVC 40 1
25 8.706-368.0 Pipe, 3", PVC 40 4 in
26 8.749-860.0 Check Valve, PVC
(w/pH Controlller) 1
ITEM PART NO. DESCRIPTION QTY
27 8.707-355.0 Valve, 3/8, Tubing,
Check MPC P/N 1
28 8.718-619.0 Bolt, 5/16" x 3/4"" NC,
GR 5 SS 6
29 9.802-805.0 Washer, 5/16" Flat, SAE, SS 6
30 9.802-511.0 Cable Tie, 11" 2
31 9.802-777.0 Nut, 5/16" ESNA, NC, SS 6
32 8.749-861.0 Bulkhead, 3/8 PVC,
w/Elbow, (w/pH Controller) 1
33 8.706-368.0 Pipe, 3", PVC 40 22 in
(Customer Installed)
34 8.749-857.0 Tubing, PE, 1/4, BLK,
1/4" x 7 ft 2
Not Shown
background
8.914-458.0-G • Water Maze CLB-603
49
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-10
See
CLB Air
Components
Exploded
View
Optional pH
Injector
(Enlarged
View)
57
13
51
15
22
14
15
14
49
50
37
11
10
41
18
12
11
44
11
26
25
40
31
37
45
13
33
52
4
34
47
5
36
35
4
52
38
52
43
38
20
47
47
33
56
4
35
36
16
See
CLB Air
Components
Exploded
View
See
CLB Air
Components
Exploded
View
31
28
28
41
25
40
34
4
52
33
52
32
52
31
6
27
27
1
39
42
30
7
2
38
3
4
55
5
19
8
45
54
52
5
53
31
9
45
23
24
17
43
52
12
21
CLB-603 INFEED PUMP ASSY EXPLODED VIEW
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
50
ITEM PART NO. DESCRIPTION QTY
1 8.715-387.0 Pump, Amt 1/2 HP, 115/230V
1 PH, 2852-95 Curve C 1
2 8.706-461.0 Nipple, 1-1/4" Close, PVC 80 1
3 8.706-415.0 Bushing, 1.5" MT x 1.25" FT,
PVC 80 1
4 8.706-372.0 Elbow, 1-1/2" S x T, PVC 80
90° 5
5 8.706-374.0 Elbow, 1-1/2" S x S, PVC 80
90° 3
6 8.706-428.0 Tee, 1-1/2" S x S x T 1
7 8.718-659.0 Bolt, 3/8 "x 1-1/4 NCH HSS 2
8 8.749-845.0 Valve, 3 Way Diverter
w/Actuator 1
9 8.706-367.0 Pipe, 1.5" PVC 80 19.5 in
10 8.706-405.0 Bushing, 1-1/4" x 1" MT x FT,
PVC 80 1
11 8.706-439.0 Nipple, 1" PVC 80, Close 3
12 8.706-429.0 Tee, 1" FT x FT x FT, PVC 80 2
13 8.706-928.0 Bushing, 1" x 1/2"
Black Poly Reducer 2
14 8.706-876.0 Nipple, 1/2" JIC x 1/2" MPT SS 2
15 8.707-005.0 Swivel, 1/2" JIC FEM
Push-on SS 2
16 9.802-259.0 Hose, 1/2" Push-on 24 in
17 8.706-394.0 Plug 1-1/2" PVC 80 1
18 8.756-649.0 Valve, Ball, 1", Pneu Act,
No Sol 1
19 8.706-367.0 Pipe 1.5 PVC 80 3.5 in
20 9.802-699.0 Screw 10/32" x 3/4" Slot Pan 4
21 9.802-696.0 Nut 10/32" Keps SS 4
22 8.902-236.0 Cone, 3/16 w/Holes 1
23 8.900-458.0 Label Inlet 1
24 9.802-799.0 Screw, #14 x 1" Tek Head 1
25 8.706-448.0 Adapter, 1.5 x 1.5 Ft x Slip 1
26 8.706-404.0 Bushing, 11/2" x 1" MT x FT,
PVC 80 1
27 9.802-788.0 Nut 3/8 " Whiz Loc SS 6
28 8.749-860.0 Check Valve
(w/optional pH Pump) 1
29 8.749-857.0 Tubing PE (option) Black 1/4" 7 ft.
30 9.802-808.0 Washer 3/8" Flat SS 2
31 8.706-379.0 Elbow, 1-1/2" SLIP x SLIP,
CLB-603 INFEED PUMP ASSY EXPLODED VIEW PARTS LIST
PVC 80, 45° 3
ITEM PART NO. DESCRIPTION QTY
32 8.707-344.0 Valve, PVC 1.5" SLIP x SLIP,
Gate 1
33 8.706-469.0 Union, 1-1/2" SLIP x SLIP,
PVC 80 3
34 8.706-468.0 Nipple 1.5" x 3" PVC 80 2
35 8.706-424.0 Nipple, 1.5" x Close, PVC 80 2
36 8.706-490.0 Bulkhead, 1-1/2" Polypro 2
37 8.711-815.0 Hose, 1-1/2" Gray Conduit 22 in
38 8.706-426.0 Tee, 1.5" S x S x S, PVC 80 3
39 9.802-517.0 Connector 1/2" LT 90° Black 1
40 8.712-136.0 Gauge, Flowmeter 1.5 1
41 8.706-360.0 Pipe 1.5 PVC Clear 8.5 in
42 8.913-161.0 Pump Plate 1
43 8.706-421.0 Hanger, 1-1/2" Pipe 5
44 8.707-343.0 Valve, 1" Gate, NPT 1
45 8.900-474.0 Label, Flow Arrow 3
46 8.711-815.0 Hose, 1-1/2" Gray, 32 in
47 8.706-367.0 Pipe, 1.5" PVC, (1.5" x 8") 2
48 8.706-455.0 Nipple 1" x 2" PVC 80 2
49 8.707-298.0 Valve, Ball Check 1/2" PVC 1
50 8.706-467.0 Nipple, 1/2" PVC 80, Close 1
51 8.711-815.0 Hose, 1-1/2" Gray Conduit 30 in
52 8.706-367.0 Pipe, 1.5" PVC 80 (1"x 2.5") 8
53 8.706-367.0 Pipe, 1.5" PVC 80 8 in
54 8.711-815.0 Hose 1 -1/2 Gray Conduit 6 in
55 8.706-367.0 Pipe, 1.5" PVC 80 4.5 in
56 8.711-815.0 Hose, 1-1/2" Gray, Conduit 32 in
57 8.711-815.0 Hose, 1-1/2" Gray, Conduit 108 in
background
8.914-458.0-G • Water Maze CLB-603
51
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-17
30
7
37
CLB-603 TRANSFER/OZONE PUMP ASSY EXPLODED VIEW
Transfer
Pump
To Ozone
Generator
Mazzi
Injector
Assy
Ozone
Pump
To Water
Panel
To Manifold
Assy.
38
21
39
41
40
54
46
45
42
45
46
39
1
45
43
44
3
37
7
38
21
58
To Ozone
Generator
59
31
28
52
49
25
26
8
25
38
24
35
38
23
22
4
5
50
32
6
7
33
6
20
9
56
11
10
12
13
12
56
17
36
16
15
14
51
19
53
28
23
22
38
24
18
34
56
29
47
47
57
55
57
2
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
52
ITEM PART NO. DESCRIPTION QTY
1 8.755-986.0 PUMP, SCOT 11, 3/4HP 230V
1PH 4.88DIA 1
8.715-402.0 Pump, Scot 2 HP, 208/230 Volt
1 PH (Optional) 1
2 8.726-024.0 Pump, 3/4 HP, Wet End 1
3 8.726-026.0 Motor, 3/4 HP, 230V 1
4 8.706-378.0 Elbow, 1" SLIP x FIPT,
PVC 80, 90° 1
5 8.706-439.0 Nipple, 1", PVC 80 Close 1
6 8.706-373.0 Elbow, 1" S x S, PVC 80, 90° 2
7 8.707-300.0 Valve, 1" PVC Ball Check 2
8 8.706-367.0 Pipe, 1-1/2" PVC 80 4.5 in
9 8.706-430.0 Tee, 1" S x S x S, PVC 80 1
10 8.706-447.0 Adapter, 1" x 3/4" S x FIPT
PVC 80 1
11 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 1
12 8.706-444.0 Adapter, Female, 1" SLIP x FT
PVC 80 2
13 8.709-431.0 Injector, Ozone w/o Chk Valve 1
14 8.706-370.0 Elbow, 1/2" FIPT x FIPT,
PVC 80, 90° 1
15 8.706-587.0 Nipple, 1/2" x 1/4" 1
16 8.707-321.0 Valve, Ozone Meter, 1/4"
5310.002 Plastic 1
17 8.707-359.0 Valve, 1" S 80 PVC, S x S 1
18 8.706-374.0 Elbow, 1-1/2" S x S, PVC 80,
90° 1
19 8.706-423.0 Hanger, Pipe, 1" Click #32 1
20 8.706-366.0 Pipe, 1" PVC 80 7.5 in
21 8.706-409.0 Adapter, 1" MT x SLIP, PVC 80 1
22 8.706-461.0 Nipple, 1-1/4" x Close PVC 80 1
8.706-424.0 Nipple, 1.5" x Close PVC 80
(2 HP Option) 1
23 8.706-470.0 Union, 1-1/2" Slip x Thread
PVC 80 1
24 8.706-426.0 Tee, 1.5" S x S x S, PVC 80 1
25 8.706-379.0 Elbow, 1-1/2" SLIP x SLIP
PVC 80, 45° 2
CLB-603 TRANSFER/OZONE PUMP ASSY EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
26 8.706-367.0 Pipe, 1.5" PVC 26 in
27 8.905-717.0 Ozone Generator 230V 1 PH 1
28 8.900-474.0 Label, Flow Arrow 2
29 8.707-355.0 Ozone Check Valve 1
30 8.900-210.0 Label, Warning 1
31 8.901-115.0 Label, Air Valves Pressure
Regulator 1
32 8.706-366.0 Pipe, 1" PVC 80 7 in
33 8.706-366.0 Pipe, 1" PVC 80 4.5 in
34 8.706-367.0 Pipe, 1.5" PVC 80 4 in
35 8.706-360.0 Pipe, 1.5" PVC 80 Clear 8.5 in
36 8.706-588.0 Connector, 3/8" x 1/4"
Male Elbow 1
37 8.711-812.0 Hose 1" Gray Conduit 10 in
38 8.706-367.0 Pipe, 1.5" PVC 80
1-1/2 x 2-1/2 Spacer 3
39 8.913-161.0 Pump Plate 2
40 8.718-619.0 Bolt 5/16" x 3/4" NCGR, SS 4
41 9.802-805.0 5/16" Washer Flat SS 4
42 8.718-887.0 5/16" Whiz Loc 4
43 8.718-659.0 Bolt 3/8" x 1-1/4" NCHHSS 2
44 9.802-808.0 Washer 3/8" SS 2
45 9.802-788.0 Nut 3/8" Whiz Loc SS 10
46 9.802-517.0 Connector 1/2" LT 90° Black 2
47 9.802-799.0 Screw #14 x 1" Tek Head 2
48 8.706-424.0 Nipple, 1-1/2" Close, PVC 80
49 8.906-421.0 Hanger 1-1/2" Pipe 1
50 8.706-398.0 Bushing 1" FIPT x 1-1/2"
PVC 80 1
51 8.706-366.0 Pipe 1" PVC 80 13 in
52 8.900-458.0 Label Inlet 1
53 8.900-459.0 Label Outlet 1
54 9.802-794.0 Nut Cage 1/4" x 12 Ga 1
55 8.706-415.0 Bushing 1.5 MT x 1.25 PVC 80
(Not used with 2 HP Option) 1
56 8.706-366.0 Pipe 1" PVC 80 Spacer
1" x 2" 1
57 8.750-270.0 Fitting, Compression,
1-1/2" Slip 2
58 8.706-405.0 Bushing, 1-1/4" MT x 1" FT
PVC, Sch 80 (2 HP Option) 1
59 8.901-116.0 Label, Air Stone Diffuser
Pressure Regulator 1
background
8.914-458.0-G • Water Maze CLB-603
53
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-26
Junction Box
Assembly
(Reverse View)
See
CLB Air
Components
Exploded
View
44
27
46
36
36
40
37
39
38
39
40
37
18
21
33
26
31
29
30
35
30
29
7
41
59
61
60
59
21
8
9
10
12
34
54
4
3
16
45
5
6
55
56
24
11
48
27
14
17
14
14
43
14
13
15
57
32
To
Manifold
Assembly
47
33
27
52
53
52
50
51
50
20
19
20
23
21
18
25
2
42
1
42
27
28
27
21
22
17
14
26
27
27
58
49
CLB-603 DRAIN SURGE TANK EXPLODED VIEW
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
54
CLB-603 DRAIN SURGE TANK EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.756-648.0 Valve, Ball, 1-1/2", Pneu Act,
No Sol 1
2 8.706-451.0 Adapter, 2" Slip x MT, PVC 80 1
3 8.716-547.0 Connector, 1/2" Straight 3
4 8.718-760.0 Screw, 10/32 x 5/8", Phil, SS 8
5 8.932-941.0 Label, WaterMaze, CLB-603
# 4, Junction Box 1
6 8.724-756.0 Label, WaterMaze, CLB-603
# 3, Junction Box 1
7 8.707-349.0 Valve, 2" Single Union Ball 1
8 8.706-466.0 Nipple, 2" Close, PVC 80 2
9 8.706-436.0 Tee, 2", FT x FT x FT, PVC 80 1
10 8.706-479.0 Bulkhead, 2" NPT, Polypro 1
11 9.802-483.0 Cover, Metal, 2" x 4",
Weather Proof 4
12 8.706-418.0 Bushing Reducer, 2 x 1,
PVC 80 MPT x FPT 1
13 8.706-409.0 Adapter, 1" MT x SLIP,
PVC 80 1
14 8.706-366.0 Pipe, 1" PVC 80,
1" x 2" Spacer 5
15 8.706-371.0 Elbow, 1" SxS, PVC 80 45° 1
16 8.724-755.0 Label, WaterMaze, CLB-603, #2,
Junction Box 1
17 8.707-359.0 Valve, 1" PVC S x S 2
18 8.706-846.0 Tee, 3/4" FIPT, Brass 2
19 8.706-430.0 Tee, 1" S x S, PVC 80 1
20 8.706-447.0 Adapter, 1" x 3/4" S x FIPT,
PVC 80 2
21 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 4
22 8.706-447.0 Adapter, 1", 3/4" S x FIPT
PVC 80 1
23 8.706-800.0 Nipple, 3/4" Hex, Brass 1
24 8.724-754.0 Label, WaterMaze, CLB-603, #1,
Junction Box 1
25 8.706-869.0 Plug, 3/4" Hex Head 1
26 8.706-378.0 Elbow, 1" SLIP x FIPT, PVC 80
90° 2
27 9.802-152.0 Swivel, 3/4" SAE Fem.
Push-on 8
28 9.802-261.0 Hose, 3/4", Push-on 36 in
29 8.706-439.0 Nipple, 1" PVC 80, Close 2
30 8.706-484.0 Bulkhead, 1" Polypro 1
31 8.706-366.0 Pipe, 1", PVC 80 12 in
32 8.706-823.0 Elbow, 3/4" Female 90° 1
ITEM PART NO. DESCRIPTION QTY
33 9.803-557.0 Elbow, 3/4" SAE x 3/4"
90° Brass 2
34 8.940-186.0 Label, Float, Switch,
Junction Box 1
35 9.802-261.0 Hose, 3/4" Push-on 30 in
36 8.719-176.0 Tank, 10 Gal Pre-pressurized,
Blue 2
37 8.719-021.0 Washer, 1/2, Lock 5
38 8.913-160.0 Bracket, Pressure Tank 1
39 8.718-997.0 Washer, 5/8, Flat 5
40 8.718-893.0 Nut, 1/2", SS, 304, Hex, NC 5
41 8.706-476.0 Union, 2", FSX FT, PVC 80 1
42 8.706-367.0
Pipe, 1.5", PVC 1.5 x 2-3/4
2
43 8.706-597.0 Union, 1", S x S, PVC 80 1
44 8.706-800.0 Nipple, 3/4", Hex, Brass 2
45 8.716-324.0 Box, Junction, 4 Hole, 1/2" 3
46 8.913-156.0 Assy, Bracket, Pressure Tank,
MS, CLB-603 1
47 9.802-261.0 Hose, 3/4", Push-on 24 in
48 9.802-261.0 Hose, 3/4", Push-on 53 in
49 9.802-696.0 Nut, 10/32", ST, Keps 8
50 8.706-369.0 Nipple, 3/4" PVC 80, Close 2
51 8.707-339.0 Valve, Ball, 3/4" PVC 1
52 8.706-412.0 Bushing, 1 x 3/4" MT x FT, PVC 2
53 8.716-700.0 Solenoid Valve, 120V HIT 1
54 8.913-162.0 Bracket, Electrical 1
55 9.802-514.0 Strain Relief, LQ Tite, 1/2" 10
56 8.716-323.0 Box, Junction 5 Hole, 1/2" 1
57 9.802-099.0 Washer, Snubbing (shims) 2
58 8.900-462.0 Label, Drain 1
59 8.706-413.0 Bushing, 2' X 1 1/2' Slip,
PVC 80 2
60 8.706-958.0 Hose Barb, 1/4" Barb x 1/4"
MPT, 90 DGR 1
61 8.756-650.0 Muffl er, Exhaust, 1/4"
NPT, Brass 1
background
8.914-458.0-G • Water Maze CLB-603
55
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
CLB-603 AIR COMPONENTS EXPLODED VIEW
89144580-46
1
2
2
2
20
Gemu
Air
Solenoid
Valve
Assy.
Air Valves
Pressure
Regultor
Assy.
Air Stone
Diffuser
Pressure
Regulator
Assy.
Gemu
Air
Solenoid
Valve
Assy.
3
7
12
24
1
13
25
25
25
21
19
14
5
18
14
5
10
6
7
8
11
8
9
4
GF Air
Solenoid
Valve Assy.
Air Solenoid
Bracket
Assy.
24
23
2
1
2
1
6
7
11
8
9
8
10
1
2
22
10
20
17
16
1
1
15
23
3
2
2
13
22
25
4
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
56
CLB-603 AIR COMPONENTS PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.706-958.0 Hose Barb 1/4" Barb x 1/4"
Pipe 90° 7
2 6.390.126.0 Clamp Hose 9
3 8.756-654.0 Valve, Solenoid, Air,
120V, SV16 2
4 9.802-799.0 Screw 1/4" x 1" TEK BLK 4
5 8.707-016.0 Elbow 1/4" NPT x 3/8"
Push-on 2
6 8.707-331.0 Regulator, Air w/Fitter
1/4" Gauge 2
7 8.706-777.0 Nipple, 1/4" Close 3
8 8.706-915.0 Bushing, 1/2"x 1/4" Brass 4
9 8.707-177.0 Nipple 1/4" Male Air 2
10 8.706-854.0 Tee 1/4" Branch Male 3
11 9.802-961.0 Hose Connection Bracket 2
12 8.706-858.0 Tee 1/4" Streel 1
13 8.706-941.0
Hose Barb, 1/4" MT x 1/4"
Hose
2
14 8.709-069.0 Clamp Screw #4 2
15 8.913-164.0 Bracket, Air Solenoid 1
16 8.718-755.0 Screw, 8/32" X 1-1/2",
SS PHIL PH 2
17 8.718-868.0 Nut, 8-32 ESNA, SS 2
18 8.711-733.0 Tubing 3/8" Vinyl 120 in
19 8.711-733.0 Tubing 3/8" Vinyl 12 in
20 9.802-254.0 Hose 1/4" Push-on 9 in
21 9.802-254.0 Hose 1/4" Push-on 12 in
22 9.802-254.0 Hose 1/4" Push-on 19 in
23 9.802-254.0 Hose 1/4" Push-on 31 in
24 9.802-254.0 Hose 1/4" Push-on 34 in
25 8.756-650.0 Muffl er, Exhaust, 1/4"
NPT, Brass 8
background
8.914-458.0-G • Water Maze CLB-603
57
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-11
To Water
Panel
Assy.
To Transfer
Pump
Assy.
20
21
19
7
5
7
CLB-603 MANIFOLD ASSEMBLY EXPLODED VIEW
To Surge
Tank
Manifold
Mounting
Bracket
To Main
Drain
Assembly
12
13
10
11
9 8
14
16
12
15
12
7
8
7
6
7
5
3
17
18
2
4
1
6
6
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
58
CLB 603 MANIFOLD ASSEMBLY EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.716-154.0 Switch, Pres Sq. D N/C 1
2 8.706-858.0 Tee, 1/4" Street 1
3 8.712-154.0 Gauge, Pressure 0-100 1
4 8.706-923.0 Bushing, 3/4" x 1/4" Pipe 1
5 8.706-447.0 Adapter, 1", 3/4" S x FIPT,
PVC 80 2
6 8.706-430.0 Tee, 1" S x S, PVC 80 3
7 8.706-366.0 Pipe, 1" PVC 80 (1"x 2") 6
8 8.706-373.0 Elbow, 1" S x S, PVC 80, 90° 2
9 8.706-409.0 Adapter, 1" MT x SLIP, PVC 80 1
10 8.716.-700.0 Solenoid, Valve 120V 1
ITEM PART NO. DESCRIPTION QTY
11 8.706-412.0 Bushing, 1" x 3/4" MT x FT,
PVC 80 1
12 9.803-557.0 Elbow, 3/4" SAE x 3/4"
90° Brass 3
13 8.706-597.0 Union, 1", S x S, PVC 80 1
14 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 1
15 8.706-800.0 Nipple, 3/4" HEX, Brass 1
16 8.706-852.0 Cross, 3/4" Female Pipe 1
17 8.706-777.0 Nipple, 1/4" Brass 1
18 8.716-547.0 Connector, 1/2" Straight 1
19 8.706-422.0 Hanger Pipe, 1 1/4" 2
20 9.802-699.0 Screw 10-32" Slot Pan 2
21 9.802-696.0 Nut 10/32" Keps 2
background
8.914-458.0-G • Water Maze CLB-603
59
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-18
11
25
CLB-603 WATER PANEL EXPLODED VIEW
To Ozone
Pump
Assy.
To
Manifold
Assy.
Ozone
Generator
Water
Panel
Assy
3
10
14
17
13
5
2
2
24
1
10
17
4
16
4
15
13
4
13
17
18
20
12
8
7
6
19
9
10
22
23
12
21
12
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
60
CLB-603 WATER PANEL EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.716-700.0 Solenoid Valve 120V,
HIT 310-100-1 1
2 8.706-412.0 Bushing, 1" x 3/4" MT x FT,
PVC 80 2
3 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 1
4 8.706-968.0 Garden Hose Fitting 3
5 8.706-881.0 Nipple 3/4" pipe 1/2 Pipe 1
6 8.706-597.0 Union, 1" S x S, PVC 80 1
7 8.706-366.0 Pipe, 1" PVC 80 1" x 2" Spacer 1
8 8.706-409.0 Adapter, 1" MT x SLIP,
PVC 80 1
9 9.802-132.0 Elbow, 3/4" JIC x 1/2", 90° 2
10 9.802-152.0 Swivel, 3/4" SAE Fem,
Push-on 6
11 9.802-261.0 Hose, 3/4" Push-on 43 in
ITEM PART NO. DESCRIPTION QTY
12 8.707-000.0 Connector, 1/2" Anchor 3
13 8.706-790.0 Nipple, 1/2" Close 4
14 9.802-146.0 Swivel, 1/2" MP x 3/4" GHF
w/Strainer 1
15 8.706-801.0 Nipple, 1" Close, Brass 1
16 8.707-233.0 Valve, 1" Ball, Brass 1
17 8.707-211.0 Valve, 1/2" 8201 Brass Ball,
400 PSI 3
18 8.913-153.0 Water Panel 1
19 9.802-794.0 Nut Cage, 1/4" x 16 GA 4
20 9.802-765.0 Screw, 1/4-20 X 1/2",
BH Black 4
21 8.901-227.0 Label, Water Maze 1
22 9.802-261.0 Hose, 3/4", Push-on 20 in
23 9.802-261.0 Hose, 3/4", Push-on 30 in
24 8.706-926.0 Bushing, 1" x 1/2", Pipe, Brass 1
25 8.711-812.0 Hose 1" Gray Conduit 26 in
background
8.914-458.0-G • Water Maze CLB-603
61
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-23
41
40
10
36
55
48
56
CLB-603 CONTROL PANEL EXPLODED VIEW
T3 Ozone
Timer
T4
Microbe
Nutrient
Timer
T1 Infeed
Pump Timer
T2 Purge
Timer
pH Controller Assy
(Optional)
Pump
Contactor Detail
37
41
55
38
49
Sensor
32
32
39
42
14
33
47
46
34
30
35
31
31
53 30
54
28
45
45
26
45
11
18
29
15
16
17
20
7
21
22
24
25
12
45
8
19
23
1
1
1
1
6
2
3
5 4
45
51
43
40
55
56
58
50
57
13
20
52
59
27
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
62
ITEM PART NO. DESCRIPTION QTY
1 9.802-451.0 Switch, Rocker, Carling
w/Green Lens 4
2 9.802-283.0 Hour Meter 1
3 9.802-455.0 Light, Indicator, Green 125V 1
4 8.716-091.0 Switch, Momentary Push, 100S
Use w/2-3020 1
5 8.716-409.0 Light, Blue 125V 1
6 8.716-533.0 Clamp, Tie Wrap, Adhesive 21
7 8.724-264.0 Contactor, 120V 4
8 9.803-977.0 Fuse, 2.5 Amp, FNM 2-1/2 1
9 8.901-229.0 Label, Contactor 1
10 8.716-898.0 Transformer, .150KVA,
230/115V w/Fuse Block 1
11 8.716-253.0 Timer, 24 Hour Pin, 120V 20A 4
12 9.800-040.0 Label, Ground 1
13 8.716-460.0 Terminal, Grounding Lug,
LAMA6-14-Q 1
14 8.716-120.0 Block, Power Distr Adder
GO63130 w/o WLL 1
8.716-121.0 Block, Power Distr 1 Pol
GO63131 1
15 9.802-467.0 Base, Relay, SH2B-05, IDEC 1
16 9.802-468.0 Relay, 120V, RH2B-UL-AC120 1
17 8.751-306.0 Timer, Multi-Function,
24V-120/240V 1
18 9.802-457.0 Din Rail, 35mm 15.5 in.
19 8.716-402.0 Bridge, Entrelec 16897307 21
20 9.804-595.0 End Bracket, Entrelec
103-002-26 2
21 8.716-396.0 Terminal Block, Entrelec
115-116-07 M4/6 33
22 8.716-399.0 End Cover, Entrelec, Gray
11836816 P-On 9
23 8.716-399.0 End Cover, Entrelec
11836816 P-ON 1
24 8.716-398.0 Terminal Block, Blue, Entrelec
125116-01 8
25 9.804-609.0 Marker, Blank - 6mm,
23300001, NK,
RCG10 100/SH 0.92
26 8.753-351.0 Channel, 1", Gray w/Cover 7 in
27 8.718-568.0 Washer, 1/4" SS
Sealing Rubber 2
28 9.802-457.0 Din Rail, 35mm 9 in
29 9.802-759.0 Screw, 10/32" x 1/2 BHSOC
Blk 4
CLB-603 CONTROL PANEL EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
30 9.802-514.0 Strain Relief, STRT, LQ Tite
3231 Small 28
31 8.716-547.0 Connector, 1/2" Straight, BLK 7
32 9.802-788.0 Nut, 3/56" SS Whiz Loc 12
33 8.716-280.0 Box, Plastic, 18 x 16 x 9.25
w/Hinged Lid 1
34 8.718-621.0 Bolt, 5/16" x 14" NC, HH, SS 4
35 9.802-105.0 Plug, 7/8", Hole 2
36 8.918-076.0 Wlmt, Electrical Standoff CLP 1
37 8.716-989.0 pH Controller w/Sensor
(Option) 1
38 8.913-143.0 Bracket, pH Controller (Option) 1
39 8.913-152.0 Bracket, Microbe/Nutrient Pump 1
40 9.802-765.0 Screw, 1/4" x 1/2" BH SOC CS 4
41 9.802-793.0 Nut, Cage, 1/4" x 16 Ga 8
42 8.749-856.0 Pump, Peristaltic 2
43 8.901-228.0 Label, Water Maze, CLB-603
Control Panel 1
44 8.901-226.0 Label, Electrical Timers 1
45 8.718-936.0 Screw, # 8 1/2, Phillips 25
46 9.802-805.0 Washer, 5/16" Flat, SAE, SS 4
47 8.913-149.0 Stand Off Plate 1
48 8.749-855.0 Pump, Peristaltic
8-45 gpd (Option) 1
49 8.716-905.0 Sensor, pH (Option) 1
50 8.901-223.0
Label, WaterMaze Nutrient Pump
1
51 9.803-674.0 Screw, 8/32 x 2" 1
52 9.802-785.0 Nut, 8/32 Keps 5
53 9.802-244.0 Conduit, WTR, Tite, Flex 57 in
54 9.802-244.0 Conduit, WTR, Tite, Flex 57 in
55 8.749-857.0 Tubing, Pe Black 1/4" x 4 ft 2
(Option 1/4" x 5 ft) 1
56 8.718-941.0 Screw, 10-16 x 5/8 TEK4
(Option) 2
57 8.901-222.0 Label, Watermaze,
Microbe Pump 1
58 8.900-467.0 Label PH Pump (Option) 1
59 8.718-603.0 Bolt, 1/4" x 3/4" SS 2
Not Shown
background
8.914-458.0-G • Water Maze CLB-603
63
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-25
CLB-603 DIMENSION LOCATIONS OF TANK CONNECTIONS
1-1/2"
Infeed
Connector
3" Outlet
Connector
1-1/2" Oil
Skimmer
Connector
1-1/2"
Recirculation
Connection
1" Purge
Flush
Connection
Plan View of Tank
8" from
Tank Rim
Oil
Skimmer
Connection
17"
from
Tank
Rim
70" to
Tank
Rim
65" to
Tank
Rim
65" to
Tank Rim
1-1/2" Infeed
Connection
1" Purge
Flush
Connection
1-1/2"
Recirculation
Connection
2-1/2"
9"
12"
5"
Air Stone
Air Line
Microbe
Injection
Nutrient
Injection
Front of
Machine
2" From
Tank Rim
See
Digester
Assy. for Air
Stone Assy.
Air Stone
Air Line
Air Stone
Air Stone
Bracket
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
64
89144580-13
OZONE GENERATOR
DISCONNECT F
R
OM ELECTRICAL
SUPP
L
Y BEFORE SE
R
VICING.
DESCONECTE LA CORRIENTE ELECTRICA
ANTES DE D
AR SE
R
VICI
O
.
COUPER
L
’ALIMEN
TA
TION ÉLECTRI
Q
UE
AV
ANT DE
F
AIRE UNE RÉ
P
AR
A
TION.
DISCONNECT F
R
OM ELECTRICAL
SUPP
L
Y BEFORE SE
RVICING.
DESCONECTE LA CORRIENTE ELECTRICA
ANTES DE D
AR SE
R
VICI
O
.
COUPER
L
’ALIMEN
TA
TION ÉLECTRI
Q
UE
AV
ANT DE
F
AIRE UNE RÉP
AR
A
TION.
INDICATOR
L
IGHT OPERAT
I
O
N
A b
right contin
uous light indicates UV
light or ballast de
f
ecti
v
e
.
Una luz luminosa indica que la luz ult
r
a-
violeta o t
r
ans
f
o
r
mador está de
f
ectuos
o
.
Une lumière claire indique que la lumière
ult
r
aviolette ou le t
r
ans
f
o
r
mateur est
f
ectueux.
OPER
ACION DE LA LUZ
INDICADORA
OPÉR
ATION DE LE LAMPE
INDIC
A
TEUR
HO
T!
CALIENTE!
C
HA
UD!
CA
UTION
PRECA
UCION
A
TTENTION
8.900-455.0
!
W
ARNING!
AT
ENC
IO
N
!
/
A
TT
ENT
I
ON
!
!
ITEM PART NO. DESCRIPTION QTY
1 8.913-357.0 Ozone Box, Back, 400 1
2 8.913-360.0 Ozone Box, Front 400 1
3 9.802-455.0 Light, Indicator, Green 4
4 9.802-523.0 Locknut, 3/4" Conduit 4
5 8.716-583.0 Connector, Aluminum Cord
SCH1037 4
6 8.707-355.0 Ozone Check Valve 1
7 8.716-600.0 Lamp, Ozone Replacement 4
8 8.900-455.0 Label, Ozone Generator 1
9 9.802-695.0 Nut, 10/32", NF ST ST KEP 4
10 8.706-570.0 Locknut, 3/8" Nylon 2
11 8.706-585.0 Connector, 3/8" x 3/8",
Male Elbow, Kynar 2
12 8.706-594.0 Tee, 3/8" Kynar 1
13 8.706-733.0 Bushing, 1/2" Snap 1
14 8.711-733.0 Tubing, 3/8" x 1/2",
Black Vinyl 6 ft.
ITEM PART NO. DESCRIPTION QTY
15 9.802-423.0 Cord, Service, SEO, 16/3 8 ft.
16 9.802-453.0 Switch, Curvette, 120V & 220V 1
17 9.802-515.0 Strain Relief, 1/2" NPT
Ozone Gen 1
18 8.706-545.0 Cushion, 1/2", 13-3/4" x 5-3/4",
Rubber 1
19 8.913-358.0 Ozone Box, Top 1
20 8.913-359.0 Ozone Box, Bottom 1
21 8.716-590.0 Ballast, 220V,
Ozone Generator
4
22 9.804-566.0 Screw, 10/32" x 1/2" Slot Pan,
MS ZN 12
23 8.718-968.0 Washer, 10 x SAE ZN 12
24 9.802-798.0 Screw, #10 x 1/2" Tek
Hex Head 8
OZONE GENERATOR EXPLODED VIEW
OZONE GENERATOR EXPLODED VIEW PARTS LIST
Ballast
Ozone Lamp
Prongs
On/Off
Switch
Ozone
Lamp
21
9
23
10
1
4
11
19
12
11
17
13
14
6
16
3
22
8
2
20
18
24
7
15
5
background
8.914-458.0-G • Water Maze CLB-603
65
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-4
Purge
Valve
Assy.
Power In
Customer
Connection
120V 1PH
10"
From
Tank Top
For Detail
See Optional
Oil Skimmer/
Sludge Tub
Illus.
For Detail
See Optional
Oil Skimmer/
Sludge Tub
Illus.
14" From
Tank Top
2
3
30
11
14
Field
Installed
7
12
55
10
63,64
61,62
9
19
20
16
21
17
18
33
39
56
48
51
49
50
6
2
3
4
5
43
2
66
8
32
47
31
47
34
35
36
37
38
28
29
26
23
22
24
65
38
23
37
29
28
48
50
49
47
40
41
67
68
67
44
42
15
15
13
46
45
28
27
25
See
Digester
Assy. for Air
Stone Assy.
Air Stone
Air Line
Air Stone
Air Stone
Bracket
17
CLB-30 AUXILIARY DIGESTER ASSEMBLY EXPLODED VIEW
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
66
ITEM PART NO. DESCRIPTION QTY
1 8.719-177.0 Tank, 600 Gal, Clarifi er, w/Lid 1
2 8.706-483.0 Bulkhead, 3" FT x FT, Polypro 2
3 8.706-454.0 Adapter, 3" SLIP x MT, PVC 40 2
4 8.706-368.0 Pipe, 3" PVC 40 24 in.
5 8.706-385.0 Elbow, 3" SLIP x SLIP, PVC 40 1
6 8.706-368.0 Pipe, 3" PVC 40 36 in
7 8.706-368.0 Pipe, 3" PVC 40 6 in
8 8.913-095.0 Assy, Tank Stand 1
9 8.706-648.0 Handle, Sandpot Lid 2
10 8.706-568.0 Handle, Rubber T, w/Keeper 3
11 8.902-236.0 Cone, 3/16" w/Holes 1
12 8.707-435.0 Bag, Pre-Sewn, Eofi ll 6
8.706-676.0 Plastic, Eofi ll, Bio-System 36 lb
13 8.706-476.0 Union, 2" FS x FT, PVC 80 1
(option)
14 8.706-437.0 Tee, 3" Slip 1
15 8.706-367.0 PIPE, 1.5", PVC 80, /FT
1.5 x 2-3/4 2
16 8.913-157.0 Bracket, Air Stick 1
17 8.706-409.0 Adapter, 1" MT x SLIP, PVC 80 2
18 8.706-366.0 Pipe, 1", PVC 80 1" x 48", 2
19 9.802-721.0 Bolt, 3/8" x 1", HH, SS 10
20 9.802-808.0 Washer, 3/8, SAE SS 10
21 9.802-788.0 Nut, 3/8", Whiz Loc, SS 10
22 8.706-479.0 Bulkhead, 2" NPT, Polypro 1
23 8.706-466.0 Nipple, 2" Close, PVC 80 2
24 8.706-436.0 Tee, 2" FT x FT x FT, PVC 80 1
25 8.706-418.0
Bushing, Reducer, 2 x 1, PVC-80
1
26 8.706-409.0 Adapter, 1" MT x SLIP, PVC 80 1
27 8.706-371.0 Elbow, 1" S x S, PVC 80, 45° 1
28 8.706-366.0 Pipe, 1" PVC 80, 1" x 2" 4
29 8.707-359.0 Valve, 1" S 80 PVC S x S
Molded in Place Ball 2
30 8.706-368.0 Pipe, 3" PVC 40 22 in
(Field Installed)
31 8.706-430.0 Tee, 1" S x S, PVC 80 1
32 8.706-397.0 Plug, 3/4" MT, Sch 80 PVC 1
33 9.800-034.0 Label, Clear Lexan 1
34 8.706-800.0 Nipple, 3/4", Hex, Brass 1
35 8.706-846.0 Tee, 3/4", Female Pipe Brass 1
36 8.706-869.0 Plug, 3/4", Hex, Head 1
37 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 2
38 9.802-152.0 Swivel, 3/4" SAE Fem, Push-on 2
39 9.800-013.0 Label, ASSLD,
USA intended for indoor use 1
40 8.707-349.0 Valve, 2", Single Union Ball 1
41 8.706-451.0 Adapter, 2" Slip x MT, PVC 80
(option) 1
ITEM PART NO. DESCRIPTION QTY
42 8.756-648.0 Valve, Ball, 1-1/2", PNEU ACT,
NO SOL 1
43 8.706-490.0 Bulkhead, 1-1/2" Polypro 1
44 8.706-958.0 Hose Barb, 1/4" Barb x 1/4" Pipe,
90° (option) 1
45 6.390-126.0 Clamp, Hose, .46-.54 ST
(option) 2
46 9.802-254.0 Hose, 1/4" (option) 15 ft
47 8.706-447.0 Adapter, 1", 3/4" S x FIPT,
PVC 80 3
48 8.706-378.0 Elbow, 1" SLIP x FIPT,
PVC 80, 90° 2
49 8.706-439.0 Nipple, 1", PVC 80, Close 2
50 8.706-484.0 Bulkhead, 1" Polypro 1
51 8.706-366.0 Pipe, 1", PVC 80 12 in
52 9.802-486.0 Wire-nut, Orange
(In Conduit Box) 4
53 8.750-743.0 Bulkhead, 1/2", NPT Polypro 2
54 9.802-517.0 Connector, 1/2", 90° 1
55 8.900-841.0 Label, Water Maze Logo 1
56 ETL Label 1
57 8.716-377.0 Terminal Ring Tongue 1
58 9.802-696.0 Nut, 10/32" Kep 3
59 8.718-600.0 Bolt, 1/4"-20 x 1-1/4 Hex, SS 1
60 9.802-763.0 Screw, 10/32" x 1 1/4", Slot
(Ground for Junction Box) 1
61 9.802-699.0 Screw, 10/32" 8
62 9.802-696.0 Nut, 10/32" 8
63 9.802-747.0 Screw, 6/32" x 5/16" Round 12
64 8.718-854.0 Nut, 6/32", Keps 12
65 9.802-261.0 Hose, 3/4", Push-on 35 in
66 8.706-394.0 Plug, 11/2", PVC 80 1
67 8.706-413.0 Bushing, 2' X 1 1/2'
Slip, PVC 80 2
68 8.756-650.0 Muffl er, Exhaust, 1/4"
NPT, Brass 1
Not Shown
CLB-30 AUXILIARY DIGESTER ASSEMBLY PARTS LIST
background
8.914-458.0-G • Water Maze CLB-603
67
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-5
Air Stone
Air Line
Air Stick
Float
Switch
CLB-30 AUXILIARY DIGESTER ASSEMBLY EXPLODED VIEW
Connected to
Air Stone Pressure
Regulator
Air
Stone
Assy
10
20
6
7
8
9
3
12
13
9"
11
6
14"
Air Stone
Air Line
Air Stone
Air Stone
Bracket
1
2
2
15
16
17
18
3
14
5
5
19
14
4
11
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
68
ITEM PART NO. DESCRIPTION QTY
1 8.711-733.0 Tubing, 3/8 x 1/2" Clear Vinyl 6 in
2 8.709-069.0 Clamp, Screw #4 3
3 8.706-780.0 Nipple, 1/4" Hex 2
4 9.802-254.0 Hose, 1/4" Push-on 16 in
5 8.706-941.0 Hose Barb, 1/4" x 1/4" MPT 3
6 8.706-407.0 Bushing, 1/2 x 1/4 MT x FT 3
7 8.706-393.0 Coupling, 1/2" SCH 80 3
8 8.712-417.0 Diffuser Stone, Fine Pore,
1/2" NPT 3
9 8.750-743.0 Bulkhead, 1/2" NPT Polypro 1
10 8.707-016.0 Elbow, 90°, 1/4" NPT x 3/8 1
ITEM PART NO. DESCRIPTION QTY
11 6.390-126.0 Clamp, Hose 6
12 8.707-355.0 Check Valve 1
13 8.711-733.0 Tubing 3/8" x 1/2" Clear Vinyl 15 ft
14 8.706-841.0 Tee, 1/4" Female, Pipe 2
15 9.802-064.0 Grommet, Rubber 3
16 9.919-140.0 Bracket, Air Stone 3
17 9.802-805.0 Washer, 5/16" Flat, SAE, SS 6
18 9.802-777.0 Nut, 5/16" ESNA, NC, SS 6
19 8.718-619.0 Bolt, 5/16" x 3/4" NC, GR 5 SS 6
20 8.706-878.0 Nipple, 1/4" Pipe x 1/8" Pipe 3
AUXILIARY DIGESTER ASSY EXPLODED VIEW PARTS LIST
background
8.914-458.0-G • Water Maze CLB-603
69
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-42
7
13
44
42
54" to
Tank Top
5
NOTE: Locate 5" Diameter Hole After Mounting Grass Catcher
NOTE: Only required
when HydroScreen and
HydroScreen bracket
options are ordered.
3
38, 39
40, 41
41
2
Purge
Valve Assy
(Optional)
48" to
Tank Top
36" to
Tank Top
300 Gallon
Tank
Locate 5" Diameter Hole
after Mounting Grass
Catcher
16"
FS1
20
22
43
10
48
46
47
42
13
43
29
25
21
12
30
9
39
6
51
6
31
11
8
52
32
14
15
15
16
18
17
12
12
12
21
19
24
25
23
25
26
27
29
28
33
50
53
53
50
49
34
54
37
36
35
45
30
CLT-300 TANK ASSEMBLY INSTALLATION
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
70
CLT-300 TANK ASSEMBLY PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.719-180.0 Tank, 300 Gal, Clarifi er w/o Lid 1
2 8.719-182.0 Lid, 300 Gal. Clarifi er Tank 1
3 8.706-648.0 Handle, Sandpot Lid 1
4 8.706-568.0 Handle, Rubber T, w/Keeper 3
5 8.716-142.0 Switch, Float, N/O (Black) 1
6 9.802-514.0 Strain Relief, STRT 3
7 8.706-490.0 Bulkhead, 1-1/2" Polypro 1
8 9.802-477.0 Box, Junction 1
9 8.913-142.0 Assy, Tank Stand 300 Gal.,
CLT 300 1
10 8.706-394.0 Plug 1-1/2" PVC 1
11 8.940-186.0 Label Float Switch Junction Box 1
12 8.706-366.0 Pipe, 1" PVC 80 1" x 2" Spacer 4
13 8.706-378.0 Elbow, 1" Slip x FIPT PVC 90 2
14 8.706-479.0 Bulkhead, 2" NPT Polypro 1
15 8.706-466.0 Nipple, 2" Close, PVC 80 2
16 8.706-436.0 Tee, 2" FT x FT x FT, PVC 80 1
17 8.706-418.0 Bushing Reducer, 2 x 1 PVC 80
HT x FT 1
18 8.706-409.0 Adapter, 1" MT x SLIP, PVC 80 1
19 8.706-371.0 Elbow, 1" S x S, PVC 80, 45° 1
20 8.940-221.0 Label Lifting Point 2
21 8.707-359.0 Valve, 1" S 80 PVC, S x S
Molded in Place Ball 2
22 8.900-841.0 Label Water Maze Label, Large 1
23 8.706-430.0 Tee, 1" S x S, PVC 80 1
24 8.706-397.0 Plug, 3/4" MT, SCH 80 PVC 1
ITEM PART NO. DESCRIPTION QTY
25 8.706-447.0 Bushing, 1" x 3/4" SOC x FT
PVC 80 3
26 8.706-800.0 Nipple, 3/4" Hex, Brass 1
27 8.706-846.0 Tee, 3/4" Female Pipe Brass 1
28 8.706-869.0 Plug, 3/4", Hex Head 1
29 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 2
30 9.802-152.0 Swivel, 3/4" SAE Fem,
Push-on 2
31 8.750-743.0 Bulkhead 1/2" Polypro 1
32 8.707-349.0 Valve, 2" Single Union Ball 1
33 8.706-451.0 Adapter, 2" SLIP x MT, PVC 80
(option) 1
34 8.756-648.0 Valve, Ball, 1-1/2", PNEU ACT,
NO SOL 1
35 8.706-958.0 Hose Barb, 1/4" Barb x 1/4" Pipe,
90° (option) 1
36 6.390-126.0 Clamp, Hose, .46-.54 ST 2
37 9.802-254.0 Hose, 1/4" Push-on Fuel Line
(option) 15 ft
38 8.718-760.0 Screw, 10/32" x 5/8" Pan SS 4
39 9.802-696.0 Nut, 10/32 6
40 9.802-747.0 Screw, 6/32 x 5/16 Rnd 12
41 8.718-854.0 Nut, 6/32 Keps 12
42 8.706-439.0 Nipple 1" PVC 80 2
43 8.706-484.0 Bulkhead, 1" Polypro 1
44 8.706-366.0 Pipe, 1" SCH 80 PVC 12 in
45 9.802-261.0 Hose, 3/4 Push-on 24 in
46 9.800-013.0 Label USA Intended Indoor Use 1
47 9.800-034.0 Label Clear Lexan 1
48 9.804-141.0 ETL Label 1
49 8.706-476.0 Union 2" FSX FT PVC 80
(Option) 1
50 8.706-367.0 Pipe, 1.5", PVC 80, /FT
1.5 x 2-3/4 2
51 9.802-699.0 Screw 10-32 x 3/4" Slot Pan 2
52 9.802-478.0 Lid, Plastic Carlon 1
53 8.706-413.0 Bushing, 2' X 1 1/2' SLIP,
PVC 80 2
54 8.756-650.0 Muffl er, Exhaust, 1/4" NPT,
Brass 1
background
8.914-458.0-G • Water Maze CLB-603
71
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
CLT-300 TANK ASSEMBLY OPTIONS
89144580-43
Grass Slide
Grass Catcher Assy.
Option #8.903-783.0
Bracket Option
#8.903-784.0
Debris Dumpster
Option #8.903-602.0
1
2
3
4
5
6
7
8
10
11
12
13
14
24
20
21
22
23
25
9
21
6
5
15
15
26
27
28
18
34
32
29
30
17
35
35
31
16
33
34
19
18
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
72
ITEM PART NO. DESCRIPTION QTY
1 8.913-698.0 Assy, Grass Slide, 24" 1
2 8.913-699.0 Grass Screen, 24" 1
3 8.706-424.0 Nipple, 1-1/2" Close, PVC 80 1
4 8.706-375.0 Elbow, 1-1/2" FT x FT, PVC 80
90° 1
5 8.707-169.0 Adapter, 1.5" Male x 1.5" Male
Thrd, CAM 2
6 8.707-168.0 Coupler, 1.5" Fem x 1.5" Hose
Barb, CAM 2
7 8.913-145.0 Bracket, Grass Slide 4
8 9.802-767.0 Screw, 3/8 x 3/4" Whiz Loc 4
9 9.802-071.0 Trim 1/16" Black 3.33 ft
10 9.802-781.0 Nut, 3/8" Whiz Loc 4
11 8.902-229.0 Elbow, 4" SLIP x SLIP,
PVC 40 1
12 8.902-228.0 Pipe, 4" PVC 40 24 in
13 8.706-681.0 Cart Gray Utility 1
14 8.706-403.0 Bushing 2 x 1-1/2" 1
15 8.709-080.0 Clamp, Hose 2
16 8.719-967.0 Screen, 40 Mesh, SS
97" x 17-1/2" 1
17 9.802-193.0 Gasket, Neoprene 18 ft
18 8.706-530.0 Rail, Front End 1.25 x 15" 2
19 8.706-531.0 Rail, Back End, 1.25" x 94" 2
20 8.706-469.0 Union, 1-1/2" Slip 1
21 8.706-374.0 Elbow, 1-1/2", 90°, SLIP 2
22 8.706-426.0 Tee, 1-1/2" SLIP 1
23 8.707-344.0 Valve, 1-1/2" Gate, SLIP 1
24 8.913-698.0 Hose 1-1/2" Gray Sprialite 20 ft
25 9.802-730.0 Bolt 3/8" x 2-1/2 Zinc 2
26 9.802-099.0 Washer Snubbing 2
27 9.802-807.0 Washer Flat 3/8" 2
28 9.802-779.0 Nut 3/8" 2
29 9.802-714.0 Bolt, 5/16" X 1-3/4", NC HH 4
30 9.802-805.0 Washer 5/16" Flat SAE SS 4
31 8.718-887.0 Nut 5/16" SS Whiz Loc 4
32 8.718-754.0 Screw 1/4" - 20 x 1 1/4"
Pan Head SS 4
33 8.718-747.0 Screw 1/4 x 1" SS PH PHIL 24
34 8.718-965.0 Washer 1/4" SS Flat 28
35 8.718-817.0 Nut 1/4-20 Hex Whiz-Loc SS 28
CLT-300 TANK ASSEMBLY OPTIONS PARTS LIST
background
8.914-458.0-G • Water Maze CLB-603
73
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-44
Optional Air
Solenoid/Dump
Valve Assy
(Enlarged View)
18" from
Tank Top
48" from
Tank Top
For
Detail See
Optional Oil
Skimmer/
SludgeTub
Illus.
For
Detail See
Optional Oil
Skimmer/
SludgeTub
Illus.
14" from
Top
Connected
to Air Stone
Pressure
Regulator
Air Stone Assy
56
9,10,11
13
48
57
48
48
17" from
Tank Top
Field
Installed
22" from
Tank Top
47
58
54
53
52
55
49
60
50
60
51
26
3
7
63
2
32
8
33
46
41
44
42
43
43
42
41
21
22
40
30
31
36
16
17
15
18
19
20
21
22
21
21
25
40
24
40 27
28
30
29
31
23
45
35
45
34
39
38
37
65
65
66
12
14
6
5
4
3
2
61
64
62
1
59
52
55
Optional Air Solenoid
Dump Valve Assy.
(Enlarged View)
CLT-600 TANK ASSEMBLY EXPLODED VIEW
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
74
CLT-600 TANK ASSEMBLY EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.719-177.0 Tank, 600 Gal Clarifi er w/Lid 1
2 8.706-483.0 Bulkhead, 3" FT x FT, Polypro 2
3 8.706-454.0 Adapter, 3" SLIP x MT,
PVC 40 2
4 8.706-368.0 Pipe, 3" PVC 40 24 in
5 8.706-385.0 Elbow, 3" SLIP x SLIP,
PVC 40 1
6 8.706-368.0 Pipe, 3" PVC 40 36 in
7 8.706-368.0 Pipe, 3", PVC 40 6 in
8 8.913-095.0 Assy, Tank Stand 600,
Mild Steel 1
9 8.706-648.0 Handle, Sandpot Lid 2
10 9.802-699.0 Screw 10/32 8
11 9.802-696.0 Nut 10/32 8
12 8.706-568.0 Handle, Rubber w/Keeper 3
13 9.802-747.0 Screw, 6/32 x 5/8 12
14 8.718-854.0 Nut, 6/32 12
15 8.706-479.0 Bulkhead, 2" NPT, Polypro 1
16 8.706-466.0 Nipple, 2" Close, PVC 80 2
17 8.706-436.0 Tee, 2" FT x FT x FT, PVC 80 1
18 8.706-418.0 Bushing, Reducer, 2 x 1,
PVC 80 MPT x FPT 1
19 8.706-409.0 Adapter, 1" MT x SLIP,
PVC 80 1
20 8.706-371.0 Elbow, 1" S x S, PVC 80, 45° 1
21 8.706-366.0 Pipe, 1" PVC 80 1" x 2" spacer 4
22 8.707-359.0 Valve, 1" S 80 PVC S x S 2
23 8.706-476.0 Union 2" FS x FT PVC 80
(Option) 1
24 8.706-430.0 Tee, 1" S x S. PVC 80 1
25 8.706-397.0 Plug, 3/4" MT, Sch 80 PVC 1
26 8.706-437.0 Tee, 3" S x S x S 1
27 8.706-800.0 Nipple, 3/4" Hex, Brass 1
28 8.706-846.0 Tee, 3/4" Female Pipe Brass 1
29 8.706-869.0 Plug, 3/4" Hex, Head 1
30 8.706-899.0 Nipple, 3/4" JIC x 3/4" Pipe 2
31 9.802-152.0 Swivel, 3/4" SAE Fem,
Push-on 2
32 8.706-394.0 Plug, 1 1/2" PVC 80 1
ITEM PART NO. DESCRIPTION QTY
33 8.707-349.0 Valve, 2" Single Union Ball 1
34 8.706-451.0 Adapter, 2" SLIP x MT,
PVC 80 (Option) 1
35 8.756-648.0 Valve, BalL, 1-1/2", PNEU ACT,
NO SOL 1
36 9.802-261.0 Hose, 3/4" Push-on 35 in
37 8.706-958.0 Hose Barb, 1/4" Barb x 1/4"
Pipe, 90° (Option) 1
38 6.390-126.0 Clamp, Hose, .46-.54 ST
(Option) 2
39 9.802-254.0 Hose, 1/4" Push-on,
Fuel Line 15 ft
(Option)
40 8.706-447.0 Adapter, 1", 3/4" S x FIPT
PVC 80 3
41 8.706-378.0 Elbow, 1" SLIP x FIPT
PVC 80, 90° 2
42 8.706-439.0 Nipple, 1", PVC 80, Close 2
43 8.706-484.0 Bulkhead, 1" Polypro 1
44 8.706-366.0 Pipe, 1" PVC 80 12 in
45 8.706-367.0 Pipe, 1.5", PVC 80, /FT
1.5 x 2-3/4 2
46 8.706-490.0 Bulkhead, 1-1/2" Polypro 1
47 8.711-733.0 Tubing, 3/8 x 1/2"
Clear Vinyl 15 ft.
48 8.709-069.0 Clamp, Screw #4 3
49 8.706-958.0 Hose Barb, 1/4 Barb x 1/4 Pipe 1
50 9.802-254.0 Hose, 1/4" Push-on 16 in.
51 8.706-941.0 Hose Barb, 1/4" x 1/4" Pipe 1
52 8.706-407.0 Bushing, 1/2 x 1/4 MT x FT 3
53 8.706-393.0 Coupling, 1/2" SCH 80 1
54 8.712-417.0 Diffuser Stone, Fine Pore,
1/2" NPT 1
55 8.750-743.0 Bulkhead, 1/2" NPT Polypro 1
56 8.707-016.0 Elbow, 90°, 1/4" NPT x 3/8 1
57 8.711-733.0 Tubing, 3/8 x 1/2" Clear Vinyl 6 in
58 8.707-355.0 Check Valve 1
59 8.900-841.0 Label WaterMaze Logo Large 1
60 6.390-126.0 Clamp Hose 2
61 9.800-013.0 Label USA Intended Indoor use 1
62 9.800-034.0 Label, Clear Lexan 1
63 8.706-638.0 Pipe 3" PVC 40 22 in
64 9.804-141.0 ETL Label 1
65 8.706-413.0 Bushing, 2' X 1 1/2' SLIP,
PVC 80 2
66 8.756-650.0 Muffl er, Exhaust, 1/4" NPT,
Brass 1
background
8.914-458.0-G • Water Maze CLB-603
75
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
89144580-12
OIL SKIMMER & SLUDGE TUB ASSEMBLY EXPLODED VIEW
To Main
Tank
Bottom
Cone
Oil
Collection
Funnel
Bulkhead
Through
Coalescing
Tank
Oil Collection
Barrel
1
2
3
4
4
12
14
10
19
23
21
12
24
26
15
26
26
15
11
20
26
13
21
16
17
22
18
13
9
14
14
Sludge Tub Assembly
Oil Skimmer Assembly
7
6
5
8
5
6
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
76
OIL SKIMMER & SLUDGE TUB ASSEMBLY PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.719-179.0 Tub, Sludge, w/Lid (Black) 1
2 8.913-094.0 Support, Sludge Bag 1
3 8.719-191.0 Bag, Sludge, Qty 1,
Biodegradable 5
4 8.706-479.0 Bulkhead, 2" NPT Poly 2
5 8.706-453.0 Adapter 2" MTx 2- M
Hose Insert 5
6 8.709-083.0 Clamp, 3 -1/2" SS Band 5
7 8.711-817.0 Hose 2" Clear Spiralite 21 in
8 8.711-817.0 Hose 2" Clear Spiralite 84 in
9 8.707-361.0 Valve 1 1/2" 80 PVC S x S 1
10 8.706-683.0 Funnel, Plastic Oil Skimmer 1
11 8.706-374.0 Elbow, 1.5" S x S 1
12 8.706-372.0 Elbow, 1-1/2" S x T 2
13 8.706-468.0 Nipple, 1-1/2" x 3" 1
14 8.706-490.0 Bulkhead, 1-1/2" Polypro 3
15 8.706-469.0 Union, 1-1/2" S x S 2
16 8.706-367.0 Pipe, 1-1/2" PVC 80 57 in
17 8.706-428.0 Tee, 1-1/2", S x S x T 1
18 8.719-169.0 Tank, Vertical w/Lid, 26 Gallon 1
19 8.706-492.0 Nipple, 1-1/2" x 2-1/2" 1
20 8.706-441.0 Adapter, 1.5" S x MT 1
21 8.706-424.0 Nipple 1.5 x Close PVC 80 2
22 8.706-482.0 Nipple 11/2" x 6" PVC 80 1
23 8.706-375.0 Elbow 11/2" FTx FT PVC 80 1
24 8.706-367.0 Pipe 1.5 PVC 80 14 in
25 8.706-367.0 Pipe 1.5 PVC 80 11 in
26 8.706-367.0 Pipe 1.5 PVC 80 1.5 x 21/2" 4
background
8.914-458.0-G • Water Maze CLB-603
77
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
OZONE PUMP EXPLODED VIEW
ITEM PART NO. DESCRIPTION QTY
1 8.726-026.0 Motor, 3/4 HP, 230V 1
2 NA Slinger 1
3 8.726-024.0 Pump, 3/4 HP, Wet End 1
4 NA Drain Plug 1
5 NA O-Ring, Drain Plug 1
HP Volts Phase
Size
Inlet Outlet
Running
Amps
Max.
Pressure
Max.
Water Temp.
3/4 230V 1 1-1/2" FPT/ 1-1/2"FPT/
1-1/2" MBT 1-1/2" MBT
5.7 40 PSI 104°F/40°
ITEM PART NO. DESCRIPTION QTY
6 NA O-Ring 1
7 NA Adapter, Union 1-1/2” Slip 1
8 NA Collar, Union 1
Kit:
6-8 8.750-270.0 Fitting, Compression, 1-1/2" Slip
Part # 8.917-760.0
OZONE PUMP EXPLODED VIEW PARTS LIST
40
20
0
20 40 60 80
U.S. GALLONS PER MINUTE
TOTAL HEAD IN FEET
1
2
3
4
5
6
7
8
Not Included
With Pump
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
78
OPTIONAL TRANSFER PUMP EXPLODED VIEW
8.715-402.0, 2 HP, 230V 1 PH
ITEM PART NO. DESCRIPTION QTY
1 8.718-520.0 Flinger 1
2 88-132000200 Adapter 1
3 88-118000340G Seal 1
4 8.718-534.0 5.13" Impeller 1
5 88-104000168 Washer 1
6 8.718-521.0 Nut 1
7 88-130000170 Case 1
8 88-113000348 Motor, 2 HP 230V 1 PH 1
OPTIONAL TRANSFER PUMP EXPLODED VIEW PARTS LIST
BRAND MODEL NO.
SIZE
INLET OUTLET AMPS VOLTS PHASE MAXGPM, PSI
SCOT 60 1-1/2" 1-1/4" 9.1 230 1 See Chart Above
1
2
3
4
5
6
7
8
background
8.914-458.0-G • Water Maze CLB-603
79
WATER TREATMENT SYSTEM
OPERATOR’S MANUAL
TRANSFER PUMP EXPLODED VIEW
#8.755-986.0 3/4 HP 1PH
ITEM PART NO. DESCRIPTION QTY
1 104.000.171 Flinger 1
2 132.000.337X Adapter 1
3 101.000.239 Seal VN-SIL/SIL 1
4 131.000.763D 4.88" Impeller 1
5 104.000.168 Washer 1
6 105.000.465 Nut 1
7 137.002.664X Case 1
8 Motor, 3/4 HP 230V 1 PH 1
1
2
3
4
5
6
7
8
TRANSFER PUMP EXPLODED VIEW PARTS LIST
BRAND MODEL NO.
SIZE
INLET OUTLET AMPS VOLTS PHASE MAXGPM, PSI
SCOT 11 1-1/4" 1" 5.5 230 1 See Chart Above
background
8.914-458.0-G • Water Maze CLB-603
OPERATOR’S MANUAL WATER TREATMENT SYSTEM
80
INFEED PUMP PUMP EXPLODED VIEW
INFEED PUMP PUMP EXPLODED VIEW PARTS LIST
ITEM PART NO. DESCRIPTION QTY
1 8.749-983.0 Seal 1
2 8.749-984.0 Impeller 1
3 8.725-503.0 O-Ring 1
89144580-29
1
2
3
#8.715-387.0 1/2 HP 1 PH
BRAND MODEL NO.
SIZE
INLET OUTLET AMPS VOLTS PHASE FLOW/HEAD
AMT 2852-95 1-1/4" 1-1/4" 4.0 230 1 See Chart Above
background