- 15 -
Disconnect the electrical load(s). Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E15
USB-A Ports Output
Under-voltage
Disconnect the electrical load(s). Remove the short
circuit(s). Press the DC Output Mode On/Off Button to clear
the [Error Code] icon. Connect only the electrical load(s)
with compliant current ratings to the unit.
E16
USB-A Ports Output
Over-current/Short-circuit
Disconnect the electrical load(s). Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E17
DC Output Ports/CIG Port
Output Over-voltage
Disconnect the electrical load(s). Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E18
DC Output Ports/CIG Port
Output Under-voltage
Disconnect the electrical load(s). Remove the short
circuit(s). Press the DC Output Mode On/Off Button to clear
the [Error Code] icon. Connect only the electrical load(s)
with compliant current ratings to the unit.
E19
DC Output Ports/CIG
Port Output Over-cur-
rent/Short-circuit
Disconnect the electrical load. Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E20
QC USB-A Port Output
Over-voltage
Disconnect the electrical load. Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E21
QC USB-A Port Output
Under-voltage
Disconnect the electrical load. Remove the short circuit.
Press the DC Output Mode On/Off Button to clear the [Error
Code] icon. Connect only the electrical load with compliant
current ratings to the unit.
E22
QC USB-A Port Output
Over-current/Short-circuit
Disconnect the electrical load. Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E23
USB-C PD Port Output
Over-voltage
Disconnect the electrical load. Reactivate the DC output
mode. If the [Error Code] icon persists, stop using the unit.
Contact the Renogy technical support team for help.
E24
USB-C PD Port Output
Under-voltage
Disconnect the electrical load. Remove the short circuit.
Press the DC Output Mode On/Off Button to clear the [Error
Code] icon. Connect only the electrical load with compliant
current ratings to the unit.
E25
USB-C PD Port Output
Over-current/Short-circuit
Disconnect the electrical load. Remove the short circuit. Let
the unit stand for 10 seconds. Press the AC Output Mode
On/Off Button to clear the [Error Code] icon. Connect only
the electrical load with compliant power ratings to the unit.
E26
AC Outlet Output
Overload/Short-circuit