EN 18
Gas type P mBar Modification.
Wok (BG6xB) Wok (BG6xC)
nozzle nozzle
G20 20 - 142 150
Convert from G20 / 20 mbar to:
G20 13
Replace nozzle & no action
bypass
155 170
G25 20 Replace nozzle & no action by-pass 143 152
G30/G31 28-30/37
Replace nozzle & screw in bypass
(see 3A)
94 100
G30 50
Replace nozzle & screw in bypass
(see 3A)
82 90
Gas type P mBar Modification.
Wok (BG6xB) Wok (BG6xC)
nozzle nozzle
G30 30 - 94 100
Convert from G30 / 30 mbar to:
G20 20
Replace nozzle & adjust bypass
(see 3C)
142 150
Power table (kW-gr/h):
G20
13 mbar
G25
20 mbar
G30-G31
28-30/37 mbar
G30
50 mbar
G150
8 mbar
Auxiliary burner 1.05 1.05 1.05/76 1.05 1.10
Semi-rapid burner 1.95 1.95 1.80/130 1.90 1.85
Rapid burner 3.10 3.10 3.00/216 3.00 3.00
Wok burner BG6xB) 3.45 3.35 3.50/252 3.50
Wok burner (BG6xC) 4.00 3.85 4.00/288 4.00
Contents of conversion set
Nozzles for burners and (if applicable) by-pass screws for gas taps.
Data label with the modified gas specifications and setting.
Tools needed:
T1 Socket spanner (7mm)
T2 Screw driver flat blade (4mm)
T3 Nose pliers
T4 Open end spanner (7mm)
T5 Leak test spray
CONVERSION INSTRUCTION