EN 17
CONVERSION INSTRUCTION
Conversion instruction
Adjusting for a different gas type!
Attention! Performing of these instructions by a non-qualified engineer can lead to
dangerous situations. The supplier is not responsible for the consequences (the arising
of a hazardous situation and/or damage to persons or goods) caused by incorrect
performance of these instructions by engineers who are not employees of the supplier.
Consequential damage arising through inexpert performance of these instructions is not
accepted.
With this conversion-set your gas hob can be converted to different gasses.
See conversion Table.
Conversion table
Gas
type
P
mBar
Modification
Auxiliary Semi rapid Rapid
nozzle nozzle nozzle
G20 20 - 72 97 128
Convert from G20 / 20 mbar to:
G20 13
Replace nozzle & no action
bypass
84 115 145
G25 20
Replace nozzle & no action
bypass
77 105 134
G30/
G31
28-
30/37
Replace nozzle & screw in
bypass (see 3A)
50 65 85
G150 8
Replace nozzle & adjust
bypass (see 3C)
145 200 290
G30 50
Replace nozzle & screw in
bypass (see 3A)
43 60 75
Gas
type
P
mBar
Modification
Auxiliary Semi rapid Rapid
nozzle nozzle nozzle
G30 30 - 50 65 85
Convert from G30 / 30 mbar to:
G20 20
Replace nozzle & adjust bypass
(see 3C)
72 97 128