20. Slide the carriage bolt to the end of the slot in the lower pulley assembly using a 17mm wrench.
Item Description Qty.
1 Carriage Bolt, M10 x 1.5, 50mm 1
Tighten hardware to 20-25  (27.1-33.9 Nm).
21. Install screws and washers securing the lower pulley assembly to the tower frame using an 8mm Allen wrench.
Item Description Qty.
1 Lower Pulley Assembly 1
2 Tower Frame 1
3 Washer, Flat 3/8" 4
4 Screw, M10 x 1.5, 25mm 4
Tighten hardware to 20  (27.1 Nm).
Install Work Arm Assembly
1. Install screws and washers securing the pivot support assembly to the tower frame using an 8mm Allen wrench.
Item Description Qty.
1 Pivot Support Assembly 1
2 Tower Frame 1
3 Screw, M10 x 1.5, 25mm 4
4 Washer, Flat 3/8" 4
Loosely hand tighten hardware.