24 Euromaid 540mm Upright Cooker INSTALLING THE GAS COOKER
Gas connection
A Inletpipejoint
B Gasket
C Stableunion
Procedure
Maketheconnectiontothegassystemusingarigid
metalpipeandregulationunions,orwithastainless
steelhosecomplyingwiththelocalstandard.Ifmetal
hosesareused,takecarethattheydonotcomeinto
contactwithmobilepartsandarenotcrushed.
Whenmakingtheconnection,takecarenottoapply
stressesofanykindtotheappliance.
Readthesepointsbeforeconnectingtothegassupply;
• Thegasconnectionpointisa1/2”BSPexternal
threadlocatedattherearoftheapplianceasshown
intheRearView.
• Aregulatorissuppliedfornaturalgasappliances
whichmustbettedinthesupplylinetothe
appliance.ForLPGthesuppliedbrassTestPoint
Adapter/Fittingmustbettedtothesupplyline.
• Itisrecommendedtottheregulatorortestpoint
ttingtotheapplianceconnectionpoint,thent
eitherhardpipingoraexibleconnectionfrom
theregulatorortestpointttingtoconsumerhard
piping.Ensureinstallationallowswithdrawalof
appliance.ForexiblehoseinstallationAS/NZS
5601.1clauses5.9and6.10.1.9mustbefollowed.
Unpacking
Donotttheburnercrowns,burnercapsandtrivets
untilafterthecookerhasbeeninstalled.
Checking gas pressures
Beforeinstallationcheckthatthecookerissuitablefor
thegassupply.Todothischeckthegastypeonthe
cartonstickeroronthedataplatebehindthebottomof
theovendoor.Ifthecookerisrequiredtobeusedwith
LPG,thesuppliedconversionkitmustbeused.
Thefollowingshowsthesupplyandoperating
pressuresforvariousgassupplies.
Operatepressureatappliancetestpoint:
1.00KPa(Naturalgas);N2.75KPa(UniversalLPGgas)
Thefollowingtableshowstheinjectorsizesforeach
burner.
Injector Natural gas Universal LPG
Auxiliaryburner 0.93mm 0.57mm
Semi-rapidBurner 1.16mm 0.71mm
TripleringBurner 1.75mm 1.10mm
Connection to the gas supply
ThegasConnectionmustbemadeinaccordance
withthelocalstandards.
Wheninstalling,tasafetytapattheendofthe
pipeline.Theapplianceleavesthefactorytested
andsetforthetypeofgasindicatedonthe
plateinsidethebottomguard,closetothegas
connectionpipe.Makesurethatthetypeofgasto
besuppliedtotheapplianceisthesameasthat
shownontheplate.
Formaximumefciencyandminimumconsumption,
makesurethatthegassupplypressurecomplies
withthevaluesshowninthegasusedisdifferent
fromthatspecied(orvariable).asuitablepressure
regulatormustbeinstalledonthesupplypipeline.