Euromaid 540mm Upright Cooker INSTALLING COOKER – POWER CONNECTIONS 23
Fitting on a Power Supply Cable
WARNING: Installtion MUST ONLY be carried out by a qualified approved installer, ie. an Electrician.
Connectingappropriatepowersupply`terminalboard/connectorblock:
NOTE: REFER to TECHNICAL tables at the rear of this manual for correct rating for your
corresponding model purchased.
• Usingascrewdriver,prizeopentabsoftheTerminalboardcover.
• Removethewireclampscrew.
• Fastenthewiresbeneaththecorrespondingscrewheads,usingbrass‘bridge’forsinglephasesupply.
• Fastencableclampandclosethecoveroftheterminalboard.
• TheACpowersupplyshouldbe220-240V,50Hz.Forelectriccookers,theminimum45Afuse,oratleast45Aa
distributioncircuitbreaker.Forgascookers,theminimum20Afuse,oratleast20Acircuitbreaker.
WARNING:Connectthepowercordmustbeinaccordancewiththeinstructionslistedinthetablebelow
Connection mode
L1 L2 N E
1N~ Min6 Min6 Min6
2N~ Min1.5 Min2.5 Min6 Min6
Connecting the supply cable to the mains
Installanapprovedcircuitbreakerwithaminimumcontactopeningof3mm,betweentheapplianceandthemains
fusebox.Thecircuitbreakershouldbesizedaccordingtotheloadandshouldcomplywithcurrentregulations(the
earthwireshouldnotbeinterruptedbythecircuitbreaker).
Thesupplycableshouldbepositionedsothatitdoesnotreachatemperatureofmorethan50ºCwithrespecttothe
roomtemperature,anywherealongitslengthBeforeswitchingfuseONinmeter-boxcheck:
• Earthcontinuity.Theelectricalsafetyofthisappliancecanonlybeguaranteedifthecookeriscorrectlyinstalled
andearthed,incompliancewithregulationsonelectricalinstallations.
• Theelectricalcapacityofthesystemandsocketswillsupportthemaximumpoweroftheappliance,asindicated
onthedataplate
• Gotosection19“Installingyournewcooker”
NOTE:AllUprightcookersmustcomplytolocalregulationstoAustralianStanadrdAS/NZS3000:2007
guidelines.QualiedElectricianwillhaveacopyoftheseguidesthatMUSTbeadheredto.
Installing cooker – power connections
Wire cross-sectional
area (mm
2
)