13
Installation of the Beer Tower
Remove the top plug by twisting and pulling out, saving it for later use if you decide to convert unit to
an all-refrigerator.
Unravel the beer line (clear hose) from the tower and insert the beer line and wing nut through the
uncovered hole on top.
Lock the beer tower assembly to the top and make sure to position the beer faucet so it is aligned with
the cabinet front (6 o’clock position). You accomplish this by aligning the bottom of the beer tower to
the 3 grooves on the top cabinet and tighten by hand clockwise to properly lock.
WARNING
THE BEER TOWER ASSEMBLY OF YOUR UNIT COMES WITH A FLAT MYLAR WASHER.
YOUR UNIT MAY NOT REQUIRE THE USE OF THIS WASHER AS TOWER IS DESIGNED FOR A
TIGHT AND SECURE FIT.
HOWEVER, WHILE INSTALLING THE TOWER TO THE UNIT THIS WASHER CAN BE USED FOR A
TIGHTER FIT IF NECESSARY.
Connecting the Beer Tower to Coupler
Make sure the washer is properly inserted into the wing nut.
Place wing nut into the top of the coupler, turning until tight.
How to Tap a Keg of Beer
Make sure the beer tower faucet is in the closed position.
Pull tapping handle out and press downward until it locks into
position. (See Figure 8) The keg is now tapped.
Figure 8
Adjusting the C0
2
regulator
The gauge monitors low internal keg pressure and should be adjusted to 10-12 PSI.
Release the adjustment lock nut by turning clockwise. Turn the regulator screw to make the
adjustment.
Turn clockwise to increase pressure or counterclockwise to decrease pressure.
Figure 9
When you have adjusted the pressure regulator to the correct pressure, retighten the lock nut by
turning counterclockwise.
Open the secondary shut-off valve to allow gas to flow into the keg.
Allow several minutes for the keg to properly pressurize. The regulator gauge may show a drop in
pressure while this happens. (See Figure 9)
Note: Listen for a hissing sound at all connections to determine if there are any leaks.
OPEN POSITION
When the gas pressure exceeds 50 PSI,
the pressure relief valve will open and
gas will be released.
Gas line connection
Pressure release valve
Shut-off valve
Pressure gauge
Adjustment lock nut
Regulator screw