Installation Instructions
STEP 6:
,QVWDOOWKH89&$LU&XWRႇ$VVHPEO\
5HPRYHWKH89&$LU&XWRႇDVVHPEO\IURPWKHNLWSDFNDJLQJDQGLQVWDOOLWLQWRWKHXQLWZKHUHWKHROGDLUFXWRႇZDV
SODFHG5HSHDWWKHSUHYLRXVVWHSVLQUHYHUVHRUGHUWRLQVWDOOWKHFXWRႇ7KHULJKWHQGRIWKHDLUFXWRႇVKRXOGVOLSLQWR
the right fan blade support and the left end can be guided into the left fan blade support.
%HFDUHIXOQRWWRGDPDJHWKHLQGRRUFRLOZKHQLQVWDOOLQJWKHQHZ89&FXWRႇ7KH89&EUDFNHWZKLFKLVDWWDFKHGWR
WKHXQGHUVLGHRIWKH89&$LU&XWRႇVKRXOGEHSRVLWLRQHGMXVWEHKLQGWKHLQGRRUFRLO
7KHZLUHKDUQHVVVKRXOGEHUHWDLQHGWDXWDVLWZDVVKLSSHGXQGHUWKHDLUFXWRႇWRDYRLGLQFLGHQWDOFRQWDFWZLWKWKH
fan blade.
7LJKWHQWKHVFUHZVWKDWZHUHORRVHQHGRQWKHOHIWIDQEODGHVXSSRUWVLQ67(3
&DUHIXOO\VSLQWKHLQGRRUIDQEODGHWRPDNHVXUHWKDWQRWKLQJLVLQWHUIHULQJZLWKLWVPRWLRQ7KHIDQEODGHVKRXOGVSLQ
freely without any objectionable noises.
STEP 7:
Installation of the Vent Trim
3ODFHWKHYHQWWULPWKDWZDVUHPRYHGLQ67(3
2. Route the UVC wiring through the notch in the vent trim for the thermistor wires. On 265V models the UVC wiring
will share this opening with the thermistor wires. Make sure wires are not pinched.
3. Reinstall the seven 5/16” screws removed previously.
5HFRQQHFWWKHWKHUPLVWRUZLUHLISUHVHQWWRWKHZLULQJKDUQHVVIURP67(3
Use existing thermistor wire
path for UVC wiring harness