6
WARNING
USE OF SETBACK TEMPERATURES
Do not use motion sensing setback temperatures in rooms
where incapacitated persons or animals are unable to change
the control setting.
An unattended air conditioner with extreme setbacks may
result in undesirable or unhealthy temperatures in the
conditioned space causing under heating, under cooling or
death of persons or animals.
4. To select first unoccupied set back temperature, press the HEAT key until feature code comes up. To
scroll to a previously viewed feature codes, press the COOL key.
Once you have scrolled to the feature, press either the up or down arrow to scroll to the desired first unoc-
cupied setback temperature. Cooling example: 72
0
(guest set point) + 2
0
(Setback temperature) = 74
0
(operational
set point).
5. Press HEAT key to scroll to first unoccupied setback time. The first unoccupied setback time is the time
between when the control determines that the room is not occupied and when the control sets the operating set
point temperature back. The increments are in hours (.1 = 6 mins., .5 = 30 mins., 1 = 1 hour, etc.). Press either the
up or down arrow to the desired first unoccupied setback time. Example: Operating set point would be 74
0
in-
stead of 72, 30 minutes (.5 hours) after guest leaves room.
6. To select second unoccupied setback temperature, press the HEAT key until comes up. Press either the
up or down arrow to the desired second unoccupied setback temperature.
7. Press HEAT key to scroll to second unoccupied setback time. Press either the up or down arrow to
the desired second unoccupied setback time.
8. Press HEAT key to scroll to third unoccupied setback temperature. Press either the up or down arrow
to the desired third unoccupied setback temperature.
9. Press HEAT key to scroll to third unoccupied setback time. Press either the up or down arrow to the
desired third unoccupied setback time.
10..To exit configuration mode:
Press the OFF key. NOTE: Configuration feature mode will also automatically exit if no keys are pressed
for a period of two (2) minutes.
The changes made in configuration mode are now in effect.
NOTE: Additional codes are present and may be accessed within this menu. Contact the manufacturer for additional