Baumatic BGG60 Gas Hobs

User Manual - Page 25

For BGG60. Also, The document are for others Baumatic models: BGG30, BGG32, BGG64, BGG70

PDF File Manual, 32 pages, Read Online | Download pdf file

BGG60 photo
Loading ...
Loading ...
Loading ...
Gas adjustment (Conversion to LPG)
All work must be carried out by a GASSAFE registered
engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o Remove the pan-stands, burners and
flame spreaders (A).
o Unscrew the injector (B) and replace it
with the stipulated injector for the new
gas supply (see table on next page).
GENERAL INJECTORS TABLE
Power (in watts) Kind of gas Nozzle
mm/100
Burners
Max. Min.
Natural 95/55/95
129
97
76
Wok
Rapid
Semi-rapid
Auxiliary
3800
3000
1750
1000
1700
1500
900
500
L.P.G.
Butane
Propane
65/41/65
87
65
51
Wok
Rapid
Semi-rapid
Auxiliary
3800
3000
1750
1000
1300
700
400
350
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
25
Loading ...
Loading ...
Loading ...