11
(testing cont.)
Check all connections from the supply line, or LP cylinder up to and including the manifold pipe
assembly.
Soap bubbles will appear where a leak is present.
If a leak is present, immediately turn off gas supply, tighten any leaking fittings, turn the gas sup-
ply back on, and recheck.
If you cannot stop a gas leak turn off the gas supply and call your dealer where you purchased
your unit.
Do not use the unit until all connections have been checked and do not leak.
Only those parts recommended by the manufacturer should be used on the unit.
Substitution can void the VERSAPOWER™ Cooking System warranty.
IMPORTANT NOTE:
ALWAYS CHECK FOR LEAKS AFTER EVERY LP TANK CHANGE.
If a leak is present, or if the connection hose shows signs of wear, these conditions must be corrected
prior to using your VERSAPOWER™ Cooking System.
Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy water
near the shut-off valve of the gas supply line. Spray all the fittings. Bubbles indicate leaks.
LIGHTNING INSTRUCTIONS:
BEFORE LIGHTNING
The pressure regulator and hose assembly supplied with the unit
must be used. Never substitute regulators other than those sup-
plied with the unit. If a replacement is necessary, contact the fac-
tory for proper replacement.
Screw the regulator (Type QCC1) into the LP tank. Leak check the
hose and regulator connections with a soap and water solution be-
fore operating as explained on the LEAK TESTING section of this
manual.
BURNERS LIGHTING:
Turn all knobs to “OFF” then turn on the gas supply. Always keep your face and body as far away from
the unit as possible when lighting. Depress the igniter button for the burners and immediately push and
turn the burner control knob counter-clockwise to the “HI” position and wait for the burner to light. (See
illustration on next page)
NOTE: The first burner may take longer to light while air is purged from the gas supply system.
If the burner does not light in 4 seconds, turn knobs to “OFF” and wait 5 minutes to allow any accumu-
lated gas to dissipate before trying again. If the burner will not light after several attempts, then it can be
lit with a match.
WARNING
THE COVER MUST BE RE-
MOVED BEFORE LIGHTING.
THE COVER SHOULD NOT BE
IN PLACE WHEN USING THIS
UNIT. DAMAGE WILL OCCUR.
WARNING
DO NOT ATTEMPT TO LIGHT
THE GRILL IF THE ODOR OF
GAS IS PRESENT.