Alfresco AGVPCNG 24 Inch BuiltIn Single Side Burner with 65,

User Manual - Page 10

For AGVPCNG.

PDF File Manual, 20 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
10
NG FLEXIBLE HOSE
1/2” FPT X 1/2” MPT
90° ELBOW
CONVERTIBLE GAS PRESSURE
REGULATOR
SHUT OFF HAND VALVE
MUST BE LOCATED IN
ACCESIBLE AREA
INCOMING NG
GAS SUPPLY
Figure # 3
LEAK TESTING:
GENERAL:
Although all gas connections on your ALFRESCO™ VERSAPOWER™ Cooking System are leak tested
at the factory prior to shipment, a complete gas tightness check must be performed at the installation site
due to possible mishandling in shipment, or excessive pressure unknowingly being applied to the unit.
Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.
BEFORE TESTING:
Make sure that all packing material is removed from the unit.
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle, or brush.
For LP units, always check with a full cylinder.
TO TEST:
Make sure all control valves are in the “OFF” position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
1/2” FPT X 3/8” COMP
BRASS FITTING
Loading ...
Loading ...
Loading ...