Binder MKF 720 Dynamic climate chamber with humidity control, -liter capacity

User Manual - Page 12

For MKF 720.

PDF File Manual, 177 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
MKF / MKFT (E5) 06/2020 page 12/176
1.6 Type plate
The type plate sticks to the left side of the chamber, bottom right-hand, above the refrigerating and hu-
midity module.
Figure 2: Type plate (example of MKFT 240 regular unit)
Indications of the type plate (example)
Information
BINDER
Manufacturer: BINDER GmbH
MKF 56
Model designation
Alternating climate chamber
Device name
Serial No.
00000000000000
Serial no. of the chamber
Built
2020
Year of construction
Nominal temperature
180 °C
356°F
Nominal temperature
IP protection
20
IP type of protection acc. to standard EN 60529
Temp. safety device
DIN 12880
Temperature safety device acc. to standard DIN 12880
Class
2.0
Class of temperature safety device
Art. No.
9020-0383
Art. no. of the chamber
Project No.
---
Optional: Special application acc. to project no.
6,50 kW
Nominal power
12,0 A
Nominal current
400 V / 50 Hz
Nominal voltage +/- 10% at the indicated power fre-
quency
3 N ~
Current type
Max operating pressure 29 bar
Max operating pressure in the refrigerating system
Stage 1: R 452A - 2,20 kg
Cooling 1
st
stage: Refrigerant type, filling weight
Stage 2: R 23 0,40 kg
Cooling 2
nd
stage: Refrigerant type, filling weight
Symbol on the type plate
Information
CE conformity marking
Electrical and electronic equipment manufactured /
placed on the market in the EU after 13 August 2005
and be disposed of in separate collection according to
the Directive 2012/19/EU on waste electrical and elec-
tronic equipment (WEEE).
GS mark of conformity of the “Deutsche Gesetzliche
Unfallversicherung e.V. (DGUV), Prüf- und Zertifizier-
ungsstelle Nahrungsmittel und Verpackung im DGUV
Test(German Social Accident Insurance (DGUV), Test-
ing and Certification Body for Foodstuffs and Packaging
Industry in DGUV Test). (Not valid for MKF056-240V)
Nominal temp.
180 °C
6,50 kW / 12,0 A
Max. operating pressure 29 bar
356 °F
400 V / 50 Hz
Stage 1: R 452A2,20 kg
IP protection
20
Stage 2: R 23 - 0,40 kg
Safety device
DIN 12880
3 N ~
Contains fluorinated greenhouse gases
Class
2.0
covered by the Kyoto Protocol
Art. No.
9020-0383
Project No.
Built
2020
Alternating climate chamber
BINDER GmbH
Im Mittleren Ösch 5
78532 Tuttlingen / Germany
www.binder-world.com
MKFT 240
E5
Serial No. 00000000000000
Made in Germany