Minimum drill depth in concrete:
Standard fasteners 1/2” beyond anchor length
Metric fasteners 10mm beyond anchor length
Minimum concrete embedment:
KH-EZ 3/8”: 3-1/4” (83mm)
HUS-H 8mm: 75mm (2-3/32”)
Pullout Force
Cybex specifies Hilti™ static and dynamic anchors. According to the anchor manufacturer, the recommended
design pullout force (in tension) for the specified anchors, when properly installed in cracked concrete, is provided
in the side table. This table should be used for reference only; for additional and up-to-date information on the
anchor capabilities or the design pullout force in other substrates, please consult Hilti directly at
https://www.us.hilti.com.
Design Resistance in Tension *Selected Anchor
830 lbKH-EZ ¼” x 4”
3.3 kNHUS-H 6MM x 120MM
1535 lbKH-EZ 3/8” x 4”
1535 lbKH-EZ 3/8” x 5”
3.3 kNHUS-H 8MM x 120MM
3.3 kNHUS-H 8MM x 150MM
2000 lbHSL-3/8 4”
8 kNHST M12 x 115/20
8 kNHST M12 x 195/200
1615 lbKB-TZ 3/8” x 3-3/4”
* Design strength extracted from the Hilti Anchor Fastening Technology Manual issued September 2014.
Tools Required
Adhere to manufacturer’s equipment warnings and guidelines. Follow manufacturer’s
instructions for proper usage.
Static Anchor
Floor scanner/rebar detector (optional)
1” L-shape SDS rotary hammer
1/4" x 12" (6mm x 305mm) carbide drill bit (for 1/4” (6mm) anchors)
3/8" x 12" (8mm x 305mm) carbide drill bit (for 3/8” (8mm) anchors)
Safety glasses
Extension cord
Impact wrench
Vacuum (for debris)