Installation instructions
500 x 50 mm
Oven with
cooling fan
500 x 10 mm
4 mm
4 mm
Thermal protection barrier
500 x
10 mm
80 mm
Clearances
A
B
C
C
E
EE
D
Clearances (mm)
CI604DT
CI754DT
CI905DT
A
minimum clearance from rear edge of cutout to:
nearest combustible surface
55 55 53
B
minimum clearance from glass surface to:
rangehood 650 650 650
C
minimum clearance from side edges of cutout to:
nearest combustible surface
85 78 80
D
minimum clearance from benchtop to:
overhead cabinet not directly above the
cooktop 450 450 450
E
minimum clearance below top of benchtop to:
top of oven* installed below cooktop (see Fig.1)
thermal protection barrier (see Fig.2)
90
75
90
75
90
75
WARNING!
This cooktop requires
adequate supply of fresh,
cool air to fully function.
The base of the cooktop
must have direct
unrestricted ventilation to
the room where the
cooktop is installed. Follow
the requirements below.
Fig. 1 Minimum clearances and ventilation
requirements - oven installed below cooktop
* The oven installed below the cooktop MUST have a cooling fan.
Fig. 2 Minimum clearances and ventilation
requirements - cupboard or drawer space below