Operator Specifications
Usage Classification
Class I, II, III, & IV
Main AC Supply 120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps
When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated
208/240/480/575 VAC, 5.2/4.5/2.3/1.9 A, 60 Hz, 1 PH
System Operating Voltage
24 Vdc Transformer Run / Battery Backup
Accessory Power
24 Vdc, 1A max. for ON + SW (switched)
Solar Power Max
24 Vdc at 60 watts max.
Maximum Gate Weight/Length
14 ft. - 2,800 lbs.
16 ft. - 2,400 lbs.
18 ft. - 2,200 lbs.
20 ft. - 1,800 lbs.
22 ft. - 1,500 lbs.
To optimize performance and extend operator life, the long arm kit model HDLGARM is
recommended when installing with gates 16ft. or longer. See Accessories page 53.
When HDLGARM is used, operator has the following maximum gate weight/length:
14 ft. - 4,500 lbs.
16 ft. - 3,750 lbs.
18 ft. - 3,250 lbs.
20 ft. - 2,750 lbs.
22 ft. - 2,500 lbs.
90 Degree Travel Time 13-36 seconds NOTE: Travel time will vary based on arm configuration and speed controlsettings.
Maximum Travel Range 115 degrees NOTE: Travel range will very based on arm configuration.
Maximum Daily Cycle Rate
Continuous
Maximum Duty Cycle
Continuous
Operating Temperature
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
External Entrapment Protection Device Inputs
(non-contact and/or contact)
Main board - up to 2 close entrapment protection devices and 1 open entrapment protection device.
Expansion board - up to 3 entrapment protection devices configurable to either the close or open
direction and up to 8 edge sensors when using the wireless edge sensor kit model LMWEKITU and
LMWETXU.
27.85" (70.7 cm)
14.82" (37.6 cm)
16.77" (42.6 cm)
1.31" (3.3 cm)