Fulgor Milano F7SCO24S1 24 Inch BuiltIn Single Steam Wall Ov

User Manual - Page 31

For F7SCO24S1.

PDF File Manual, 68 pages, Read Online | Download pdf file

F7SCO24S1 photo
Loading ...
Loading ...
Loading ...
EN
29
Electrical connections
Be sure your appliance is properly installed and grounded
by a qualified technician. Ask your dealer to recommend a
qualified technician or an authorized repair service.
This appliance is manufactured is with a green GROUND wire
connected to the oven body. After making sure that the power
has been turned off, connect the flexible conduit from the
oven to the junction box using a U.L. listed conduit connector.
Figures A and B and the instructions provided below present
the most common way of connecting the ovens.
Your local codes and ordinance, of course, take precedence
over these instructions. Complete electrical connections
according to local codes and ordinance.
WARNING
Risk of Electric Shock, frame grounded to neutral of appliance
through a connection.
Ground through the neutral conductor is prohibited for new
branch-circuit installation (1996 NEC); mobile homes; and
recreation vehicles, or in an area where local codes prohibit
grounding through the neutral conductor. For installations where
grounding through the neutral conductor. For installations
where grounding through the neutral conductor is prohibited:
Disconnect the ground from the neutral at free end of conduit;
Use grounding terminal or lead to ground unit; and usual
procedure.
3-Wire branch circuit (for US only)
Refer to Figure A, where local codes allow the connection of
GROUND wire from the oven to the branch circuit NEUTRAL
wire (gray or white colored wire):
- If local codes permit, connect the green GROUND wire from
the oven and the white wire from the oven to the branch
circuit NEUTRAL wire (gray or white colored wire).
- Connect the red and black leads from the oven to the
corresponding leads in the junction box.
GROUNDED NEUTRAL
White wires
Cable from
power supply
Junction box
UL listed conduit
connector
Red wires
Black wires
Cable
from oven
Bare or
green wire
A
4-Wire branch circuit (for US and CANADA)
Refer to Figure B:
- Connect the green GROUND wire from the oven to the
GROUND wire in the junction box (bare or green colored
wire).
- Connect the red and black leads from the oven to the
corresponding leads in the junction box.
- Connect the white wire from the oven to the NEUTRAL (gray
or white) wire in the junction box.
UNGROUNDED NEUTRAL
Red wires
Junction box Cable from
power supply
White wires
Black wires
UL listed conduit
connector
Cable
from oven
Bare or
green wire
B
Loading ...
Loading ...
Loading ...