Installation Instructions
CONNECT THE RANGE TO GAS
Shut off the main gas supply valve before disconnecting
the old range and leave it off until the new hookup has
been completed. Don’t forget to relight the pilot on other
gas appliances when you turn the gas back on.
Because hard piping restricts movement of the range,
the use of a CSA International-certified flexible metal
appliance connector is recommended unless local codes
require a hard-piped connection.
Never use an old connector when installing a new range.
If the hard piping method is used, you must carefully
align the pipe; the range cannot be moved after the
connection is made.
To prevent gas leaks, put pipe joint compound on, or
wrap pipe thread tape with Teflon* around, all male
(external) pipe threads.
A. Install a manual gas line shut-off valve in the gas line in
an easily accessed location outside of the range. Make
sure everyone operating the range knows where and
how to shut off the gas supply to the range.
B. Install male 1/2 flare union adapter to the 1/2 NPT
internal thread at inlet of regulator. Use a backup
wrench on the regulator fitting to avoid damage.
B. When installing the range from the front, remove the
90° elbow for easier installation.
C. Install male 1/2 or 3/4 flare union adapter to the
NPT internal thread of the manual shut-off valve,
taking care to back-up the shut-off valve to keep it
from turning.
D. Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
E. When all connections have been made, make sure
all range controls are in the off position and turn on
the main gas supply valve. Use a liquid leak detector
at all joints and connections to check for leaks in
the system.
When using test pressures greater than 1/2 psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve
from the gas supply piping. When using test pressures
of 1/2 psig or less to test the gas supply system, simply
isolate the range from the gas supply system by closing
the individual shut-off valve.
*Teflon: Registered trademark of DuPont
2
WARNING: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
PROVIDE ADEQUATE
GAS SUPPLY
Your range is designed to operate at a pressure
of 10 of water column on LP gas (propane or
butane) or, if designed for natural gas, 4 of
water column.
Make sure you are supplying your range with the
type of gas for which it is designed.
This range is convertible for use on natural or
propane gas. If you decide to use this range on
natural gas, conversion must be made by a
qualified installer before attempting to operate
the range on that gas.
For proper operation, the pressure of LP gas
supplied to the regulator must be between 10
and 13 of water column.
For natural gas, the pressure supplied must be
between 4 and 13 of water column.
When checking for proper operation of the
regulator, the inlet pressure must be at least 1
greater than the operating (manifold) pressure
as given above.
The pressure regulator located at the inlet of the
range manifold must remain in the supply line
regardless of whether LP or natural gas is being
used.
A flexible metal appliance connector used to
connect the range to the gas supply line should
have an I.D. of 1/2 and be 5 feet in length for
ease of installation. In Canada, flexible
connectors must be single wall metal connectors
no longer than 6 feet in length.