20 21
TROUBLESHOOTING
If you have any further problems or queries please contact the Tefal
Customer Relations Helpline - see details at the end of this leaflet.
Problems Possible causes Solutions
There is no steam. The appliance has not been
turned on.
Check that the appliance has been plugged in correctly.
Next press the On/Off pedal, the power indicator light
located at the front of the appliance will come on.
The hose has been obstructed. Check that the hose is not bent or twisted. The device
will begin producing steam after approximately 60
seconds.
There is no water left in the
water tank.
Switch off the appliance and fill the water tank.
The steam flow is low. Your steamer has a build-up of
scale because it has not been
rinsed out regularly.
See descaling process (Cleaning paragraph).
The hose has been
obstructed.
Check that the hose is not bent or twisted.
There is no water left in the
water tank.
Switch off the appliance and fill the water tank.
The steam is not ready yet. The appliance will produce steam about 60 seconds
after it has been switched on.
Water runs through the holes
of the steam head.
There is condensation in
the hose.
Never use a steamer in the horizontal position. Hold
the hose vertically outstretched and wait for the
condensed water to return to the steamer.
The steamer takes a long time
to heat and/or ejects white
particles.
Your steamer has a build-up of
scale because it has not been
descaled regularly.
See descaling process
(Cleaning paragraph).
The Roll & Press system panel
is crooked.
The panel didn’t roll back
correctly.
Unroll the panel again and keep your hand on the
handle while rolling back to the top.
The Roll & Press system panel
rolled back up while in use.
The panel didn’t roll back
correctly.
Make sure the Roll & Press handle is firmly locked
in the hook. It should not be moving horizontally or
vertically.
The hose makes a
gurgling noise.
You are using the steam
head in a position close
to the ground and some
condensation occurs in the
hose.
Raise the hose frequently during use and adjust the
pole to its maximum height in order to avoid
the formation of condensation.
Water is overflowing from
water tank.
You are using the steam
head in a position close
to the ground and some
condensation occurs in the
hose.
Raise the hose frequently during
use and adjust the pole to its
maximum height in order to avoid
the formation of condensation.
handle while the panel is rolling back to the top.
WARNING: never let go of the handle until the panel has totally rolled back.
Once the appliance is switched off, it is recommended to wait several minutes so that the
Roll & Press panel has dried before rolling it back.
• Empty and rinse the water tank each time before storage in order to flush out any scale
particles (fig. 22).
• Loosely wind up the electrical cord and close with the Velcro strip, then hang it from the clip
on the pole (fig.23 - fig. 24).
• Do not carry the steamer by the water tank handle. This appliance includes luggage style
wheels for added convenience when transporting.
WARNING: Never touch the head until it has cooled down completely.
1 • Transport
• Your appliance is fitted with two wheels for ease of transport. Tilt the appliance towards the
rear holding the pole and then pull along to transport.
• You can also lift up the appliance in order to transport it, again holding the appliance by
the pole.
Do not attempt to lift up or transport the appliance holding the Roll & Press panel, the pedal,
the water tank handle or the built-in hanger. Always roll back the Roll & Press panel before
transporting the appliance. Always make sure the pole is firmly attached to the base unit
before lifting up the appliance (see assembly instructions).
2 • Cleaning
• Clean the main unit with a damp cloth.
• Clean the Roll & Press system panel with a damp cloth or non abrasive sponge.
Do not use any cleaning products such as soap or detergents.
• Always handwash the delicates steam cap and wait until it is totally dry before using again.
• To maintain maximum performance, your steamer must be descaled occasionally.
The time between descaling operations depends on the quality of the water and the
frequency with which you use the appliance. The appliance must be descaled at least once
a year or after 50 hours of use.
• To carry out a descaling operation, follow the following steps:
1. Ensure that the appliance has cooled down completely (2 hours minimum).
2. Fill the water tank with fresh untreated tap water and place it on the main unit
allowing water to fill the boiler.
3. Remove the water tank from the base and empty out the water via the water tank
filling hole by tipping the appliance over a sink. Limescale and other impurities can
be rinsed away.
4. Repeat step 2 and 3 several times until all the scale has been removed.
CAUTION: Don’t fill the boiler by the steam head holes!
Never immerse the steam head in water!
9100021252-01 IS6300 M2-D2.indd 21 21/07/2016 10:41