3. Clean the drainage hose and siphon
connecting piece.
4. Reattach the drainage hose and
secure the connection using the
hose clamp.
Filter in the water supply
blocked
First, reduce the water pressure in the
supply hose:
1. Turn off the tap.
2. Select any program (except Rinse//
Spin/Empty).
3. Press the A button.Allow the
program to run for approximately 40
seconds.
4. Turn the program selector to Off.
Pull out the mains plug.
5. Clean the filter on the tap:
Disconnect the hose from the tap.
Clean the filter with a small brush.
6. For standard and Aqua-Secure
models, clean the filter on the rear of
the appliance:
Remove the hose from the rear of
the appliance.
Use pliers to remove the filter and
then clean it.
7. Connect the hose and check for
leaks.