9
External Open Limit External Safety Limit External Close Limit
R1 LED
R2 LED
R3 LED
OFF
ON
OFF
OFF
OFF
ON
ON
OFF
OFF
NOTE: Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3.
SP MODE 1
SP (SPECIAL MODES) MODE 1
This mode allows a second set of external, track mounted limits to act as primary or backup for the operator’s open, close, and safety
limits. The position of these limits can be set either before or after the operator’s limits. This mode would be used in lieu of previous
modification 90-42104.
NOTE: It is not required that all three inputs have a switch connected to the TLS1CARD. Either the external close, external safety,
external open, or all three may be used.
Outputs:
Connect a red light to the R1 terminals on the TLS1CARD. This will signal that the external close limit switch has been activated.
Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the external open limit switch has been activated.
Connect a yellow light to the R3 terminals on the TLS1CARD. This will signal that the external safety limit switch has been
activated.
Required Inputs:
Connect external CLOSE limit switch common and normally open contacts to the COMMON (#10) and FD/SIS (#11) terminals on
the TLS1CARD respectively.
Connect external OPEN limit switch common and normally open contacts to the COMMON (#10) and T/TS (#12) terminals on the
TLS1CARD respectively.
Connect external SAFETY limit switch common and normally open contacts to the COMMON (#10) and SIC (#9) terminals on the
TLS1CARD respectively.
Disconnect power to the operator.
Turn DIP switches 1, 3, and 4 on the TLS1CARD to the ON position. DIP switch 2 should remain OFF.
Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below.
1
2
3
1
234
O
N
SP MODE 1 DIP SWITCH SETTINGS
TLS1CARD
40-35757-1
Timer Light Status Option Card
R3
R2
R1
6
5
4
3
2
1
T/TS 12
FD/SIS 11
COMMON 10
SIC 9
SIO 8
COMMON 7
INPUTS
5 A, 230 Vac, 30 Vdc Dry Contact Only
(RELAYS)
OUTPUTS
* External Track Mount
Limit Switch
*OLS
*CLS
*SLS
SP MODE 1 (TYPICAL CONNECTION)
After configurations and connections have been made for your card mode proceed to Installation page 10.