Fully Open
(OLS)
Timer Stage 1
(OLS Only)
Timer Stage 2
(Pre-Warning)
(OLS Only)
Closing
Fully Closed
(CLS)
Opening Undefined
Stopped
Position (USP)
Open Mid-Stop
(OMS)
Reversing from
Obstruction
R1 LED
R2 LED
R3 LED
OFF
ON
ON*
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON*
ON
OFF
ON*
ON
OFF
ON*
ON
OFF
OFF
NOTES:
Relay LEDs R1, R2, and R3 on the TLS1CARD will turn ON at the same time as relays R1, R2, and R3.
* R3 turns ON as soon as SIO is enabled and remains ON until closing begins.
TCP MODE 5
TCP (TRAFFIC CONTROL MODE WITH PRE-WARNING) MODE 5
Similar to Mode 2, this mode is intended as a special input to open the door without activating the Timer-to-Close (TTC) while any other
open signal will activate the TTC with Pre-Warning. It provides dry contact control based on the position/movement of the door and the
TTC status. The relays can be used with or without the timers programmed. An open signal from the standard push button or a radio
input would not re-enable the timer if the special input to open has been enabled. This mode would be used in lieu of previous
modification 90-T3.
Outputs:
Connect a red light to the R1 terminals on the TLS1CARD. This will signal the door is not fully open or not fully closed.
Connect a green light to the R2 terminals on the TLS1CARD. This will signal that the door is fully open.
Connect an audio/signalling device to the R3 terminals on the TLS1CARD. This will signal that the door has been opened by the
special input to open (SIO) and the timer is not enabled.
Inputs:
Connect a push button, selector switch, loop detector, etc. to the SIO input terminals. This will open the door without enabling
the TTC.
If the application warrants the use of Timer Secure mode at some times and Timer modes at other times, set the operator selector
dial to TS and make a connection to the T/TS input. The input should have a latched contact, such as a 2-position maintained
keyswitch to switch between TS and T.
Disconnect power to the operator.
Turn DIP switch 2 on the TLS1CARD to the ON position. All other DIP switches should remain OFF.
Connect the auxiliary device(s) to the input and output terminals on the TLS1CARD as described below.
1
2
3
1
234
O
N
TCP MODE 5 DIP SWITCH SETTINGS
After configurations and connections have been made for your card mode proceed to Installation page 10.
TLS1CARD
40-35757-1
Timer Light Status Option Card
R3
R2
R1
6
5
4
3
2
1
T/TS 12
FD/SIS 11
COMMON 10
SIC 9
SIO 8
COMMON 7
(RELAYS)
OUTPUTS
INPUTS
5 A, 230 Vac, 30 Vdc Dry Contact Only
N.O.
Comm
N.O.
Comm
N.O.
Comm
Horn/Strobe
Green
Red
TCP MODE 5 (TYPICAL CONNECTION)
2-Position
Maintained Switch
Momentary
Push Button