INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
38
ArtNo.102-0011 - Pressure test point
Pressure Testing
Connect the appliance to the gas supply. Check the appliance
is gas sound.
The gas pressure can be measured at the pressure test point
on the appliance side of the pressure regulator (Fig.8.11).
For proper operation, the pressure of LP supplied to the
regulator must be between 10’ and 13’ of water column
(2.49 – 3.24 kPa).
When checking for proper operation of the regulator, the
inlet pressure must be at least 1’ (0.25 kPa) greater than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range
manifold must remain in the supply line regardless of
whether natural or LP gas is being used.
To Fit the Storage Drawer
Note: To avoid exterior damage to the storage drawer. Ensure
a soft cushioned mat is placed on the oor and covers the
width and depth of the storage drawer.
Align the two holes on either side of the storage drawer with
the runner brackets (Fig.8.12).
Fasten the two fasteners and screws washers on either side of
the Storage Drawer.
Close drawer and check the alignment. Adjust storage drawer
position accordingly.
Check the alignment is correct and ensure all fasteners are
fully tightened.
Check the appliance is gas sound.
DO NOT use a ame to check for gas leaks.
When using test pressures greater than ½ psig to pressure
test the gas supply system of the residence, disconnect the
range and individual shut-o valve from the gas supply
piping. When using test pressures of ½ psig or less to test
the gas supply system, simply isolate the range from the gas
supply system by closing the individual shut-o valve.
Check the operation of all the burners.
Fig.8.11
Fig.8.12