Locating Your Grill
4
When selecting a suitable loca-
tion, take into account concerns
such as exposure to wind and
trac paths. Try to keep all gas
supply lines as short as possible.
Never locate the grill in a build-
ing, garage, shed or other such
enclosed area. A carpenter’s
spirit level” should be used to
assure that the unit is level both
front-to-back and side-to-side.
If it is not level, burner combus-
tion may be erratic or the unit
may not function eciently. If
the oor is uneven or has a de-
cided slope, re-leveling may be
required after each moving of a
freestanding unit.
BUILT-IN INSTALLATIONS:
The LYNX Built-In Grill is designed
for easy installation into mason-
ry enclosures. For non-combus-
tible applications, the grill drops
into the opening shown in the
cutout detail drawing and hangs
from its counter-top trim. A deck
is not required to support it from
the bottom. When using the in-
sulated jacket in a combustible
enclosure, the jacket must be
supported from the bottom by a
ledge on each side or a full deck
beneath the jacket. Review the
detailed drawing and pay spe-
cial attention to the provisions
shown for gas line hook-up. It is
recommended that the enclo-
sure have ventilation holes to
prevent gas build-up in the event
of a leak. The deck ledges and
counter should be at and level.
If your grill is equipped with a ro-
tisserie, electrical service should
be provided (on the Left Side of
most models).
REAR HOOD CLEARANCE:
Clearance is required behind the
grill to allow the front hood to
open (see gure 4-1). 27” and 36
models require a minimum of 2”
clearance, while 30”, 42” and 54”
models require a minimum of
4” clearance. The grill exhausts
combustion products and cook-
ing greases to the back. Never lo-
cate the grill where this exhaust
will be dicult to clean.
4" min. for all other sizes
2" min. for 27" grills
Figure 4-1
- Required clearance
to allow opening of front hood.
CLEARANCE TO COMBUSTIBLE
CONSTRUCTION:
Minimum clearance from sides
and back of unit to adjacent
combustible construction below
top of unit are 12” from sides and
12” from back.
Dégagement minimal entre les
parois latérales et l’arrière de
l’appariel et la construction com-
bustible au-dessous du panneau
supérieur de lappareil (30 cm à
partir des parois latérales et 30 cm
à partir de l’arrière).
Minimum horizontal clearance
from sides and back of unit to
adjacent vertical combustible
construction extending above
top of unit is 12” from sides and
12” from back.
Dégagement horizontal minimal
entre les parois latérales et l’arrière
de lappariel et la construction
verticale combustible au-dessus
de lappareil (30 cm à partir des
parois latérales et 30 cm à partir
de l’arrière).
Do not use this appliance under
overhead combustible surfaces.
Ne pas utiliser cet appareil sous
une surface combustible.
A minimum of 6of clearance is
needed on each side of the grill
for the motor and skewer.
If the grill is to be placed into a
combustible enclosure, an ap-
proved insulated jacket is neces-
sary and is available from your
LYNX dealer. Use only a LYNX in-
sulated jacket as it has been de-
signed and tested specically for
your Grill. Refer to next page for
cutout dimensions.
WA R N I N G
Installing this product
into a combustible en-
closure without an insu-
lated jacket could result
in re, property damage
and personal injury.