OPERATION
Controls (Fig. 2)
The hood is operated using the (5) push-buttons located on the hood and the remote control.
LED colors are displayed on hood control only.
FIG. 2
(P1) Delay- Off Switch
• Yourhoodincludesa10minuteblowerdelayoffswitch.Pressthisswitchoncetoactivatethe
timer and the LED Ring (L1) flashes blue. The blower will continue to operate for 10minutes.
After 10 minutes, the blower turns off automatically.
To cancelthe10-minutedelay,pressthedelayswitchonceagain.
(P2) Filter Alarm Switch
• After30hoursofbloweroperation,thefilteralarmisactivatedandtheLEDring(L1)turnsred/
flashes. It indicates that the grease filters need to be cleaned.
• Aftercleaningthegreasefilters,resetthehourcounterbypressingtheFilterAlarm/TimerReset
button (P2) during display of the alarm.
(P3) Blower Speed Decrease and Off Switch
• Press to decrease blower speed, high to low.The LED ring (L1) flashesblue at a speed
proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
• Continuepressingthisswitchtoturnthebloweroff.
(P4) Blower Speed Increase and On Switch
• Pressthisswitchtoturntheblowerontolowspeed.
• Pressagaintoincreaseblowerspeed,lowtohigh.TheLEDring(L1)flashesblueataspeed
proportionate to the blower setting (i.e.: four flashes is high speed, one flash is low speed, etc.)
(P5) Light Switch
Turns the lights on and off.
P1: Activate/deactivate delay-off (10 minute)
P2: Filter change indication timer reset
P3: Decreases fan motor speed until turned off (4>3>2>1>OFF)
P4: Turns fan motor on and increased speed (ON>1>2>3>4)
P5: Turns lights on/off
L1: LED Indicator Ring Signalling crown:
- Hood in standby: lights up green. 30 seconds after
the last key has been pressed the crown turns off
- Motor on: L1 lights up blue
The
frequency is proportional to the speed setting.
- 10’ TIMER function : L1 lights up and flashes blue.
- Filter alarm active: L1 lights up red
L1
LED
RING
+
-
ƒ
¤
(P1)
(P2)
(P3)
(P4)
(P5)
Auto Shut-Off Feature
If the blower and/or the lights are on continuously for 10 hours without any user interaction with
the controls, the hood will automatically shut off. Press any control button to re-activate the hood.