Installation instructions
In Canada:
Wiring must conform to Cana dian Electrical Code
C22.1- latest edition. You can obtain a copy of the
Canadian Electrical Code by writing to: Canadian
Standards Association 178 Rexdale Boulevard
Rexdale (Toronto), Ontario, Canada M9W 1R3
4. Wire size (Copper or Aluminum wire) and
connections must be suitable for the rating of
the appliance as per the National Electrical
Code requirements. The flexible armoured
cable extending from the oven should be
connected directly to the junction box.
5. The junction box should be located so as to
allow as much slack as possible between the
junction box and the oven so it can be moved
if servicing is ever required.
6. A U.L. listed conduit connector must be
provided at each end of the power supply
cable.
Electrical connections
Be sure your appliance is properly installed and
grounded by a qualified technician. Ask your
dealer to recommend a qualified technician or
an authorized repair service.
This appliance is manufactured with a green
GROUND wire connected to the oven chassis.
After making sure that the power has been turned
off, connect the flexible conduit from the oven to the
junction box using a U.L. listed conduit connector.
The figures and the instructions provided below
present the most common way of connecting the
ovens.
Your local codes and ordinances, of course, take
precedence over these instructions.
WARNING” Risk of Electric Shock, frame
grounded to neutral of appliance through a link.
Grounding through the neutral conductor is
prohibited for new branch-circuit installations (1996
NEC); mobile homes; and recreational vehicles, or
in an area where local codes prohibit grounding
through the neutral conductor. For installations
where grounding through the neutral conductor is
prohibited:
Disconnect the ground from the neutral at
free end of conduit;
Use grounding terminal or lead to ground unit;
and
Connect neutral terminal or lead to branch
circuit neutral in usual manner.
3-Wire branch circuit (for US only)
Refer to the following Figure, where local codes
allow the connection of GROUND wire from the
oven to the branch circuit NEUTRAL wire (gray or
white colored wire):
If local codes permit, connect the green
GROUND wire from the oven and the white
wire from the oven to the branch circuit
NEUTRAL wire (gray or white colored wire).
Connect the red and black leads from the
oven to the corresponding leads in the
junction box.