Loading ...
Loading ...
Loading ...
14
CONVERSION PROCEDURE (to convert to Natural gas or to ULPG)
REPLACING THE INJECTORS
This appliance is suitable for use with Natural gas or ULPG (check the “gas type” sticker
attached to the appliance). A label stating the type of gas used after replacing the
injectors must be attached at the rear of the appliance, in proximity of the gas inlet
connection. The nominal gas consumption and injector size details are provided in
table at page 16.
To replace the injectors proceed as follows:
Remove pan supports and burners from the cooktop.
Using a spanner, remove the injector J (figs. 14a, 14b) and replace it with one
according to the gas type (see following tables - page 16).
Affix to the rear of the appliance, in proximity of the gas inlet connections, the
warning label (supplied with the conversion kit) stating that the cooker has
been converted for use with ULPG / Natural gas.
IMPORTANT
If the cooker is suitable for use with Natural gas and must be converted for use
with ULPG, before connecting to gas main remove the appliance gas regulator
and replace with test point adaptor (see figs. 10-11)
If the cooker is suitable for use with ULPG and must be converted for use with
Natural gas, before connecting to the gas main remove the appliance test point
adaptor and replace with gas regulator (see figs. 10-11).
NOTE:
Gas regulator and test point adaptor are supplied with the appliance (packed with
conversion kit)
The burners are designed so that regulation of primary air is not required.
Figure 14a
J
Figure 14b
J
Loading ...
Loading ...
Loading ...