Loading ...
Loading ...
Loading ...
31
Note: Do not use abrasives or chemicals such as steel wool or alcohol when you clean the chest strap, as they can
damage the electrodes permanently.
,IWKH&RQVROHGRHVQRWGLVSOD\DKHDUWUDWHYDOXHWKHWUDQVPLWWHUPD\EHDWIDXOW&KHFNWKDWWKHWH[WXUHGFRQWDFW
areas on the chest strap are making contact with your skin. You may need to lightly wet the contact areas. Check that
the curve of the transmitter is oriented upward. If no signal appears or you need further assistance, call your Nautilus
Representative.
Before discarding a chest strap, remove the battery. Dispose of in accordance with local regulations and/or
at approved recycling centers.
Remote Heart Rate Monitor
0RQLWRULQJ\RXU+HDUW5DWHLVRQHRIWKHEHVWSURFHGXUHVWRFRQWUROWKHLQWHQVLW\RI\RXUH[HUFLVH&RQWDFW+HDUW5DWH
&+5VHQVRUVDUHLQVWDOOHGWRVHQG\RXUKHDUWUDWHVLJQDOVWRWKH&RQVROH7KH&RQVROHFDQDOVRUHDGWHOHPHWU\+5VLJ
QDOVIURPD+HDUW5DWH&KHVW6WUDS7UDQVPLWWHUWKDWRSHUDWHVLQWKHN+]N+]UDQJH
Note: The heart rate chest strap must be an uncoded heart rate strap from Polar Electro or an uncoded POLAR
®
com
patible model. (Coded POLAR
®
heart rate straps such as POLAR
®
OwnCode
®
chest straps will not work with this
HTXLSPHQW
If you have a pacemaker or other implanted electronic device, consult your doctor before using a wireless
chest strap or other telemetric heart rate monitor.
Contact Heart Rate Sensors
&RQWDFW+HDUW5DWH&+5VHQVRUVVHQG\RXUKHDUWUDWHVLJQDOVWRWKH&RQVROH7KH&+5VHQVRUVDUHWKHVWDLQOHVVVWHHO
parts of the Handlebars. To use, put your hands comfortably around the sensors. Be sure that your hands touch both the
WRSDQGWKHERWWRPRIWKHVHQVRUV+ROG¿UPEXWQRWWRRWLJKWRUORRVH%RWKKDQGVPXVWPDNHFRQWDFWZLWKWKHVHQVRUVIRU
the Console to detect a pulse. After the Console detects four stable pulse signals, your initial pulse rate will be shown.
Once the Console has your initial heart rate, do not move or shift your hands for 10 to 15 seconds. The Console will now
YDOLGDWHWKHKHDUWUDWH0DQ\IDFWRUVLQÀXHQFHWKHDELOLW\RIWKHVHQVRUVWRGHWHFW\RXUKHDUWUDWHVLJQDO
• 0RYHPHQWRIWKHXSSHUERG\PXVFOHVLQFOXGLQJDUPVSURGXFHVDQHOHFWULFDOVLJQDOPXVFOHDUWLIDFWWKDWFDQLQWHUIHUH
with pulse detection. Slight hand movement while in contact with the sensors can also produce interference.
• Calluses and hand lotion may act as an insulating layer to reduce the signal strength.
• 6RPH(OHFWURFDUGLRJUDP(.*VLJQDOVJHQHUDWHGE\LQGLYLGXDOVDUHQRWVWURQJHQRXJKWREHGHWHFWHGE\WKHVHQVRUV
• 7KHSUR[LPLW\RIRWKHUHOHFWURQLFPDFKLQHVFDQJHQHUDWHLQWHUIHUHQFH
If your heart rate signal ever seems erratic after validation, wipe off your hands and the sensors and try again.
Heart Rate Calculations
<RXUPD[LPXPKHDUWUDWHXVXDOO\GHFUHDVHVIURP%HDWV3HU0LQXWH%30LQFKLOGKRRGWRDSSUR[LPDWHO\%30E\
DJH7KLVIDOOLQKHDUWUDWHLVXVXDOO\OLQHDUGHFUHDVLQJE\DSSUR[LPDWHO\RQH%30IRUHDFK\HDU7KHUHLVQRLQGLFDWLRQ
WKDWWUDLQLQJLQÀXHQFHVWKHGHFUHDVHLQPD[LPXPKHDUWUDWH,QGLYLGXDOVRIWKHVDPHDJHFRXOGKDYHGLIIHUHQWPD[LPXP
KHDUWUDWHV,WLVPRUHDFFXUDWHWR¿QGWKLVYDOXHE\FRPSOHWLQJDVWUHVVWHVWWKDQE\XVLQJDQDJHUHODWHGIRUPXOD
<RXUDWUHVWKHDUWUDWHLVLQÀXHQFHGE\HQGXUDQFHWUDLQLQJ7KHW\SLFDODGXOWKDVDQDWUHVWKHDUWUDWHRIDSSUR[LPDWHO\
BPM, whereas highly trained runners may have readings of 40 BPM or lower.
7KH+HDUW5DWHWDEOHLVDQHVWLPDWHRIZKDW+HDUW5DWH=RQH+5=LVHIIHFWLYHWREXUQIDWDQGLPSURYH\RXUFDUGLRYDV
cular system. Physical conditions vary, therefore your individual HRZ could be several beats higher or lower than what is
shown.
Loading ...
Loading ...
Loading ...