Loading ...
Loading ...
Loading ...
67
TROUBLESHOOTING
ENGLISH
ezDispense
Symptoms Possible Cause & Solution
Refill Alarm
continues to
display when
detergent/
softener is added.
Detergent/softener has built up on the fluid level sensor.
Open the compartment covers and clean the insides of the
ezDispense
compartments with warm water. Use a soft
brush to remove any residue. If the
Refill Alarm
is
displayed continuously, call for service.
The amount of detergent/softner is not enough for the
sensor to detect.
Fill the detergent/softner up to the
MAX
line in the
compartment.
Too much/too
little detergent or
softener
dispensed.
The default dispense amounts setting may need to be
changed.
Check and change the default dispense amounts setting.
The ezDispense
doesn't dispense
detergent/
softener.
The ezDispense function is off.
Turn on the
ezDispense
function.
The ventilation holes are blocked.
Clean the ventilation holes for the lids on the
compartments with warm water.
The detergent or softener in the ezDispense
compartments has hardened.
• Clean the
ezDispense
compartments and change the
detergent or softener.
There's foam on
the rinsing course,
and there's
detergent left on
the clothes after
the washing.
Detergent was used when rinsing.
Please make sure that the detergent/softner is stored
correctly. (right: detergent / left: softener)
After the washing,
there's a scum on
the cloth.
You need to clean the inside of the ezDispense system.
When using both dispensers for liquid detergent, make
sure to run the
ezDispense Nozzle Clean
in advance.