LaView LV-KND996P1616D16-T3 16 Channel NVR Security System with 16x 1080P Dome IP Cameras

User Manual - Page 126

For LV-KND996P1616D16-T3.

PDF File Manual, 199 pages, Read Online | Download pdf file

LV-KND996P1616D16-T3 photo
Loading ...
Loading ...
Loading ...
User Manual of LV-N9916C6E Series NVR
126
8.6 Setting Alarm Response Actions
Purpose:
Alarm response actions will be activated when an alarm or exception occurs, including Full Screen Monitoring,
Audible Warning (buzzer), Notify Surveillance Center, Upload Picture to FTP, Trigger Alarm Output and Send
Email.
Full Screen Monitoring
When an alarm is triggered, the local monitor (VGA, HDMI or BNC monitor) display in full screen the video image
from the alarming channel configured for full screen monitoring.
If alarms are triggered simultaneously in several channels, their full-screen images will be switched at an interval of
10 seconds (default dwell time). A different dwell time can be set by going to Menu >Configuration>Live View >
Full Screen Monitoring Dwell Time.
Auto-switch will terminate once the alarm stops and you will be taken back to the Live View interface.
Note: You must select during Trigger Channel settings the channel(s) you want to make full screen monitoring.
Audible Warning
Trigger an audible beep when an alarm is detected.
Notify Surveillance Center
Sends an exception or alarm signal to remote alarm host when an event occurs. The alarm host refers to the PC
installed with Remote Client.
Note: The alarm signal will be transmitted automatically at detection mode when remote alarm host is configured.
Please refer to Chapter Configuring Remote Alarm Host for details of alarm host configuration.
Email Linkage
Send an email with alarm information to a user or users when an alarm is detected.
Please refer to Chapter Configuring Email for details of Email configuration.
Trigger Alarm Output
Trigger an alarm output when an alarm is triggered.
1. Enter Alarm Output interface.
Menu> Configuration> Alarm> Alarm Output
Select an alarm output and set alarm name and dwell time. Click Schedule button to set the arming schedule
of alarm output.
Note: If Manually Clear is selected in the dropdown list of Dwell Time, you can clear it only by going to
Menu> Manual> Alarm.
Figure 8. 16 Alarm Output Setup Interface
Loading ...
Loading ...
Loading ...