Mitsubishi MUYGL09NA-U1 M-Series 9,000 BTU Single Zone Outdoor Cooling Unit MUYGL09NA

User Manual - Page 69

For MUYGL09NA-U1.

PDF File Manual, 76 pages, Read Online | Download pdf file

MUYGL09NA-U1 photo
Loading ...
Loading ...
Loading ...
11-2. MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA
NOTE: Turn OFF the power supply before disassembly.
OPERATING PROCEDURE PHOTOS/FIGURES
1. Removing the cabinet
(1) Remove the screws of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the screws fixing the conduit cover.
(6) Remove the conduit cover.
(7) Remove the screw of fixing the conduit plate.
(8) Remove the conduit plate.
(9) Remove the top panel.
(10)
Remove the valve cover.
(11)
Disconnect the power supply and indoor/outdoor connect-
ing wire.
(12)
Remove the screws of the cabinet.
(13)
Remove the cabinet.
(14)
Remove the screws of the back panel.
(15)
Remove the back panel.
Photo 3
Photo 4
Photo 1
Photo 2
69
Screws of the cabinet
Screws of the top panel
Screws of the top panel
Screw of the back panel
Screws of the cabinet
Screws of
the cabinet
Screws of the service panel
Screw of
the valve
cover
Screws of
the cabinet
Screws of
the back
panel
Screws
of the
cabinet
Screws of the conduit cover
Screw of the conduit plate
OBH733J
Loading ...
Loading ...
Loading ...