Mitsubishi MUYGL09NA-U1 M-Series 9,000 BTU Single Zone Outdoor Cooling Unit MUYGL09NA

User Manual - Page 56

For MUYGL09NA-U1.

PDF File Manual, 76 pages, Read Online | Download pdf file

MUYGL09NA-U1 photo
Loading ...
Loading ...
Loading ...
56
Check the outdoor fan motor.
(Refer to 10-5.
.)
Is the fuse (F901) blown on the in-
verter P.C. board?
Check the connection of the connectors
(CN931, CN932) of the outdoor fan motor.
If the connection is poor, make it correct.
Operate the outdoor unit by starting
EMERGENCY OPERATION.
Check the LED indication on the in-
verter P.C. board.
Does the LED blink 10 times?
Replace the inverter P.C. board.
Check the corresponding parts
following LED indication.
(Refer to 10-3.)
Yes
No
Yes
(10-time blink)
No
L Check of inverter P.C. board
OBH733J
Loading ...
Loading ...
Loading ...