Loading ...
Loading ...
Loading ...
12
AA
B
B
A
NON-COMBUSTIBLE
SURFACE
=
INSTALLATION
Locating Built-in Clearances
Insulated jacket
If the grill is to be placed into a combustible enclosure, an approved insulated jacket is necessary.
Insulated jackets are available from your dealer. Use only the DCS by Fisher & Paykel insulated jacket
which has specifically been designed and tested for this purpose. Review the detail drawing shown
(Fig. 10) and take into account the provisions shown for gas line hook-up clearance in the right rear
corner. It is required that ventilation holes are provided in the enclosure to eliminate the potential
build-up of gas in the event of a gas leak. The supporting ledges or deck must be level and flat and
strong enough to support the grill and insulated jacket. The counter should also be level.
IMPORTANT!
Installing this product into a combustible enclosure without an insulated jacket could result in fire,
property damage and personal injury.
Fig. 08
**DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure or decorative
structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that
are capable of transferring heat or being ignited and burned. Such material shall be considered
combustible even though flame-proofed, fire-retardant treated or surface-painted, or plastered.
Clearances to combustible construction**
A minimum of 310mm from the sides and rear of grill must be maintained to adjacent vertical
combustible construction, above the counter top level. There should be a minimum clearance of
610mm from the top of the grill lid while it is open to allow for exhaustion of heat. You should take
in account that a large volume of heat and smoke will exhaust from the rear of the grill. This may
discolour or damage unprotected areas (Fig. 01b). Do not install under unprotected combustible
construction without using a fire safe ventilation system.
A 310mm minimum clearance must be maintained under the counter top to combustible
construction. The clearance can be modified by a use of an insulated jacket.
PRODUCT DIMENSIONS MM
A
Minimum distance from combustible surface to grill
310
B
Minimum clearance from top of grill lid while open
610
COMBUSTIBLE
SURFACE
=
Loading ...
Loading ...
Loading ...