Bosch Power Tools 1 609 92A 3FC | (4.8.16)
Note: If the sequence of switching off then on again is not followed, no cal-
ibration is performed. The signal LED 2 remains either yellow or red, even
though no metal is located within the vicinity. In this case, repeat the cal-
ibration.
Troubleshooting Causes and Corrective Measures
Cause Corrective Measure
Signal LED 2 does not illuminate.
Measuring tool is not
switched on
Switch the measuring tool on.
Measuring tool has
switched itself off
Switch the measuring tool off and then on again.
Batteries have not
been inserted or been
inserted incorrectly
Insert batteries. Pay attention to the polarity.
Flat or rechargeable
batteries inserted
Replace batteries. Do not use rechargeable bat-
teries.
Signal LED 2 illuminates yellow or red, even though no metal is
located within the vicinity (warning of metal objects).
Ambient temperature
is too high/too low
Only use the measuring tool within the specific
temperature range of 0 °C40 °C.
Severe temperature
change
Wait until the measuring tool acclimates to the
ambient temperature.
Auto calibration not
successful
Perform a manual calibration.
* Therefore, please also observe other information sources (e.g. construction plans)
before drilling, sawing or routing into walls, ceilings or floors.