COMPLAINT CAUSE SOLUTION
Unit does not operate.
The unit is turned to the off position, or the
thermostat is satised.
Turn the unit to the on position and raise or lower
temperature setting (as appropriate) to call for
operation.
The LCDI power cord is unplugged.
Plug into a properly grounded 3 prong receptacle.
See “Electrical Rating Tables” on Page 6 for the
proper receptacle type for your unit.
The LCDI power cord has tripped (Reset
button has popped out).
Press and release RESET (Listen for click. Reset
button latches and remains in.) to resume operation.
The circuit breaker has tripped or the
supply circuit fuse has blown.
Reset the circuit breaker, or replace the fuse as
applicable. If the problem continues, contact a
licensed electrician.
There has been a local power failure.
The unit will resume normal operation once power
has been restored.
Unit Trips Circuit Breaker or
Blows Fuses.
Other appliances are being used on the
same circuit.
The unit requires a dedicated outlet circuit, not shared
with other appliances.
An extension cord is being used.
Do NOT use an extension cord with this or any other
air conditioner.
The circuit breaker or time-delay fuse is
not of the proper rating.
Replace with a circuit breaker or time-delay fuse of
the proper rating. See “Electrical Rating Tables” on
Page 6 for the proper circuit breaker/ fuse rating for
your unit. If the problem continues, contact a licensed
electrician.
LCDI Power Cord Trips
(Reset Button Pops Out).
The LCDI power cord can trip (Reset
button pops out) due to disturbances on
your power supply line.
Press and release RESET (Listen for click. Reset
button latches and remains in.) to resume normal
operation.
Electrical overload, overheating, or cord
pinching can trip (Reset button pops out)
the LCDI power cord.
Once the problem has been determined and
corrected, press and release RESET (Listen for
click. Reset button latches and remains in.) to
resume normal operation.
NOTE: A damaged power supply cord must be replaced with a new power supply cord obtained from the
product manufacturer and must not be repaired.
Unit Does Not Cool/ Heat Room
Sufciently, or Cycles On And Off
Too Frequently.
The return/ discharge air grille is blocked.
Ensure that the return and/ or discharge air paths are
not blocked by curtains, blinds, furniture, etc.
Windows or doors to the outside are open. Ensure that all windows and doors are closed.
The temperature is not set at a cool
enough/ warm enough setting.
Adjust the Temperature control to a cooler or warmer
setting as necessary.
The lter is dirty or obstructed.
Clean the lter, (see Routine Maintenance), or
remove obstruction.
The indoor coil or outdoor coil is dirty or
obstructed.
Clean the coils, (see Routine Maintenance), or
remove obstruction.
There is excessive heat or moisture
(cooking, showers, etc.) in the room.
Be sure to use exhaust vent fans while cooking or
bathing and, if possible, try not to use heat producing
appliances during the hottest part of the day.
The temperature of the room you are
trying to cool is extremely hot.
Allow additional time for the air conditioner to cool off