To ensure proper unit operation, the air lter should be cleaned at least
monthly, and more frequently if conditions warrant. The unit must be turned
off before the lter is cleaned.
To Remove, Wash and Replace Filter
Lower front panel (Figure 2). Use the handle on the lter to ex lter up and
out of retainer. Remove lter from unit (Figure 3). Clean the lter monthly or
more frequently if needed. Refer to the Accessories section for lter options.
Coils & Chassis
NOTE: Do not use a caustic cleaning agent on coils or base pan. Use a
biodegradable cleaning agent and degreaser. The use of harsh
cleaning materials may lead to deterioration of the aluminum
ns or the coil end plates.
The indoor coil and outdoor coils and base pan should be inspected
periodically (annually or semi-annually) and cleaned of all debris (lint,
dirt, leaves, paper, etc.) as necessary. Under extreme conditions, more
frequent cleaning may be required. Clean the coils and base pan with a
soft brush and compressed air or vacuum. A pressure washer may also be
used; however, you must be careful not to bend the aluminum n pack. Use
a sweeping up and down motion in the direction of the vertical aluminum n
pack when pressure cleaning coils.
NOTE: It is extremely important to insure that none of the electrical
and/ or electronic parts of the unit get wet. Be sure to cover all
electrical components to protect them from water or spray.
Decorative Front
Use a damp (not wet) cloth when cleaning the control area to prevent water
from entering the unit, and possibly damaging the electronic control.
The decorative front and the cabinet can be cleaned with warm water and a
mild liquid detergent. Do NOT use solvents or hydrocarbon based cleaners
such as acetone, naphtha, gasoline, benzene, etc.
The indoor coil can be vacuumed with a dusting attachment if it appears
to be dirty. DO NOT BEND FINS. The outdoor coil can be gently sprayed
with a hose if you can get to it. If not, you might call your dealer for a more
thorough cleaning when needed.
The air lter should be inspected weekly and cleaned if needed by
vacuuming with a dust attachment or by cleaning in the sink using warm
water and a mild dishwashing detergent. Dry the lter thoroughly before
reinstalling. Use caution, the coil surface can be sharp.
Fan Motor & Compressor
The fan motor & compressor are permanently lubricated and require no
additional lubrication.
Wall Sleeve
Inspect the inside of the wall sleeve and drain system periodically (annually
or semi-annually) and clean as required. Under extreme conditions, more
frequent cleaning may be necessary. Clean both of these areas with an
antibacterial and antifungal cleaner. Rinse both items thoroughly with water
and ensure that the drain outlets are operating correctly. Check the sealant
around the sleeve and reseal areas as needed.
Before calling for service, please check the “Troubleshooting Tips” section on
Pages 46 and 47. This may help you to nd the answer to your problem,
avoid unnecessary service calls, and save you the cost of a service call if
the problem is not due to the product itself. If you have checked the “Basic
Troubleshooting” section and still need help, it is available as follows:
You can nd the name of your local Authorized Service Provider by visiting our
website at www.friedrich.com.
If you require further assistance
You can call the Customer Support Call Center at 1-800-541-6645.
Before calling, please make sure that you have the complete model and serial
number, and date of purchase of your equipment available. By providing us
with this information, we will be better able to assist you.
Our specialists are able to assist you with:
Specications and Features of our equipment.
Referrals to dealers, and distributors.
Use and Care Information.
Recommended maintenance procedures.
Installation information.
Referrals to Authorized Service Providers and Parts depots.
Routine Maintenance Service and Assistance
Available Accessories
DC-2 Drain Kit – Part No. 01900235
In some installations, excess condensate water caused by extremely humid
conditions, may result in an undesirable water drip such as on a patio or over
an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be installed
to drain excess condensation to an alternate location.
Carbon Filter Kits
The kits vary depending on the chassis size (small, medium, large). Each kit
contains three (3) lters.
KWCFS Carbon lter kit for small chassis models.
KWCFMCarbon lter kit for medium chassis models.
KWCFL Carbon lter kit for large chassis models.
FriedrichLink
Adapter Accessory
KWIFI FriedrichLink
Adapter Accessory for wireless control and
additional programming options.
Decorative Color Front Panel Kits
The kits vary depending on the chassis size (small, medium, large).
KWBGE(S/ M/ L)A – S/ M/ L Decorative Front Cover in Classic Beige
KWBLK(S/ M/ L)A – S/ M/ L Decorative Front Cover in Black Onyx
KWBLU(S/ M/ L)A – S/ M/ L Decorative Front Cover in Cobalt Blue
KWPNK(S/ M/ L)A – S/ M/ L Decorative Front Cover in Pink Diamond
KWRED(S/ M/ L)A – S/ M/ L Decorative Front Cover in Deep Red
KWWHT(S/ M/ L)A – S/ M/ L Decorative Front Cover in Designer White
Window Installation Kits (Standard in Kühl Models without Heat)
KWIKS For all KES and KHS models.
KWIKM For all KEM and KHM models.
KWIKL For all KEL and KHL models.
See www.friedrich.com for additional accessories for your unit.
Loading ...
Loading ...
Loading ...