INSTALLATION
EXHAUST HOOD REQUIREMENTS
When using an exhaust hood, the area
above the cooking surface of the grill
must be covered with a hood larger than
the cooking area of the grill, AND with
a minimum of 1200 CFM (cubic feet per
minute) for proper outdoor application
SIDE AND REAR WALL CLEARANCES
Clearance between grill and combustible
wall (Clearance Fig. 3). The grill must have a
minimum of 18” right, le and rear clearance
from any combustible wall.
BACK SPLASH CLEARANCE
(
IF APPLICABLE
)
If a non-combustible backsplash exists, it
must have a minimum of a 4” clearance
from the rear of the grill (to allow for proper
ventilation and help prevent dangerous
overheating. Clearance Fig. 4).
IMPORTANT NOTES:
This 4” backsplash clearance must first be met
prior to any non-combustible walls beginning
behind it.
OVERHEAD CONSTRUCTION AND
EXHAUST HOOD REQUIREMENTS
IMPORTANT NOTES:
DO NOT use this appliance under
unprotected combustible overhead
construction.
When installed under overhead non-
combustible construction, an exhaust
hood is highly recommended.
This grill is designed for outdoor use only. DO
NOT use this grill inside a building, garage, or
enclosed area. DO NOT use this grill in or on a
recreational vehicle or boat.
When installing this grill in a combustible
surround, a Summerset insulating jacket/grill
liner must be used.
A minimum five (5) foot clearance is required
between the counter-top and the overhead
construction.
When installed under combustible overhead
construction, the area above the cooking
surface of the grill must be covered with an
exhaust hood. The exhaust hood provides
the protection for the combustible overhead
construction.