3
BEFORE GRILLING
SHIPMENT ARRIVING DAMAGED:
IMPORTANT NOTES:
VISIBLE DAMAGE
If your shipment arrives with visible damage to
the box/carton, be sure the damage is noted
on the bill of freight or express receipt and
signed by the person making the delivery. File
claim for damages immediately, regardless of
the extent of damage.
BE MINDFUL OF WIND DIRECTION
When selecting a suitable location, consider
important factors such as exposure to the
wind and foot traffic paerns. If you have a
freestanding grill, position it so the prevailing
wind blows into the front control panel (at
your back when grilling), allowing for proper
front to rear airow. Built-in grill located
in areas with prevailing winds should be
protected by a wind barrier, wind deflector, or
wind guard. The grill is designed to pull in air
from the front and exhaust through the rear
of the unit. Winds hiing the back of the grill
directly may cause problems. Be sure wind
doesn’t blow into the hood gap.
CONCEALED DAMAGES
If damages are unnoticed until the grill is
unpacked, notify the transportation company
or carrier immediately and file a concealed
damage claim with them. This should be done
within (5) days of the delivery date. Be sure to
hold on to the box/carton for inspection. We
cannot assume responsibility for damage or
loss incurred in transit.
GAS LINE LENGTH
Keep all gas supply lines as short as possible.
Gas lines lose pressure over distance and with
each elbow or “t” fiing added. This drop in
pressure affects grill performance.
PROPER LEVELING
PROPER LEVELING DURING INSTALLATION
IS CRITICAL. A GRILL THAT IS OUT OF LEVEL
WILL CAUSE ERRATIC BURNER COMBUSTION
AND INEFFICIENT, UNEVEN HEATING. THE
GRILL SHOULD BE LEVEL IN ALL DIRECTIONS.
ADJUSTMENTS MAY NEED TO BE MADE EACH
TIME WHEN MOVING A FREESTANDING UNIT.
CONSTRUCTION ZONES
Keep all stainless steel products away from
construction zones. Construction debris such
as (but not limited to) stone dust, stucco,
and lime dust could damage or permanently
discolor stainless steel products. Keep all
caustic chemicals including chlorine and pool
cleaning products away from stainless steel at
all times.
TESTING FOR LEAKS
Create a soapy water solution of 1 part soap
and 3 parts water. Confirm that all control
knobs are in the off position. Turn on the
fuel supply. For natural gas, turn the valve
handle ¼ turn to align with the gas flow. For
LP, turn the cylinder valve counter clockwise
one full rotation. Apply the soap solution
generously by paint brush or squirt bole on
all connections and fiings. If bubble appear
to grow on any of the connections, you have
a gas leak. IMMEDIATELY turn off the gas
supply. Wash off the soapy solution with
cold water and dry. Tighten the loose joint
or replace the faulty part with manufacturer-
recommended replacement parts. DO NOT
aempt to repair the L.P. cylinder valve if it
is damaged. The only way to safely resolve a
damaged cylinder is to replace it by calling an
authorized gas appliance service technician
or an LP gas dealer. Repeat the leak test to
ensure that no leaks are present. Do not use
the appliance until the leak is corrected.