Loading ...
Loading ...
Loading ...
38
EN
INSTALLATION INSTRUCTIONS FOR BUILT-IN
The following instructions are directed at the qualied installer, so the installation and
maintenance procedures may be followed in the most professional and expert manner.
Important: Unplug the electrical connection before performing any maintenance or
regular upkeep work.
Positioning for gas hob
Important: this unit may be installed and used only in permanently ventilated rooms.
The following requirements must be observed:
1. The room must be tted with a ventilation system which ventilates smoke and gases
from combustion to the outside of rooms.This must be done by hood or electric
ventilator.
In a chimney stack or branched ue
(exclusively for cooking appliances).
Directly to the outside.
2. The room must be allowed for the inux of the air which is for proper combustion.
The air ow for combustion purposes must not less than 2 m³/h per kW of installed
capacity. The air supply will be effected by inux from the outside through a duct, its
inner cross section is at least 100cm² and must not be blocked accidentally.
The gas hob without safety devices, to prevent ame go out accidentally, must have
a ventilation working on twice volume. For example, a minimum of 200 cm² (Fig.
3). Otherwise, the room can be vented indirectly through adjacent rooms which
is tted with ventilation ducts to the outside. Although the adjacent rooms are not
shared areas, bedrooms, but re risk is hidden(see illustration).
Loading ...
Loading ...
Loading ...