9
 Observe all governing codes and ordinances.
This installaon must conform with all local codes and
ordinances. In the absence of local codes, installaon must
conform with American Naonal Standard, Naonal Fuel Gas
Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
Naonal Fire Protecon Associaon
One Baerymarch Park, Quincy, MA 02269
CSA Internaonal
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dryer has been cered by CSA Internaonal
for use at altudes up to 10,000 feet (3048 m) above sea level
at the B.T.U. rang indicated on the model/serial plate. Burner
input adjustments are not required when the dryer is operated
up to this elevaon.
When installed above 10,000 feet (3048 m), a four percent
(4%) reducon of the burner B.T.U. rang shown on the model/
serial plate is required for each 1,000 foot (305 m) increase in
elevaon. For assistance when converng to other gas types
and/or installing above 10,000 feet (3048 m) elevaon, contact
your local service company.
Gas Supply
GAS DRYER INSTALLATION REQUIREMENTS